FREE SHIPPING ON ONLINE ORDERS OVER $99*

Dwyer 616D-4 Differential Pressure Transmitter (0-20"w.c.)

Model: 616D-4

Dwyer 616D-4 Differential Pressure Transmitter (0-20"w.c.)

Model: 616D-4

Senses the pressure of air and compatible gases and sends a standard 4-20 mA output signal. Specifically designed to mount on a 35 mm DIN rail in a panel.

Senses the pressure of air and compatible gases and sends a standard 4-20 mA output signal. Specifically designed to mount on a 35 mm DIN rail in a panel.

Sale Price $205.19 USD
Regular Price $219.45 USD
Availability 1 to 2 Weeks
Quantity

Traceable In-House Calibration Certificate for your Dwyer 616D-4 Differential Pressure Transmitter (0-20"w.c.)

Traceable In-House Calibration Certificate for your Dwyer 616D-4 Differential Pressure Transmitter (0-20"w.c.)

Dwyer 616D-4 PRESSURE TRANSMITTER, DIN RAIL, 0/20

  • Mounting style allows for several units to be mounted closely together reducing required space.
  • A wide range of models are available factory calibrated to specific ranges.
  • The span and zero controls are for use when checking calibration.
    They are not intended for re-ranging to a significantly different span.
  • Versatile circuit design enables operation in 2-wire current loops.

Specifications:

Service: Air and non-combustible, compatible gases.
Wetted Materials: Consult factory.
Accuracy: ±0.25% F.S.
at 70°F.
Stability: ±1% F.S./yr.
Temperature Limits: 20 to 120°F (-6.67 to 48.9°C).
Pressure Limits: 11 psig.
Thermal Effect: ±0.02% F.S./°F (0.0012% F.S./°C).
Power Requirements: 10-35 VDC (2-wire).
Output Signal: 4 to 20 mA.
Zero and Span Adjustments: Potentiometers for zero and span.
Loop Resistance: DC: 0-1250 ohms maximum.
Current Consumption: DC: 38 mA maximum.
Electrical Connections: Screw-type terminal block.
Process Connections: 1/8" female NPT.
Accessories included are two barbed fittings for 1/8" (3.12 mm) and 3/16" (4.77 mm) I.D.
rubber or vinyl tubing.
Mounting Orientation: Vertical, on a 1.378" (35 mm) DIN rail.
Weight: 4.8 oz (136 g).

Dwyer 616D-4 Specifications

Service Air and non-combustible, compatible gases
Accuracy ±0.25 FS at 77°F (25°C)
Thermal Effect ±0.02% FS/°F (0.036% FS/°C)
Stability ±1% FS/yr
Temperature Limits 14 to 185°F (-10 to 85°C)
Power Requirements 10 to 35 VDC (2-wire)
17 to 36 VDC, or isolated 21.6 to 33 VAC (3-wire)
Output Signal 4 to 20 mA (2-wire); 0 to 10 VDC (3-wire)
Zero and Span Adjustments Push buttons
Loop Resistance Current output: 0 to 1250 Ω max
Voltage output: Load resistance 1 kΩ min
Current Consumption 40 mA max
Electrical Connections Screw-type terminal block
Process Connections ⅛" female NPT
Mounting Orientation Vertical, on a 1.378" (35 mm) DIN rail
Weight 4.8 oz (136 g)
Agency Approvals CE
Click here for complete specifications on the Dwyer 616D-4

What's included with the Dwyer 616D-4

  • Dwyer 616D-4 Differential Pressure Transmitter (0-20"w.c.)

Ask a question about Dwyer 616D-4 Differential Pressure Transmitter (0-20"w.c.)

Customer Reviews for the Dwyer 616D-4

Dwyer 616D-4 PRESSURE TRANSMITTER, DIN RAIL, 0/20

  • Mounting style allows for several units to be mounted closely together reducing required space.
  • A wide range of models are available factory calibrated to specific ranges.
  • The span and zero controls are for use when checking calibration.
    They are not intended for re-ranging to a significantly different span.
  • Versatile circuit design enables operation in 2-wire current loops.

Specifications:

Service: Air and non-combustible, compatible gases.
Wetted Materials: Consult factory.
Accuracy: ±0.25% F.S.
at 70°F.
Stability: ±1% F.S./yr.
Temperature Limits: 20 to 120°F (-6.67 to 48.9°C).
Pressure Limits: 11 psig.
Thermal Effect: ±0.02% F.S./°F (0.0012% F.S./°C).
Power Requirements: 10-35 VDC (2-wire).
Output Signal: 4 to 20 mA.
Zero and Span Adjustments: Potentiometers for zero and span.
Loop Resistance: DC: 0-1250 ohms maximum.
Current Consumption: DC: 38 mA maximum.
Electrical Connections: Screw-type terminal block.
Process Connections: 1/8" female NPT.
Accessories included are two barbed fittings for 1/8" (3.12 mm) and 3/16" (4.77 mm) I.D.
rubber or vinyl tubing.
Mounting Orientation: Vertical, on a 1.378" (35 mm) DIN rail.
Weight: 4.8 oz (136 g).

Dwyer 616D-4 Specifications

Service Air and non-combustible, compatible gases
Accuracy ±0.25 FS at 77°F (25°C)
Thermal Effect ±0.02% FS/°F (0.036% FS/°C)
Stability ±1% FS/yr
Temperature Limits 14 to 185°F (-10 to 85°C)
Power Requirements 10 to 35 VDC (2-wire)
17 to 36 VDC, or isolated 21.6 to 33 VAC (3-wire)
Output Signal 4 to 20 mA (2-wire); 0 to 10 VDC (3-wire)
Zero and Span Adjustments Push buttons
Loop Resistance Current output: 0 to 1250 Ω max
Voltage output: Load resistance 1 kΩ min
Current Consumption 40 mA max
Electrical Connections Screw-type terminal block
Process Connections ⅛" female NPT
Mounting Orientation Vertical, on a 1.378" (35 mm) DIN rail
Weight 4.8 oz (136 g)
Agency Approvals CE