The Shark 100 meter is equipped with EIG's exclusive V-Switch technology. This V3 model measures Volts, Amps, kW, kVAR, PF, kVA, Freq, kWh, kVAh, kVARh and DNP 3.0 and communicates via WiFi connection.
The Shark 100 meter is equipped with EIG's exclusive V-Switch technology. This V3 model measures Volts, Amps, kW, kVAR, PF, kVA, Freq, kWh, kVAh, kVARh and DNP 3.0 and communicates via WiFi connection.
Discontinued!
This product has been discontinued and is no longer available. There is no direct replacement. Don't worry, we have some options to help you find what you need:
Visit our Panel Meters category for similar products.
Or let's do a search and help you find what you need:
Designed to address the most demanding applications, the Shark 100s surpasses others providing advanced performance metering in a low cost, compact, panel meter design. Based on an all new platform, this meter significantly outperforms other devices many times its price. This unit is perfect for new metering applications and for a simple replacement to existing analog meters.
The unit utilizes high speed DSP technology with high resolution A/D conversion to provide revenue certifiable accuracy for Utility Billing, Substation Metering, Sub-metering and Critical Metering applications.
The Shark 100 was engineered to be as easy to use and install as possible. From user interface to mechanical construction, many hours were spent to make the Shark straightforward and intuitive so an installer with minimal meter experience and training can succeed with the product. Shark is programmed using a PDA, a PC Computer or through a simple keypad interface. By using the PC or PDA, a technician or electrician can see a visual phasor diagram of the vectors insuring that CT and Voltage polarities are correct. All inputs are color coordinated and have clear simple to understand labeling to avoid cross wiring mistakes.
There are also two communications ports available on the Shark100s - One port provides RS485 communication speaking Modbus ASCII or Modbus RTU protocol.(9600 - 57,600 baud) and a second IrDA port is available for remote setup, polling and reading. DNP 3.0 protocol is also included with V-Switch packages V3 and V4.
The Shark 100s is equipped with EIG's exclusive V-Switch® Technology. V-Switch®, virtual switch technology allows users, OEMs or Power Utilities to minimize different levels of meters and reduce stocking to one type of hardware. As such V-Switch measurement options can be selected at time of purchase.
Features
Electro Industries/GaugeTech introduces industry leading metering technology. Designed to address the most demanding applications, the Shark 100 surpasses others providing advanced performance metering in a low cost, compact, panel meter design. Based on an all new platform, this meter significantly outperforms other devices many times its price. This unit is perfect for new metering applications and for a simple replacement to existing analog meters.
The unit utilizes high speed DSP technology with high resolution A/D conversion to provide revenue certifiable accuracy for Utility Billing, Substation Metering, Sub-metering and Critical Metering applications.
New V-Switch® Technology
The Shark 100 is equipped with EIG's exclusive V-Switch® Technology. V-Switch®, virtual switch technology allows users, OEMs or Power Utilities to minimize different levels of meters and reduce stocking to one type of hardware. In this manner, the meter can be expanded to meet the specific application even after installation. Using V-Switches, you can purchase what you require now and field upgrade functionality as needed, which allows you to optimize your investment. Advanced versions of the Shark 100 (V3 and V4) also include DNP 3.0 communication protocol.
Accuracy percentage of Voltage L-N, Voltage L-L, and Current is 0.1%. For Watts, Wh, VARs, VARh, VA, Vah, and PF the accuracy is 0.2%. Accuracy for Frequency is 0.01 Hz, %THD is 1%, and for % load bar 1-120% readings.
The Shark 100 is a traceable revenue meter, that contains a utility grade test pulse allowing power providers to verify and confirm that the meter is performing to its rated accuracy.
Available V-Switches
Easy to Use and Install
The Shark 100 was engineered to be as easy to use and install as possible. From user interface to mechanical construction, many hours were spent to make the Shark straightforward and intuitive so an installer with minimal meter experience and training can succeed with the product. Shark is programmed using a PDA, a PC Computer or through a simple keypad interface. By using the PC or PDA, a technician or electrician can see a visual phasor diagram of the vectors insuring that CT and Voltage polarities are correct. All inputs are color coordinated and have clear simple to understand labeling to avoid cross wiring mistakes.
Advanced Communication Capability with IrDA Interface
Superior Voltage and Current Inputs
Utility Peak Demand Metering
The Shark 100 provides user configured fixed window or rolling window demand. This all you to set up the particular utility demand profile. A Fixed window demand is the demand used over a user configured demand period (usually 5, 15 or 30 minutes). A rolling window demand is a fixed window demand that moves for a user specified sub-interval period. An example is would be a 15 minute demand using 3 sub-interval provides a new demand reading every 5 minutes based on the last 15 minutes. Readings for kW, kVAR, kVA and PF are calculated using utility demand features. All other parameters offer max and min capability over the user selectable averaging period. Voltage provides an instantaneous max and min reading displaying the highest surge and lowest sag seen by the meter.
Physical Configuration
The unit mounts directly in an ANSI C39.1 (4" Round form) and an IEC 92 mm DIN square form. This is perfect for new installations and for existing panels. In new installations, simply use existing DIN or ANSI punches. For existing panels, pull out old analog meters and place this meter in its place. The meter uses standard voltage and current inputs so that CT and PT wiring does not need to be replaced.
Applications
Voltage | |
Inputs | 0-416 Volts Line To Neutral, 0-721 Volts Line to Line
Universal Voltage Input |
Input Withstand Capability | Meets IEEE C37.90.1 (Surge Withstand Capability) |
Programmable Voltage Range | Any PT ratio |
Supports | 3 Element WYE, 2.5 Element WYE, 2 Element Delta, 4 Wire Delta Systems |
Burden | 0.36VA per phase Max at 600V, 0.014VA at 120 Volts |
Input wire gauge max | AWG 12 / 2.5mm2 |
Current | |
Class 10 | (0 to 11) A, 5 Amp Nominal |
Class 2 | (0 to 2) A, 1A Nominal Secondary |
Fault Current Withstand | 100 Amps for 10 Seconds, 300 Amps for 3 Seconds, 500 Amps for 1 Second |
Programmable Current | Any CT Ratio |
Burden | 0.005VA per phase Max at 11Amps |
Pickup Current | 5 mA |
Pass through wire gauge dimension | 0.177" (4.5 mm) |
Voltage | |
Inputs | 0-416 Volts Line To Neutral, 0-721 Volts Line to Line
Universal Voltage Input |
Input Withstand Capability | Meets IEEE C37.90.1 (Surge Withstand Capability) |
Programmable Voltage Range | Any PT ratio |
Supports | 3 Element WYE, 2.5 Element WYE, 2 Element Delta, 4 Wire Delta Systems |
Burden | 0.36VA per phase Max at 600V, 0.014VA at 120 Volts |
Input wire gauge max | AWG 12 / 2.5mm2 |
Current | |
Class 10 | (0 to 11) A, 5 Amp Nominal |
Class 2 | (0 to 2) A, 1A Nominal Secondary |
Fault Current Withstand | 100 Amps for 10 Seconds, 300 Amps for 3 Seconds, 500 Amps for 1 Second |
Programmable Current | Any CT Ratio |
Burden | 0.005VA per phase Max at 11Amps |
Pickup Current | 5 mA |
Pass through wire gauge dimension | 0.177" (4.5 mm) |