This test set improves the efficiency of fiber optics certification. The Taptive user interface simplifies set-up, eliminates errors and speeds troubleshooting. A set reference wizard ensures correct reference setting and eliminates negative loss errors.
This test set improves the efficiency of fiber optics certification. The Taptive user interface simplifies set-up, eliminates errors and speeds troubleshooting. A set reference wizard ensures correct reference setting and eliminates negative loss errors.
Features
Power Meter Specifications | |
Input Connector | Interchangeable connector adapter (LC standard, SC, ST and FC optional) |
Detector Type | InGaAs |
Wavelengths | 850 nm, 1300 nm, 1310 nm, 1550 nm |
Power Measurement Range | 0 dBm to -65 dBm (850 nm) 0 dBm to -70 dBm (all other wavelengths) |
Power Measurement Uncertainty1,2 | < ± 5% ± 32 pW |
Measurement Linearity | < ± 0.1 dB |
Re-calibration Period | 1 year |
Loss/Length Specifications | |
Testing Speeds (excludes referencing times) | Smart Remote mode: < 3 seconds (2 wavelengths, one direction, auto wavelength detection) Far End Source mode: ≤ 2 seconds (2 wavelengths, one direction auto wavelength detection) Loopback mode: ≤ 2 seconds (2 wavelengths, one direction auto wavelength detection) |
Input/Output Connectors | Interchangeable connector adapter (LC standard, SC, ST and FC optional) |
Launch Condition | Encircled Flux compliant to TIA-526-14-B, ISO/IEC 14763-3 and IEC 61280-4-1 |
Fiber Types Tested | 50/125 µm or 62.5/125 µm |
Source Type and Wavelengths | LED source 850 nm ± 30 nm 1300 nm ± 20 nm |
Maximum Length Measurement | 12 km |
Length Measurement Accuracy | ± 1.5 m plus ± 1 % of length |
Output Power (Nominal) | ≥ -24 dBm with EF-TRC |
Output Power Stability | ± 0.05 dB over 8 hours ± 0.03 dB over 15 minutes |
Visual Fault Locator (VFL) | |
Output Power | >-5 dBm >0 dBm Continuous wave SC/UPC connector |
Operating Wavelength | 650 nm nominal |
Output Modes | Continuous wave Pulsed mode (2 Hz to 3 Hz blink frequency) |
Connector Adapter | 2.5 mm universal |
Laser Safety | Class II CDRH Over operating temperature range |
Power Meter Specifications | |
Input Connector | Interchangeable connector adapter (LC standard, SC, ST and FC optional) |
Detector Type | InGaAs |
Wavelengths | 850 nm, 1300 nm, 1310 nm, 1550 nm |
Power Measurement Range | 0 dBm to -65 dBm (850 nm) 0 dBm to -70 dBm (all other wavelengths) |
Power Measurement Uncertainty1,2 | < ± 5% ± 32 pW |
Measurement Linearity | < ± 0.1 dB |
Re-calibration Period | 1 year |
Loss/Length Specifications | |
Testing Speeds (excludes referencing times) | Smart Remote mode: < 3 seconds (2 wavelengths, one direction, auto wavelength detection) Far End Source mode: ≤ 2 seconds (2 wavelengths, one direction auto wavelength detection) Loopback mode: ≤ 2 seconds (2 wavelengths, one direction auto wavelength detection) |
Input/Output Connectors | Interchangeable connector adapter (LC standard, SC, ST and FC optional) |
Launch Condition | Encircled Flux compliant to TIA-526-14-B, ISO/IEC 14763-3 and IEC 61280-4-1 |
Fiber Types Tested | 50/125 µm or 62.5/125 µm |
Source Type and Wavelengths | LED source 850 nm ± 30 nm 1300 nm ± 20 nm |
Maximum Length Measurement | 12 km |
Length Measurement Accuracy | ± 1.5 m plus ± 1 % of length |
Output Power (Nominal) | ≥ -24 dBm with EF-TRC |
Output Power Stability | ± 0.05 dB over 8 hours ± 0.03 dB over 15 minutes |
Visual Fault Locator (VFL) | |
Output Power | >-5 dBm >0 dBm Continuous wave SC/UPC connector |
Operating Wavelength | 650 nm nominal |
Output Modes | Continuous wave Pulsed mode (2 Hz to 3 Hz blink frequency) |
Connector Adapter | 2.5 mm universal |
Laser Safety | Class II CDRH Over operating temperature range |