The HDPQ Xplorer 400 SP is a power quality, demand and energy analyzer with 400Hz monitoring capabilities, in addition to traditional 50/60Hz measurements. Housed in a hardened IP65 enclosure without an LCD display, it is ideal for outdoor and harsh environments and it can also be powered by the circuit being measured.
The HDPQ Xplorer 400 SP is a power quality, demand and energy analyzer with 400Hz monitoring capabilities, in addition to traditional 50/60Hz measurements. Housed in a hardened IP65 enclosure without an LCD display, it is ideal for outdoor and harsh environments and it can also be powered by the circuit being measured.
The HDPQ® Xplorer SP 400 is designed for commercial, military, aviation and naval industries requiring 400Hz capabilities that are not available in most power quality and energy analyzers. Designed with 400Hz applications in mind, it is also an all-purpose tool that can be used for any traditional 50/60Hz application.
Features
Applications
Measured Parameters | |
Differential Voltage Inputs (4) | 1 to 1000Vrms, AC/DC; ±0.1% rdg., <40V ±0.05% FS; 512 samples/cycle; 16-bit ADC resolution |
Current Inputs with CTs (4) | 0.1 to 6000Arms AC; ±0.1% rdg. ±0.05% FS; 512 samples/cycle; 16-bit ADC resolution |
Frequency Range | 42.5 to 69Hz, ±0.01Hz, 380 to 420Hz ±0.1Hz |
Calculated Parameters | |
Vthd | 0 to 100%, ±5% for V ≥ 1% Vnom |
V Ind Harm | DC, 2 to 127, ±5% for V ≥ 1% Vnom |
Ithd | 0 to 100%, ±5% for V ≥ 1% Vnom |
I Ind Harm | DC, 2 to 63, ±5% for V ≥ 1% Vnom |
Pst | 10 minutes: 0.2 to 10, ±0.05 at Pst=1 |
Plt | 2 hours: 0.2 to 10, ±0.05 at Pst=1 |
General Specifications | |
Memory Size | 4GB |
Power Supply | 90 to 600VAC/500VDC (50/60Hz); powered by the phase being measured or other source |
Dimensions | 11 x 2.5 x 6.5in (27.9 x 6.4 x 16.5cm) |
Weight | 3.2lbs (1.45kg) |
Measured Parameters | |
Differential Voltage Inputs (4) | 1 to 1000Vrms, AC/DC; ±0.1% rdg., <40V ±0.05% FS; 512 samples/cycle; 16-bit ADC resolution |
Current Inputs with CTs (4) | 0.1 to 6000Arms AC; ±0.1% rdg. ±0.05% FS; 512 samples/cycle; 16-bit ADC resolution |
Frequency Range | 42.5 to 69Hz, ±0.01Hz, 380 to 420Hz ±0.1Hz |
Calculated Parameters | |
Vthd | 0 to 100%, ±5% for V ≥ 1% Vnom |
V Ind Harm | DC, 2 to 127, ±5% for V ≥ 1% Vnom |
Ithd | 0 to 100%, ±5% for V ≥ 1% Vnom |
I Ind Harm | DC, 2 to 63, ±5% for V ≥ 1% Vnom |
Pst | 10 minutes: 0.2 to 10, ±0.05 at Pst=1 |
Plt | 2 hours: 0.2 to 10, ±0.05 at Pst=1 |
General Specifications | |
Memory Size | 4GB |
Power Supply | 90 to 600VAC/500VDC (50/60Hz); powered by the phase being measured or other source |
Dimensions | 11 x 2.5 x 6.5in (27.9 x 6.4 x 16.5cm) |
Weight | 3.2lbs (1.45kg) |