For use with general-purpose melt pressure measurements, this melt pressure sensor works with DCS and PLCs and provides the industry standard 0 to 10 Vdc amplified signal. Come with a snout length of 6" (15 cm).
For use with general-purpose melt pressure measurements, this melt pressure sensor works with DCS and PLCs and provides the industry standard 0 to 10 Vdc amplified signal. Come with a snout length of 6" (15 cm).
General purpose melt pressure transducer provides the industry standard 3.33 mV/V signal compatible with most pressure indicators. Designed to be widely acceptable by OEMs and users anywhere in the world.
Features
Output | 3.33 mV/V ±2.0% |
Input Voltage | 10 vdc recommended, 12 vdc maximum |
Combined Error | ±1.0% FSO, (Including Linearity, Repeatability & Hysteresis) |
Repeatability | ±0.2%FSO |
Configuration | Four-arm bonded foil Wheatstone bridge strain gage |
Bridge Resistance | Input & Output: 345 Ohms minimum |
Over Pressure | 2 X FSO |
Zero Balance | ±10% FSO |
Internal Shunt Calibration (R-Cal) | 80% FSO ±1% |
Insulation Resistance | 1000 megohms @ 50 Vdc |
Output | 3.33 mV/V ±2.0% |
Input Voltage | 10 vdc recommended, 12 vdc maximum |
Combined Error | ±1.0% FSO, (Including Linearity, Repeatability & Hysteresis) |
Repeatability | ±0.2%FSO |
Configuration | Four-arm bonded foil Wheatstone bridge strain gage |
Bridge Resistance | Input & Output: 345 Ohms minimum |
Over Pressure | 2 X FSO |
Zero Balance | ±10% FSO |
Internal Shunt Calibration (R-Cal) | 80% FSO ±1% |
Insulation Resistance | 1000 megohms @ 50 Vdc |