Eagle Eye HGD-2000 Hydrogen Gas Detector

Model: HGD-2000

Eagle Eye HGD-2000 Hydrogen Gas Detector

Model: HGD-2000

Monitor hydrogen gas buildup in storage rooms and facilities that house batteries with this hydrogen gas detector. Easy-to-use and easy-to-install, this detector has a terminal block to connect to single-phase AC power sources and two internal relays to switch a remote exhaust fan and/or alarm on and off.

Monitor hydrogen gas buildup in storage rooms and facilities that house batteries with this hydrogen gas detector. Easy-to-use and easy-to-install, this detector has a terminal block to connect to single-phase AC power sources and two internal relays to switch a remote exhaust fan and/or alarm on and off.

Discontinued!

This product has been discontinued and is no longer available.

There is no direct replacement, however we recommend the:

Eagle Eye HGD-2000 Hydrogen Gas Detector, DC Version-

Eagle Eye HGD-2000 Hydrogen Gas Detector, DC Version

Model: HGD-2000 DC | Order No: HGD-2000 (DC)

Used to monitor hydrogen gas buildup in storage rooms and facilities that house batteries. Very easy-to-use and easy-to-install.


Eagle Eye HGD-2000AC Hydrogen and Combustible Gas Detector-

Eagle Eye HGD-2000AC Hydrogen and Combustible Gas Detector

Model: HGD-2000 AC | Order No: HGD-2000 (AC)

Monitors hydrogen gas buildup in storage rooms and facilities that house batteries with a terminal block for connection to a single-phase AC power source and two internal relays.


Not what you're looking for? Let’s do a search and help you find what you need.


Eagle Eye HGD-2000 Offers

Features

  • Automatic operation and continuous 24/7 monitoring
  • High sensitivity and stability
  • Long life-span for reliable monitoring
  • 12 V DC operation voltage
  • Inexpensive protection for equipment and personnel
  • Save electricity, heating, and air conditioning costs by not continuously running exhaust fans
  • Save insurance costs - reduce insurance premiums when placed in battery charging rooms
  • Compliance with IEEE Std 450
  • Compliance with National Fire Protection Agency (NFPA) Article 64
  • Compliance with Uniform Building Code (UBC) Section 6400

Applications

  • Utilities and power plants
  • UPS power systems
  • Fuel cell test stations
  • Nuclear waste reforming
  • Hydrogen refuelling stations
  • Construction and maintenance facilities
  • Fire department
  • Battery suppliers
  • Motive power
  • Golf cart
  • Eagle Eye HGD-2000 Specifications

    Alarm Relay 2 x form C contacts provided, user-configurable connections
    Mounting 4 x 3/16" (4.5 mm) screws
    Operating Environment 14 to 104°F (-10 to 40°C)
    Power Requirements 85 to 265 VAC, 50/60 Hz
    Dimensions 7 x 4.75 x 2.5" (178 x 120 x 55 mm)
    Click here for complete specifications on the Eagle Eye HGD-2000

    What's included with the Eagle Eye HGD-2000

    • Hydrogen Gas Detector
    • User's Manual

    Click on a category to view a selection of compatible accessories with the Eagle Eye HGD-2000 Hydrogen Gas Detector.

    Eagle Eye HGD-RB Remote Box, 25" Cable HGD-RB
    For use with HGD Gas Detector Series.




    Eagle Eye HGD-MC 25' Module Cable For HGD-Series HGD-MC
    25' modular cable for HGD-2000 remote box.




    Eagle Eye HGD-TR Test & Recalibrate Sensor Board HGD-TR
    For use with HGD Gas Detector Series.




    Eagle Eye HGD-SB Sensor Board HGD-SB
    For use with HGD Gas Detector Series.




    Ask a question about Eagle Eye HGD-2000 Hydrogen Gas Detector

    Customer Reviews for the Eagle Eye HGD-2000

    Eagle Eye HGD-2000 Offers

    Features

    • Automatic operation and continuous 24/7 monitoring
    • High sensitivity and stability
    • Long life-span for reliable monitoring
    • 12 V DC operation voltage
    • Inexpensive protection for equipment and personnel
    • Save electricity, heating, and air conditioning costs by not continuously running exhaust fans
    • Save insurance costs - reduce insurance premiums when placed in battery charging rooms
    • Compliance with IEEE Std 450
    • Compliance with National Fire Protection Agency (NFPA) Article 64
    • Compliance with Uniform Building Code (UBC) Section 6400

    Applications

  • Utilities and power plants
  • UPS power systems
  • Fuel cell test stations
  • Nuclear waste reforming
  • Hydrogen refuelling stations
  • Construction and maintenance facilities
  • Fire department
  • Battery suppliers
  • Motive power
  • Golf cart
  • Eagle Eye HGD-2000 Specifications

    Alarm Relay 2 x form C contacts provided, user-configurable connections
    Mounting 4 x 3/16" (4.5 mm) screws
    Operating Environment 14 to 104°F (-10 to 40°C)
    Power Requirements 85 to 265 VAC, 50/60 Hz
    Dimensions 7 x 4.75 x 2.5" (178 x 120 x 55 mm)
    Click here for complete specifications on the Eagle Eye HGD-2000

    What's included with the Eagle Eye HGD-2000

    • Hydrogen Gas Detector
    • User's Manual

    Click on a category to view a selection of compatible accessories with the Eagle Eye HGD-2000 Hydrogen Gas Detector.

    Eagle Eye HGD-RB Remote Box, 25" Cable HGD-RB
    For use with HGD Gas Detector Series.




    Eagle Eye HGD-MC 25' Module Cable For HGD-Series HGD-MC
    25' modular cable for HGD-2000 remote box.




    Eagle Eye HGD-TR Test & Recalibrate Sensor Board HGD-TR
    For use with HGD Gas Detector Series.




    Eagle Eye HGD-SB Sensor Board HGD-SB
    For use with HGD Gas Detector Series.




    Ask a question about Eagle Eye HGD-2000 Hydrogen Gas Detector

    Customer Reviews for the Eagle Eye HGD-2000

    More Eagle Eye Products

    Calibration Lab