FREE SHIPPING ON ONLINE ORDERS OVER $99*

Dwyer 626-08-CB-P1-E5-S1 Pressure Transmitter (0-30 psig) with 0.25% f.s. Accuracy & Conduit Box Housing

Model: 626-08-CB-P1-E5-S1

Dwyer 626-08-CB-P1-E5-S1 Pressure Transmitter (0-30 psig) with 0.25% f.s. Accuracy & Conduit Box Housing

Model: 626-08-CB-P1-E5-S1

Highly precise 0.25% piezo-resistive sensor contained in a compact, rugged, NEMA 4X stainless steel general purpose housing or cast aluminum conduit housing. Available in ranges of vacuum, compound to 5000 psi with a variety of optional outputs.

Highly precise 0.25% piezo-resistive sensor contained in a compact, rugged, NEMA 4X stainless steel general purpose housing or cast aluminum conduit housing. Available in ranges of vacuum, compound to 5000 psi with a variety of optional outputs.

Sale Price $226.60 USD
Regular Price $242.35 USD
Availability 1 in Stock
Quantity

Traceable In-House Calibration Certificate for your Dwyer 626-08-CH-P1-E5-S1

Traceable In-House Calibration Certificate for your Dwyer 626-08-CH-P1-E5-S1

Dwyer 626-08-CB-P1-E5-S1 Offers

Features

  • NEMA 4X rated enclosure
  • Robust 316L SS oil filled sensor
  • CE Approved Design
  • 0.25% FS (626), 1.0% FS (628)

Applications

  • Booster stations
  • Pumping systems
  • Irrigation equipment
  • PTO systems
  • Submersible pump control

Dwyer 626-08-CB-P1-E5-S1 Specifications

Service Compatible gases and liquids
Wetted Materials Type 316L SS
Accuracy 626: 0.25% FS, 0.20% RSS
628: 1.0% FS, 0.5% RSS
626 Absolute Ranges: 0.5% FS, 0.30% RSS (includes linearity, hysteresis, and repeatability)
Temperature Limit 0 to 200°F (-18 to 93°C)
Compensated Temperature Range 0 to 175°F (-18 to 79°C)
Thermal Effect ±0.2% FS/°F (includes zero and span)
Display Optional 4½ digit LCD field attachable display
Power Requirement 10 to 30 VDC (for 4 to 20 mA, 0 to 5, 1 to 5, VDC outputs)
13 to 30 VDC (for 0 to 10 VDC output)
5 VDC ±0.5 VDC (for 0.5 to 4.5 VDC ratio metric output), 10 to 35 VDC (for 4 to 20 mA with -CB option)
13 to 35 VDC or isolated 16 to 33 VAC (for selectable output with -CB option)
Output Signal 4 to 20 mA, 0 to 5 VDC, 1 to 5 VDC, 0 to 10 VDC, or 0.5 to 4.5 VDC, or selectable 0 to 5, 1 to 5, 0 to 10, 2 to 10 VDC for -CB option
Response Time 300 ms
Loop Resistance 0 to 1000 Ω max. R max = 50 (Vps-10) Ω (4 to 20 mA output)
0 to 1250 Ω max. Rmax = 50(Vps-10) Ω (4 to 20 mA output with -CB option)
5 KΩ (0 to 5, 1 to 5, 0 to 10, 0.5 to 4.5 VDC output)
Stability 1.0% FS/year (typical)
Current Consumption 38 mA maximum (for 4 to 20 mA output)
10 mA maximum (for 0 to 5, 1 to 5, 0 to 10, 0.5 to 4.5 VDC output)
140 mA maximum (for all 626/628/629-CH with optional LED)
Electrical Connections Conduit housing (-CH): Terminal block, ½" female NPT conduit
General purpose housing (-GH): Cable DIN EN 175801-803-C
Process Connections ¼" male or female NPT and BSPT
Enclosure Rating NEMA 4X (IP66)
Weight 10 oz (283 g)
Agency Approvals Standard: CE; Optional: NSF/ANSI 61/372, ANSI/UL 218, ANSI/UL 508, NEPA 20
Click here for complete specifications on the Dwyer 626-08-CB-P1-E5-S1

What's included with the Dwyer 626-08-CB-P1-E5-S1

  • Either 626 or 628 Industrial Pressure Transmitter

Ask a question about Dwyer 626-08-CB-P1-E5-S1 Pressure Transmitter (0-30 psig) with 0.25% f.s. Accuracy & Conduit Box Housing

Customer Reviews for the Dwyer 626-08-CB-P1-E5-S1

Dwyer 626-08-CB-P1-E5-S1 Offers

Features

  • NEMA 4X rated enclosure
  • Robust 316L SS oil filled sensor
  • CE Approved Design
  • 0.25% FS (626), 1.0% FS (628)

Applications

  • Booster stations
  • Pumping systems
  • Irrigation equipment
  • PTO systems
  • Submersible pump control

Dwyer 626-08-CB-P1-E5-S1 Specifications

Service Compatible gases and liquids
Wetted Materials Type 316L SS
Accuracy 626: 0.25% FS, 0.20% RSS
628: 1.0% FS, 0.5% RSS
626 Absolute Ranges: 0.5% FS, 0.30% RSS (includes linearity, hysteresis, and repeatability)
Temperature Limit 0 to 200°F (-18 to 93°C)
Compensated Temperature Range 0 to 175°F (-18 to 79°C)
Thermal Effect ±0.2% FS/°F (includes zero and span)
Display Optional 4½ digit LCD field attachable display
Power Requirement 10 to 30 VDC (for 4 to 20 mA, 0 to 5, 1 to 5, VDC outputs)
13 to 30 VDC (for 0 to 10 VDC output)
5 VDC ±0.5 VDC (for 0.5 to 4.5 VDC ratio metric output), 10 to 35 VDC (for 4 to 20 mA with -CB option)
13 to 35 VDC or isolated 16 to 33 VAC (for selectable output with -CB option)
Output Signal 4 to 20 mA, 0 to 5 VDC, 1 to 5 VDC, 0 to 10 VDC, or 0.5 to 4.5 VDC, or selectable 0 to 5, 1 to 5, 0 to 10, 2 to 10 VDC for -CB option
Response Time 300 ms
Loop Resistance 0 to 1000 Ω max. R max = 50 (Vps-10) Ω (4 to 20 mA output)
0 to 1250 Ω max. Rmax = 50(Vps-10) Ω (4 to 20 mA output with -CB option)
5 KΩ (0 to 5, 1 to 5, 0 to 10, 0.5 to 4.5 VDC output)
Stability 1.0% FS/year (typical)
Current Consumption 38 mA maximum (for 4 to 20 mA output)
10 mA maximum (for 0 to 5, 1 to 5, 0 to 10, 0.5 to 4.5 VDC output)
140 mA maximum (for all 626/628/629-CH with optional LED)
Electrical Connections Conduit housing (-CH): Terminal block, ½" female NPT conduit
General purpose housing (-GH): Cable DIN EN 175801-803-C
Process Connections ¼" male or female NPT and BSPT
Enclosure Rating NEMA 4X (IP66)
Weight 10 oz (283 g)
Agency Approvals Standard: CE; Optional: NSF/ANSI 61/372, ANSI/UL 218, ANSI/UL 508, NEPA 20
Click here for complete specifications on the Dwyer 626-08-CB-P1-E5-S1

What's included with the Dwyer 626-08-CB-P1-E5-S1

  • Either 626 or 628 Industrial Pressure Transmitter

Ask a question about Dwyer 626-08-CB-P1-E5-S1 Pressure Transmitter (0-30 psig) with 0.25% f.s. Accuracy & Conduit Box Housing

Customer Reviews for the Dwyer 626-08-CB-P1-E5-S1

More Dwyer Products

Calibration Lab