Combines the capabilities of a safety-rated digital multimeter and mA loop calibrator into one tool. This process meter is ideal for troubleshooting and calibrating current loop applications due to its ability to measure, source and simulate mA. This value-added kit includes the REED R2300 Infrared Thermometer and the REED R9999 Industrial Tool Bag for FREE.
Combines the capabilities of a safety-rated digital multimeter and mA loop calibrator into one tool. This process meter is ideal for troubleshooting and calibrating current loop applications due to its ability to measure, source and simulate mA. This value-added kit includes the REED R2300 Infrared Thermometer and the REED R9999 Industrial Tool Bag for FREE.
Features
Applications
REED R2300 Infrared Thermometer, 12:1, 752°F (400°C)
This infrared thermometer features a 12:1 distance to spot ratio and is capable of measuring temperatures up to 752°F (400°C). The R2300 is an affordable non-contact measurement solution able to quickly and efficiently measure the temperature of hot, hazardous or hard-to reach objects from a safe distance.
Features
Applications
REED R9999 Industrial Tool Bag
Features
V DC | |
Range and Resolution | 400.0 mV, 4.000 V, 40.00 V, 400.0 V, 1000 V |
Best Accuracy (% of Reading + LSD) | 0.1% + 1 |
V AC (True RMS) | |
Range and Resolution | 400.0 mV, 4.000 V, 40.00 V, 400.0 V, 1000 V |
Best Accuracy (% of Reading + LSD) | 0.7% + 2 |
mA DC | |
Range and Resolution | 30.000 mA |
Best Accuracy (% of Reading + LSD) | 0.05% + 2 |
mA DC | |
Range and Resolution | 30.000 mA |
Best Accuracy (% of Reading + LSD) | 0.05% + 2 |
A DC | |
Range and Resolution | 1.000 A (0.440 A continuous) |
Best Accuracy (% of Reading + LSD) | 0.2% + 2 |
A AC | |
Range and Resolution | 1.000 A (0.440 A continuous) |
Best Accuracy (% of Reading + LSD) | 1% + 2 |
Resistance | |
Range and Resolution | 400.0 Ohms, 4.000 k, 40.00 k, 400.0 k, 4.0 M, 40 M |
Best Accuracy (% of Reading + LSD) | 0.2% + 1 |
Frequency (0.5 Hz to 20 kHz) | |
Range and Resolution | 199.99 Hz, 1999.9 Hz, 19.999 kHz |
Best Accuracy (% of Reading + LSD) | 0.005% + 1 |
Diode Test | |
Range and Resolution | 2.000 V (shows diode voltage drop) |
Best Accuracy (% of Reading + LSD) | 2% + 1 |
Continuity | |
Range and Resolution | Beeps for resistance <approx. 100 Ω |
DC Current Output (Internal Battery Operation) | |
Range and Resolution | 0.000 to 20.000 mA or 4.000 to 20.000 mA, (selectable at power-up) Over-range to 24.000 mA |
Drive Capability | 24 V compliance or, 1,200 ohms, at 20 mA |
Accuracy (% of Span) | 0.05% |
DC Current Simulate (Ext. 15 to 48 V Loop Supply) | |
Range and Resolution | 0.000 to 20.000 mA or 4.000 to 20.000 mA, (selectable at power-up) Over-range to 24.000 mA |
Drive Capability | 1000 ohms, at 20 mA |
Accuracy (% of Span) | 0.05% |
Current Adjustment Modes | |
Manual | Coarse, Fine, 25% and 100% step |
Automatic | Slow Ramp, Fast Ramp, 25% step |
General Specifications | |
Maximum Voltage Applied Between any Jack and Earth Ground | 1000 V RMS |
Storage Temperature | -40 to 140°F (-40 to 60°C) |
Operating Temperature | -4 to 131°F (-20 to 55°C) |
Temperature Coefficient | 0.05 x (specified accuracy) per °C (for temperatures <18°C or >28°C) |
Relative Humidity | 95% up to 86°F (30°C) 75% up to 104°F (40°C) 45% up to 122°F (50°C) 35% up to 131°F (55°C) |
Vibration | Random, 2 g, 5 to 500 Hz |
Shock | 3.3' (1 m) drop test |
Battery | 4 x AA Alkaline batteries |
Battery Life | 140 hours typical (measurement), 10 hours typical (sourcing 12 mA) |
Dimensions | 1.97 x 3.94 x 8" (50 x 100 x 203 mm) |
Weight | 1.3 lbs (600 g) |
Safety | IEC61010-1, Pollution Degree 2/IEC61010-2-033, CAT IV 600 V/CAT III 1000 V |
Precision 1000V, 440mA True RMS digital Multimeter. 0.1% DC Voltage accuracy.
Fast responding entry-level infrared thermometer with min/max temperature readings and adjustable high/low temperature alarms.
Case is black and blue polyester with plastic injection logo. Outside Dimensions (LxWxH): 15.8 x 7.8 x 11.8" (400 x 200 x 300mm).
Click on a category to view a selection of compatible accessories with the Fluke 787B ProcessMeter Kit - Includes FREE Products with Purchase.
V DC | |
Range and Resolution | 400.0 mV, 4.000 V, 40.00 V, 400.0 V, 1000 V |
Best Accuracy (% of Reading + LSD) | 0.1% + 1 |
V AC (True RMS) | |
Range and Resolution | 400.0 mV, 4.000 V, 40.00 V, 400.0 V, 1000 V |
Best Accuracy (% of Reading + LSD) | 0.7% + 2 |
mA DC | |
Range and Resolution | 30.000 mA |
Best Accuracy (% of Reading + LSD) | 0.05% + 2 |
mA DC | |
Range and Resolution | 30.000 mA |
Best Accuracy (% of Reading + LSD) | 0.05% + 2 |
A DC | |
Range and Resolution | 1.000 A (0.440 A continuous) |
Best Accuracy (% of Reading + LSD) | 0.2% + 2 |
A AC | |
Range and Resolution | 1.000 A (0.440 A continuous) |
Best Accuracy (% of Reading + LSD) | 1% + 2 |
Resistance | |
Range and Resolution | 400.0 Ohms, 4.000 k, 40.00 k, 400.0 k, 4.0 M, 40 M |
Best Accuracy (% of Reading + LSD) | 0.2% + 1 |
Frequency (0.5 Hz to 20 kHz) | |
Range and Resolution | 199.99 Hz, 1999.9 Hz, 19.999 kHz |
Best Accuracy (% of Reading + LSD) | 0.005% + 1 |
Diode Test | |
Range and Resolution | 2.000 V (shows diode voltage drop) |
Best Accuracy (% of Reading + LSD) | 2% + 1 |
Continuity | |
Range and Resolution | Beeps for resistance <approx. 100 Ω |
DC Current Output (Internal Battery Operation) | |
Range and Resolution | 0.000 to 20.000 mA or 4.000 to 20.000 mA, (selectable at power-up) Over-range to 24.000 mA |
Drive Capability | 24 V compliance or, 1,200 ohms, at 20 mA |
Accuracy (% of Span) | 0.05% |
DC Current Simulate (Ext. 15 to 48 V Loop Supply) | |
Range and Resolution | 0.000 to 20.000 mA or 4.000 to 20.000 mA, (selectable at power-up) Over-range to 24.000 mA |
Drive Capability | 1000 ohms, at 20 mA |
Accuracy (% of Span) | 0.05% |
Current Adjustment Modes | |
Manual | Coarse, Fine, 25% and 100% step |
Automatic | Slow Ramp, Fast Ramp, 25% step |
General Specifications | |
Maximum Voltage Applied Between any Jack and Earth Ground | 1000 V RMS |
Storage Temperature | -40 to 140°F (-40 to 60°C) |
Operating Temperature | -4 to 131°F (-20 to 55°C) |
Temperature Coefficient | 0.05 x (specified accuracy) per °C (for temperatures <18°C or >28°C) |
Relative Humidity | 95% up to 86°F (30°C) 75% up to 104°F (40°C) 45% up to 122°F (50°C) 35% up to 131°F (55°C) |
Vibration | Random, 2 g, 5 to 500 Hz |
Shock | 3.3' (1 m) drop test |
Battery | 4 x AA Alkaline batteries |
Battery Life | 140 hours typical (measurement), 10 hours typical (sourcing 12 mA) |
Dimensions | 1.97 x 3.94 x 8" (50 x 100 x 203 mm) |
Weight | 1.3 lbs (600 g) |
Safety | IEC61010-1, Pollution Degree 2/IEC61010-2-033, CAT IV 600 V/CAT III 1000 V |
Precision 1000V, 440mA True RMS digital Multimeter. 0.1% DC Voltage accuracy.
Fast responding entry-level infrared thermometer with min/max temperature readings and adjustable high/low temperature alarms.
Case is black and blue polyester with plastic injection logo. Outside Dimensions (LxWxH): 15.8 x 7.8 x 11.8" (400 x 200 x 300mm).
Click on a category to view a selection of compatible accessories with the Fluke 787B ProcessMeter Kit - Includes FREE Products with Purchase.