Dwyer 607-4 Differential Pressure Transmitter (0-2.0"w.c.),

Model: 607-4

Dwyer 607-4 Differential Pressure Transmitter (0-2.0"w.c.),

Model: 607-4

Combines very low ranges with exceptional stability, reliability and either ±0.25% or ±0.5% accuracy for the most demanding applications. Ranges from 0-0.1" to 0-25" w.c.

Combines very low ranges with exceptional stability, reliability and either ±0.25% or ±0.5% accuracy for the most demanding applications. Ranges from 0-0.1" to 0-25" w.c.

Sale Price $861.14 USD
Regular Price $921.00 USD
Availability 8 to 9 Weeks
Quantity

Traceable In-House Calibration Certificate for your 607-4 Differential Pressure Transmitter (0-2.0"w.c.)

Traceable In-House Calibration Certificate for your 607-4 Differential Pressure Transmitter (0-2.0"w.c.)

Dwyer 607-4 PRESSURE TRANSMITTER, LOW RANGE, 0-2.0, C/W NIST CERT

  • Ultra thin glass clad silicon diaphragm design resists shock and vibration, practically eliminates drift.
  • Certification to NIST standards is included with each unit.
  • Tough stainless steel housing is NEMA 2 rated to protect against moisture and dirt.
  • Use with air and other compatible gases.

Specifications:

Service: Air and nonconductive, noncorrosive gases.
Accuracy: ±0.5% or ±0.25% F.S.
Stability: ±0.5% F.S.O./yr.
Temperature Limits: -20 to 160°F (-29 to 71°C), 10 to 95% RH.
Pressure Limits: 10 psig (0.69 bar).
Compensated Temperature Range: 35 to 135°F (2 to 57°C).
Thermal Effects: ±0.015% F.S./°F (zero and span).
Power Requirements: 12-36 VDC.
Output Signal: 4 to 20 mA DC, 2-wire.
Zero and Span Adjustments: Externally accessible potentiometers, non-interactive, ±10% F.S.
adjustment.
Response Time: 250 msec max.
Loop Resistance: 0 to 1045 ohms Vmin=12V+[(.22A)(RL)].
Current Consumption: 3.6 mA (min).
Electrical Connections: Screw terminals.
Process Connections: Barbed stainless steel for 3/16" I.D. tubing.
Housing: 300 Series stainless steel (NEMA 2).
Weight: 1.04 lb (472 g).
Agency Approvals: CE.

Dwyer 607-4 Specifications

Service Air and non-conductive, non-corrosive gases
Accuracy ±0.5% or ±0.25% FS
Stability ±0.5% FS/yr
Temperature Limits -20 to 160°F (-29 to 71°C), 10 to 95% RH
Pressure Limits 10 psig (0.69 bar)
Compensated Temperature Range 35 to 135°F (2 to 57°C)
Thermal Effects ±0.015% F.S./°F (zero and span)
Power Requirements 12 to 36 VDC
Output Signal 4 to 20 mA DC, 2-wire
Zero and Span Adjustments Externally accessible potentiometers, non-interactive, ±10% F.S. adjustment
Response Time 250 ms max
Loop Resistance 0 to 1045 ohms Vmin = 12 V+ [(0.22A)(RL)]
Current Consumption 3.6 mA (min)
Electrical Connections Screw terminals
Process Connections Barbed stainless steel for 3/16" I.D. tubing
Housing 300 Series stainless steel (NEMA 2)
Weight 1.04 lb (472 g)
Agency Approvals CE
Click here for complete specifications on the Dwyer 607-4

What's included with the Dwyer 607-4

  • Dwyer 607-4 Differential Pressure Transmitter (0-2.0"w.c.),

Ask a question about Dwyer 607-4 Differential Pressure Transmitter (0-2.0"w.c.),

Customer Reviews for the Dwyer 607-4

Dwyer 607-4 PRESSURE TRANSMITTER, LOW RANGE, 0-2.0, C/W NIST CERT

  • Ultra thin glass clad silicon diaphragm design resists shock and vibration, practically eliminates drift.
  • Certification to NIST standards is included with each unit.
  • Tough stainless steel housing is NEMA 2 rated to protect against moisture and dirt.
  • Use with air and other compatible gases.

Specifications:

Service: Air and nonconductive, noncorrosive gases.
Accuracy: ±0.5% or ±0.25% F.S.
Stability: ±0.5% F.S.O./yr.
Temperature Limits: -20 to 160°F (-29 to 71°C), 10 to 95% RH.
Pressure Limits: 10 psig (0.69 bar).
Compensated Temperature Range: 35 to 135°F (2 to 57°C).
Thermal Effects: ±0.015% F.S./°F (zero and span).
Power Requirements: 12-36 VDC.
Output Signal: 4 to 20 mA DC, 2-wire.
Zero and Span Adjustments: Externally accessible potentiometers, non-interactive, ±10% F.S.
adjustment.
Response Time: 250 msec max.
Loop Resistance: 0 to 1045 ohms Vmin=12V+[(.22A)(RL)].
Current Consumption: 3.6 mA (min).
Electrical Connections: Screw terminals.
Process Connections: Barbed stainless steel for 3/16" I.D. tubing.
Housing: 300 Series stainless steel (NEMA 2).
Weight: 1.04 lb (472 g).
Agency Approvals: CE.

Dwyer 607-4 Specifications

Service Air and non-conductive, non-corrosive gases
Accuracy ±0.5% or ±0.25% FS
Stability ±0.5% FS/yr
Temperature Limits -20 to 160°F (-29 to 71°C), 10 to 95% RH
Pressure Limits 10 psig (0.69 bar)
Compensated Temperature Range 35 to 135°F (2 to 57°C)
Thermal Effects ±0.015% F.S./°F (zero and span)
Power Requirements 12 to 36 VDC
Output Signal 4 to 20 mA DC, 2-wire
Zero and Span Adjustments Externally accessible potentiometers, non-interactive, ±10% F.S. adjustment
Response Time 250 ms max
Loop Resistance 0 to 1045 ohms Vmin = 12 V+ [(0.22A)(RL)]
Current Consumption 3.6 mA (min)
Electrical Connections Screw terminals
Process Connections Barbed stainless steel for 3/16" I.D. tubing
Housing 300 Series stainless steel (NEMA 2)
Weight 1.04 lb (472 g)
Agency Approvals CE
Click here for complete specifications on the Dwyer 607-4

What's included with the Dwyer 607-4

  • Dwyer 607-4 Differential Pressure Transmitter (0-2.0"w.c.),

Ask a question about Dwyer 607-4 Differential Pressure Transmitter (0-2.0"w.c.),

Customer Reviews for the Dwyer 607-4

More Dwyer Products

Calibration Lab