An intrinsically-safe, and battery-operated 9" stick reference thermometer safe for working in indoor or outdoor environments where potentially explosive gases may be present. Features a large backlit LCD that rotates up to 90°, measures from -58 to 320°F (-50 to 160°C), and comes with data logging of up to 10,000 readings.
An intrinsically-safe, and battery-operated 9" stick reference thermometer safe for working in indoor or outdoor environments where potentially explosive gases may be present. Features a large backlit LCD that rotates up to 90°, measures from -58 to 320°F (-50 to 160°C), and comes with data logging of up to 10,000 readings.
The "Stik" thermometer provides a temperature range of -58 to 320°F (-50 to 160°C) and delivers repeatable temperature measurements accurate to ±0.09°F (±0.05°C). It is rated intrinsically safe for working in indoor or outdoor environments where potentially explosive gases may be present and is a great choice for environments that aren't potentially explosive, as well such as the floor of a processing plant. The battery-operated thermometer is ideal for daily checks of working thermometers, custody transfer temperature determination, PET calibration, LIG calibration, and temperature transmitter calibration and verification.
The stainless steel probe and digital readout are fixed together and calibrated as a system. The large backlit LCD rotates 90° degrees, making it easy to read from any angle, and the user-configurable stability/trend indicator lets you know when your temperature is stable enough to record an accurate measurement. A user-settable auto-off function extends typical battery life to up to 300 hours, and the low-battery indicator and stop-measure function prevent erroneous measurements from being made due to a low battery. Plus you can easily and accurately calibrate it with a simple three-point calibration function.
Features
Temperature Range | -58 to 320°F (-50 to 160°C) |
Accuracy (1 Year) | ±0.09°F (±0.05°C) |
Temperature Resolution | Selectable: 0.1, 0.01, 0.001 (default 0.01) |
Sample Rate | Selectable: 0.5 seconds, 1 seconds, 2 seconds (default 1 second) |
Readout Temperature Coefficient | Add ±10 ppm/°C of full scale temperature from 14 to 64°F (−10 to 18°C) and 82 to 122°F (28 to 50°C) |
Probe Temperature Coefficient | 0.00385 Ω/Ω/°C Nominal |
Nominal Probe Resistance at 0°C | 100 Ω |
Probe Hysteresis | ±0.01°C |
Response time | 14 seconds |
Operating Temperature Range Readout | 14 to 122°F (-10 to 50°C) |
Storage Temperature | -4 to 140°F (-20 to 60°C) 0 to 95% RH, non-Condensing |
Display Units | °C, °F |
Sensor | Type: 100 Ω thin-film RTD Length: ≤0.4" (10 mm) Position (from sheath tip): 0.1" (3 mm) |
Minimum Immersion Depth | Wet medium (liquid bath, thermowell with thermal compound) 2.8" (70 mm) Dry medium (dry-well, thermowell without thermal compound) 4.8" (120 mm) |
Maximum Immersion Depth | 2" (50 mm) less than the total length. Make sure the last 50 mm of probe, nearest to the internal electronics of the device, are not put into the heat source |
Probe Sheath Material | Stainless steel |
Data Logging | Up to 10,000 time-stamped readings stored to internal memory |
Logging Intervals | 2 seconds, 5 seconds, 10 seconds, 30 seconds, or 60 seconds |
Damping | Moving average of the most recent 2 to 10 readings (ON/OFF, 2, 5, 10) |
Communications | RS-232 stereo jack (access calibration parameters only) |
DC Power | 3 x AAA batteries, typical battery life of 300 hours without LCD backlight |
Battery Life | Approximately 300 hours (12.5 days) of continuous operation with the backlight off |
Battery Save (Auto-Off) Range | Selectable from 1 to 30 minutes or can be disabled |
Safety | IEC 60079-0, IEC 60079-11: Ex ib IIB T4 Gb; IEC 61010-1: Pollution Degree 2 |
Electromagnetic Compatibility | International: IEC 61326-1: Portable Equipment; IEC 61326-2-2; CISPR 11: Group 1, Class B USA (FCC): 47 CFR 15 subpart B. This product is considered an exempt device per clause 15.103 |
Dimensions | 5 x 2.5 x 1.4" (125 x 62 x 35 mm) |
Probe Size | 3/16 x 9" (4.8 x 229 mm) |
Weight | 6.9 oz (196 g) |
Click on a category to view a selection of compatible accessories with the Fluke 1551A-9-DL Intrinsically Safe Stik Thermometer with data logging, 9", -58 to 320°F.
Temperature Range | -58 to 320°F (-50 to 160°C) |
Accuracy (1 Year) | ±0.09°F (±0.05°C) |
Temperature Resolution | Selectable: 0.1, 0.01, 0.001 (default 0.01) |
Sample Rate | Selectable: 0.5 seconds, 1 seconds, 2 seconds (default 1 second) |
Readout Temperature Coefficient | Add ±10 ppm/°C of full scale temperature from 14 to 64°F (−10 to 18°C) and 82 to 122°F (28 to 50°C) |
Probe Temperature Coefficient | 0.00385 Ω/Ω/°C Nominal |
Nominal Probe Resistance at 0°C | 100 Ω |
Probe Hysteresis | ±0.01°C |
Response time | 14 seconds |
Operating Temperature Range Readout | 14 to 122°F (-10 to 50°C) |
Storage Temperature | -4 to 140°F (-20 to 60°C) 0 to 95% RH, non-Condensing |
Display Units | °C, °F |
Sensor | Type: 100 Ω thin-film RTD Length: ≤0.4" (10 mm) Position (from sheath tip): 0.1" (3 mm) |
Minimum Immersion Depth | Wet medium (liquid bath, thermowell with thermal compound) 2.8" (70 mm) Dry medium (dry-well, thermowell without thermal compound) 4.8" (120 mm) |
Maximum Immersion Depth | 2" (50 mm) less than the total length. Make sure the last 50 mm of probe, nearest to the internal electronics of the device, are not put into the heat source |
Probe Sheath Material | Stainless steel |
Data Logging | Up to 10,000 time-stamped readings stored to internal memory |
Logging Intervals | 2 seconds, 5 seconds, 10 seconds, 30 seconds, or 60 seconds |
Damping | Moving average of the most recent 2 to 10 readings (ON/OFF, 2, 5, 10) |
Communications | RS-232 stereo jack (access calibration parameters only) |
DC Power | 3 x AAA batteries, typical battery life of 300 hours without LCD backlight |
Battery Life | Approximately 300 hours (12.5 days) of continuous operation with the backlight off |
Battery Save (Auto-Off) Range | Selectable from 1 to 30 minutes or can be disabled |
Safety | IEC 60079-0, IEC 60079-11: Ex ib IIB T4 Gb; IEC 61010-1: Pollution Degree 2 |
Electromagnetic Compatibility | International: IEC 61326-1: Portable Equipment; IEC 61326-2-2; CISPR 11: Group 1, Class B USA (FCC): 47 CFR 15 subpart B. This product is considered an exempt device per clause 15.103 |
Dimensions | 5 x 2.5 x 1.4" (125 x 62 x 35 mm) |
Probe Size | 3/16 x 9" (4.8 x 229 mm) |
Weight | 6.9 oz (196 g) |