Dent ElitePro EXC-I-N-C Energy Data Logger, Int'l, USB/Ethernet

Model: EXC-I-N-C

Dent ElitePro EXC-I-N-C Energy Data Logger, Int'l, USB/Ethernet

Model: EXC-I-N-C

International recording power meter with USB/Ethernet communications, includes crocdile clips. Capture kWh/kW energy and demand data as well as virtually all relevant energy parameters for diagnostics and monitoring on three-phase or single-phase circuit installations. Please note that all DENT software is compatible with Windows 7 and newer operating systems. It is not compatible with macOS. Includes soft carrying case.

International recording power meter with USB/Ethernet communications, includes crocdile clips. Capture kWh/kW energy and demand data as well as virtually all relevant energy parameters for diagnostics and monitoring on three-phase or single-phase circuit installations. Please note that all DENT software is compatible with Windows 7 and newer operating systems. It is not compatible with macOS. Includes soft carrying case.

Sale Price $1738.40 USD
Regular Price $2133.00 USD
Availability 1 to 2 Weeks
Quantity

Dent EXC-I-N-C ELITEpro XC Energy Datalogger with Croc Clips & Case

The Dent ELITEpro XC Energy Datalogger is ideal for the measurement and analysis of energy consumption data, gathered from analog voltage and current inputs. This model includes a set of crocodile clips and a case, and is designed for international use. The ELITEpro XC features configurable analog inputs with a voltage transducer range of 0 to 10VDC and a current loop transducer range of 0 or 4 to 20mA. This datalogger may be used on single or three-phase systems, using phase-to-phase services of a range of 80 to 600V (AC or DC) when line powered and 0 to 600V (AC or DC) when externally powered.

The ELITEpro XC is easy to use, with a simple setup and DENT's patended PhaseChek indicator to ensure proper instillation. This datalogger communicated quickly via USB connection and features a standard Ethernet port. Its compact, durable design means the ELITEpro XC can fit easily inside of breaker panels-making it the ideal datalogger for energy audits, surveys, and load profiling.

Step-by-Step: Connect to a Remote ELITEpro XC Using Port Forwarding

If your ELITEpro XC is on a local area network at a remote project site, but you're hundreds of miles away, at your office, and need to download data off the meter? Port Forwarding makes it possible to complete the download.

What Happens to the ELITEpro XC During a Power Outage

Learn how to use a handy ELOG feature, called Fill Missing Records, to help correct data downloaded from a logger that has experienced a power outage.

Technical Specifications:

  • Service Type: Single Phase (two wire or three wire), Three Phase-Four Wire (WYE), Three Phase-Three Wire (Delta), DC Systems (Solar/Battery)
  • Voltage Channels: 3 channels, CAT III, 0-600 VAC (line-to-line) or 600 VDC
  • Current Channels: 4 channels, .67 VAC max, +/- 1 VDC. Ideal for 333 mV full scale CTs
  • Maximum Current Input: External transducer dependent. 200% of current transducer rating (mV CTs). Measure up to 6000A with RoCoil CTs.
  • Measurement Type: True RMS using high-speed digital signal processing (DSP)
  • Line Frequency: DC/50/60 Hz*
  • Waveform Sampling: 12 kHz
  • Channel Sampling Rate: .125 seconds
  • Integration Period: 1, 3, 15, 30 seconds; 1, 2, 5, 10, 15, 20, and 30 minutes; 1 and 12 hours, 1 day
  • Energy Measurements: Volts, Amps, Amp-Hrs (Ah), kW, kWh, kVAR, kVARh, kVA, kVAh, Displacement Power Factor (dPF). All parameters for each phase and for system total.
  • Analog Measurements: 0-10 Volts, 0-20 or 4-20 mA current loop. Non-isolated, external power for current loop. User scaling for sensor reporting in physical units.
  • Accuracy: Better than 1% (<0.2% typical) for V, A, kW, kVAR, kVA, PF, Analog
  • Resolution: 0.01 Amp, 0.1 Volt, 1 Watt, 1 VAR, 1 VA, 0.01 PF, 0.01 ANA
  • Led Indicators: Tri-color (red, green, blue), 1 LED indicates communication (blue for wireless, Bluetooth or Ethernet), 4 LEDs for correct phasing (PhaseChek).

Power Specifications:

  • Line-Power: From L1 Phase to L2 Phase. 80-600V (AC or DC) CAT III DC/50/60 Hz, 125 mA, 5 W, or 10 VA max. Non-user replaceable .5 Amp internal fuse protection.
  • Power In: 6-10 VDC, 500 mA
  • Power Out: 6 VDC, 200 mA max

Communications Specifications:

  • USB (Standard): USB standard (Type B). 1.8 M (6 ft) A-to-B USB Cable (included)
  • Ethernet (Standard): Standard RJ-45 Connector supports 10/100 MB Ethernet over Cat 5 or better. Configure for DHCP or Static IP.
  • Bluetooth Wireless Technology (Optional): Internal antenna with 10-100 ft range (typical). Requires Bluetooth wireless technology adapter on Windows PC. Adapter must support the Serial Port Profile (SPP).
  • Wi-Fi Adapter (Optional): Wi-Fi option available as two separate configurations: Internal antenna: typical range 75-300 ft. or External 3 dbi antenna: typical range 150-300 ft.

Mechanical Specifications:

  • Operating Temperature: -7 to + 60°C (20 to 140°F)
  • Operating Humidity: 5% to 95% non-condensing
  • Enclosure Type: ABS plastic, 94-V0 flammability rating
  • Weight: 340 g (12 ounces)
  • Dimensions: 21.6 x 6.3 x 4.7 cm (8.5" x 2.5" x 1.9")

Dent EXC-I-N-C Specifications

Technical
Service Type Single phase (two wire or three wire), three phase-four wire (WYE), three phase-three wire (Delta), DC systems (solar/battery)
Voltage Channels 3 channels, CAT III, 0 to 600 VAC (line-to-line) or 600 VDC
Current Channels 4 channels, 0.67 VAC max, +/- 1 VDC
Ideal for 333 mV full scale CTs
Maximum Current Input External transducer dependent
200% of current transducer rating (mV CTs)
Measure up to 6000 A with RoCoil CTs.
Measurement Type True RMS using high-speed digital signal processing (DSP)
Line Frequency DC/50/60/400 Hz*
Waveform Sampling 12 kHz
Channel Sampling Rate 0.125 seconds
Integration Period 1, 3, 15, 30 seconds; 1, 2, 5, 10, 15, 20, and 30 minutes; 1 and 12 hours, 1 day
Energy Measurements Volts, Amps, Amp-Hrs (Ah), kW, kWh, kVAR, kVARh, kVA, kVAh, Displacement Power Factor (dPF). All parameters for each phase and for system total
Analog Measurements 0 to 10 V, 0 or 4 to 20 mA current loop
Non-isolated, external power for current loop. User scaling for sensor reporting in physical units
Accuracy Better than 1% (<0.2% typical) for V, A, kW, kVAR, kVA, PF, Analog
Resolution 0.01 A, 0.1 V, 1 W, 1 VAR, 1 VA, 0.01 PF, 0.01 ANA
LED Indicators Tri-color (red, green, blue): 1 LED indicates communication (blue for wireless, Bluetooth® or Ethernet), 4 LEDs for correct phasing (PhaseChek™).
Power
Line-Power From L1 Phase to L2 Phase. 80 to 600 V (AC or DC) CAT III DC/50/60/400 Hz, 125 mA, 5 W, or 10 VA max
Non-user replaceable 0.5 A internal fuse protection.
Power In 6 to 10 VDC, 500 mA
Power Out 6 VDC, 200 mA max
Communications
USB (Standard) USB standard (type B)
6' (1.8 m) A-to-B USB cable (included)
Ethernet (Standard) Standard RJ-45 connector supports 10/100 MB Ethernet over Cat 5 or better
Configure for DHCP or static IP
Bluetooth Wireless Technology (Optional) Internal antenna with 10 to 100' range (typical)
Requires Bluetooth® wireless technology adapter on Windows PC
Adapter must support the Serial Port Profile (SPP).
Wi-Fi Adapter† (optional) Wi-Fi option available as two separate configurations:
  • Internal antenna: typical range 75 to 300'
  • External 3 dbi antenna: typical range 150 to 300'
Mechanical
Operating Temperature 20 to 140 °F (-7 to 60 °C)
Operating Humidity 5 to 95% non-condensing
Enclosure Type ABS plastic, 94-V0 flammability rating
Weight 12 ounces (340 g)
Dimensions 8.5 x 2.5 x 1.9" (21.6 x 6.3 x 4.7 cm)

* Performance varies at 400 Hz operation. Contact the factory for details.
† ELITEpro XC loggers that are equipped with a Wi-Fi package contain an internal antenna. An external antenna is optional. You may toggle between using the internal and external antenna (if it is available on your logger) by checking or unchecking the Use External Antenna checkbox in ELOG.
US/NORTH AMERICAN ELITEpro XC configuration includes 4 color (black, blue, red, white) voltage leads and croc clips. INTERNATIONAL ELITEpro XC configuration includes 3 black voltage lead connections, 1 white connection (neutral) and 5 color (black, blue, red, white, yellow) voltage leads and croc clips.

Click here for complete specifications on the Dent EXC-I-N-C

Connect to a remote ELITEpro XC using Port Forwarding

What happens if your ELITEpro XC is on a local area network at a remote project site, but you're hundreds of miles away, at your office, and need to download data off the meter? Port Forwarding makes it possible to complete the download and, with a little planning, you probably already have everything you need to successfully download your data.

Port forwarding is a name given to the combined technique of:

  1. Translating the address and/or port number of a packet to a new destination
  2. Possibly accepting such packets in a packet filter (firewall)
  3. Forwarding the packet according to the routing table

Port forwarding allows remote computers (for example, computers on the Internet) to connect to a specific computer or service within a private local area network (LAN). In the case of the ELITEpro XC (or ELITEpro SP) with Ethernet, port forwarding allows remote connection between the ELITEpro XC and a computer on another network through the firewall via ELOG software.

For instance, if the ELITEpro XC is on the local area network at a remote project site, but you wish to download data off the meter from the office, you can remotely access the ELITEpro XC from any computer with an Internet connection through ELOG.

Requirements

Prior to beginning, confirm the following information:

  • Know the external IP address of the router on the network with the ELITEpro XC. This address is usually assigned by the ISP and is typically static. However, it may be dynamic, changing the address every other day. This can be easily found by someone inside the network by visiting www.whatsmyip.com
  • Confirm that your router can be configured for port forwarding. Verify this with your router's documentation or by visiting the manufacturer's website
  • Know the ELITEpro XC meter's IP address

Note: The ELITEpro XC itself does not need to be configured for Port Forwarding. All the configuration takes place on the router.

Each router manufacturer uses slightly different software. Check your router's documentation for specific directions on how to port forward with your router's software. Regardless of what software is on your router, you'll be required to enter the same general information.

  1. A text field where you can type the name of the application or service (in this case, it's helpful to reference the "ELITEpro XC" or the EXC's serial number)
  2. Incoming port the router should watch for
  3. The protocol to watch for: TCP or UDP. Choose "both" if you're unsure
  4. The IP address that is the destination for this port's request (i.e., the EXC's IP address)
  5. Which port the request should be targeted to on the destination IP. The default is 3001

Instructions

Here are the steps to connecting your networked ELITEpro XC from a different network:

  1. Obtain an internal IP address that is routable to an external IP address. If you are unsure of which IP address to use, check with your IT department
  2. The external IP address gets forwarded to the internal IP address. For instance, the external IP address 212.45.67.89 may be forwarded to internal IP address 192.168.1.50.
  3. Determine which port should e used to connect to the ELITEpro XC. The default port is 3001. Check with your IT department if you are unsure
  4. Using ELOG on the remote PC, go through the menu: Logger > Communication > Network Connect
  5. Enter the external IP address for the network you wish to connect to in the Network IP address box
  6. Enter the Port Number for the logger you wish to connect to
  7. Click OK
  8. You should now be connected to the remote ELITEpro XC
elitepro port forwarding

What's included with the Dent EXC-I-N-C

  • Dent ElitePro EXC-I-N-C Energy Data Logger, Int'l, USB/Ethernet

Click on a category to view a selection of compatible accessories with the Dent ElitePro EXC-I-N-C Energy Data Logger, Int'l, USB/Ethernet.

Dent LD SKTSPYEL Replacement Unterminated Voltage Lead for the ElitePro Series, Yellow, 10" LD SKTSPYEL
Featuring an unterminated yellow voltage lead that connects to the 2M voltage leads on the ElitePro Power Meters to provide an unterminated, tinned end for hard-wiring to the electrical panel. For use in place of croc or shark clips.




Dent LD SKTSPWHT Replacement Unterminated Voltage Lead for the ElitePro Series, White, 10" LD SKTSPWHT
Featuring an unterminated white voltage lead that connects to the 2M voltage leads on the ElitePro Power Meters to provide an unterminated, tinned end for hard-wiring to the electrical panel. For use in place of croc or shark clips.




Dent LD SKTSPRED Replacement Unterminated Voltage Lead for the ElitePro Series, Red, 10" LD SKTSPRED
Featuring an unterminated red voltage lead that connects to the 2M voltage leads on the ElitePro Power Meters to provide an unterminated, tinned end for hard-wiring to the electrical panel. For use in place of croc or shark clips.




Dent LD SKTSPBLU Replacement Unterminated Voltage Lead for the ElitePro Series, Blue, 10" LD SKTSPBLU
Featuring an unterminated blue voltage lead that connects to the 2M voltage leads on the ElitePro Power Meters to provide an unterminated, tinned end for hard-wiring to the electrical panel. For use in place of croc or shark clips.




Dent LD SKTSPBLK Replacement Unterminated Voltage Lead for the ElitePro Series, Black, 10" LD SKTSPBLK
Featuring an unterminated black voltage lead that connects to the 2M voltage leads on the ElitePro Power Meters to provide an unterminated, tinned end for hard-wiring to the electrical panel. For use in place of croc or shark clips.




Dent LD 2M ESP YEL Replacement Voltage Lead for the ElitePro XC or ElitePro SP, Yellow, 2 m LD 2M ESP YEL
Featuring an individual, 2-meter yellow voltage lead for the ElitePro XC or ElitePro SP Power Meters. It is UL rated, 1000V, CATIII.




Dent LD 2M ESP WHT Replacement Voltage Lead for the ElitePro XC or ElitePro SP, White, 2 m LD 2M ESP WHT
Featuring an individual, 2-meter white voltage lead for the ElitePro XC or ElitePro SP Power Meters. It is UL rated, 1000V, CATIII.




Dent LD 2M ESP RED Replacement Voltage Lead for the ElitePro XC or ElitePro SP, Red, 2 m LD 2M ESP RED
Featuring an individual, 2-meter red voltage lead for the ElitePro XC or ElitePro SP Power Meters. It is UL rated, 1000V, CATIII.




Dent LD 2M ESP BLU Replacement Voltage Lead for the ElitePro XC or ElitePro SP, Blue, 2 m LD 2M ESP BLU
Featuring an individual, 2-meter blue voltage lead for the ElitePro XC or ElitePro SP Power Meters. It is UL rated, 1000V, CATIII.




Dent LD 2M ESP BLK Replacement Voltage Lead for the ElitePro XC or ElitePro SP, Black, 2 m LD 2M ESP BLK
Featuring an individual, 2-meter black voltage lead for the ElitePro XC or ElitePro SP Power Meters. It is UL rated, 1000V, CATIII.




Dent CT-HSC-020-U Mini Hinged Current Transformer, 20A CT-HSC-020-U
Features a high accuracy over a wide range with a superior phase shift that is ideal for areas where space is limited such as when metering multiples loads within an electrical panel. Offers a 20A amp rating.




Dent CT-HSC-050-U Mini Hinged Current Transformer, 50A CT-HSC-050-U
Features a high accuracy over a wide range with a superior phase shift that is ideal for areas where space is limited such as when metering multiples loads within an electrical panel. Offers a 50A amp rating.




Dent CT-HMC-0100-U Midi Hinged Current Transformer, 100A CT-HMC-0100-U
Features a high accuracy over a wide range with a superior phase shift that is ideal for areas where space is limited such as when metering multiples loads within an electrical panel. Offers a 100A amp rating.




Dent CT-HMC-0200-U Midi Hinged Current Transformer, 200A CT-HMC-0200-U
Features a high accuracy over a wide range with a superior phase shift that is ideal for areas where space is limited such as when metering multiples loads within an electrical panel. Offers a 200A amp rating.




Dent CONN 8POS PLUG 3.81MM eight position connector for exc analog input channels CONN 8POS PLUG 3.81MM
Eight position connector for EXC analog input channels.




Dent EXC-UG-WI wifi with internal antenna module upgrade for ElitePro XC EXC-UG-WI
Wifi with internal antenna module upgrade for ElitePro XC. Please note that all DENT software is compatible with Windows 7 and newer operating systems. It is not compatible with macOS.




Dent CT-R47-A4-U RoCoil Flexible Current Transformer, 47" CT-R47-A4-U
Designed for accurate non-intrusive measurement of AC current, pulsed DC or distorted waveforms where conventional rigid core CTs are unsuitable. This type of sensor may be used to measure AC current over a wide dynamic range and from 20 Hz to 5 kHz. It features a length of 47".




Dent CT-R36-A4-U RoCoil Flexible Current Transformer, 35" CT-R36-A4-U
Designed for accurate non-intrusive measurement of AC current, pulsed DC or distorted waveforms where conventional rigid core CTs are unsuitable. This type of sensor may be used to measure AC current over a wide dynamic range and from 20 Hz to 5 kHz. It features a length of 35".




Dent CT-R24-A4-U RoCoil Flexible Current Transformer, 24" CT-R24-A4U
Designed for accurate non-intrusive measurement of AC current, pulsed DC or distorted waveforms where conventional rigid core CTs are unsuitable. This type of sensor may be used to measure AC current over a wide dynamic range and from 20 Hz to 5 kHz. It features a length of 24".




Dent CT-R16-A4-U RoCoil Flexible Current Transformer, 16" CT-R16-A4U
Designed for accurate non-intrusive measurement of AC current, pulsed DC or distorted waveforms where conventional rigid core CTs are unsuitable. This type of sensor may be used to measure AC current over a wide dynamic range and from 20 Hz to 5 kHz. It features a length of 16".




Dent CT-CON-0150EZ-U Current Transformer CT-CON-0150EZ-U
Clamp-On Current Transformer. 1" (25Mm) Round Opening.




Dent CT-SCM-0400-U Medium Split Core Current Transformer, 400A CT-SCM-0400-U
Provides a linear output voltage that is proportional to the input current that is safe and easy to install over existing electrical power lines without disconnection or interruption. Features a window size of 1.25" and offers a 400A amp rating.




Dent CT-SCM-0600-U Medium Split Core Current Transformer, 600A CT-SCM-0600-U
Provides a linear output voltage that is proportional to the input current that is safe and easy to install over existing electrical power lines without disconnection or interruption. Features a window size of 1.25" and offers a 600A amp rating.




Dent CT-SCL-1000-U Large Split Core Current Transformer, 1000A CT-SCL-1000-U
Provides a linear output voltage that is proportional to the input current that is safe and easy to install over existing electrical power lines without disconnection or interruption. Features a window size of 2.0" and offers a 1000A amp rating.
















































Ask a question about Dent ElitePro EXC-I-N-C Energy Data Logger, Int'l, USB/Ethernet

Customer Reviews for the Dent EXC-I-N-C

Dent EXC-I-N-C ELITEpro XC Energy Datalogger with Croc Clips & Case

The Dent ELITEpro XC Energy Datalogger is ideal for the measurement and analysis of energy consumption data, gathered from analog voltage and current inputs. This model includes a set of crocodile clips and a case, and is designed for international use. The ELITEpro XC features configurable analog inputs with a voltage transducer range of 0 to 10VDC and a current loop transducer range of 0 or 4 to 20mA. This datalogger may be used on single or three-phase systems, using phase-to-phase services of a range of 80 to 600V (AC or DC) when line powered and 0 to 600V (AC or DC) when externally powered.

The ELITEpro XC is easy to use, with a simple setup and DENT's patended PhaseChek indicator to ensure proper instillation. This datalogger communicated quickly via USB connection and features a standard Ethernet port. Its compact, durable design means the ELITEpro XC can fit easily inside of breaker panels-making it the ideal datalogger for energy audits, surveys, and load profiling.

Step-by-Step: Connect to a Remote ELITEpro XC Using Port Forwarding

If your ELITEpro XC is on a local area network at a remote project site, but you're hundreds of miles away, at your office, and need to download data off the meter? Port Forwarding makes it possible to complete the download.

What Happens to the ELITEpro XC During a Power Outage

Learn how to use a handy ELOG feature, called Fill Missing Records, to help correct data downloaded from a logger that has experienced a power outage.

Technical Specifications:

  • Service Type: Single Phase (two wire or three wire), Three Phase-Four Wire (WYE), Three Phase-Three Wire (Delta), DC Systems (Solar/Battery)
  • Voltage Channels: 3 channels, CAT III, 0-600 VAC (line-to-line) or 600 VDC
  • Current Channels: 4 channels, .67 VAC max, +/- 1 VDC. Ideal for 333 mV full scale CTs
  • Maximum Current Input: External transducer dependent. 200% of current transducer rating (mV CTs). Measure up to 6000A with RoCoil CTs.
  • Measurement Type: True RMS using high-speed digital signal processing (DSP)
  • Line Frequency: DC/50/60 Hz*
  • Waveform Sampling: 12 kHz
  • Channel Sampling Rate: .125 seconds
  • Integration Period: 1, 3, 15, 30 seconds; 1, 2, 5, 10, 15, 20, and 30 minutes; 1 and 12 hours, 1 day
  • Energy Measurements: Volts, Amps, Amp-Hrs (Ah), kW, kWh, kVAR, kVARh, kVA, kVAh, Displacement Power Factor (dPF). All parameters for each phase and for system total.
  • Analog Measurements: 0-10 Volts, 0-20 or 4-20 mA current loop. Non-isolated, external power for current loop. User scaling for sensor reporting in physical units.
  • Accuracy: Better than 1% (<0.2% typical) for V, A, kW, kVAR, kVA, PF, Analog
  • Resolution: 0.01 Amp, 0.1 Volt, 1 Watt, 1 VAR, 1 VA, 0.01 PF, 0.01 ANA
  • Led Indicators: Tri-color (red, green, blue), 1 LED indicates communication (blue for wireless, Bluetooth or Ethernet), 4 LEDs for correct phasing (PhaseChek).

Power Specifications:

  • Line-Power: From L1 Phase to L2 Phase. 80-600V (AC or DC) CAT III DC/50/60 Hz, 125 mA, 5 W, or 10 VA max. Non-user replaceable .5 Amp internal fuse protection.
  • Power In: 6-10 VDC, 500 mA
  • Power Out: 6 VDC, 200 mA max

Communications Specifications:

  • USB (Standard): USB standard (Type B). 1.8 M (6 ft) A-to-B USB Cable (included)
  • Ethernet (Standard): Standard RJ-45 Connector supports 10/100 MB Ethernet over Cat 5 or better. Configure for DHCP or Static IP.
  • Bluetooth Wireless Technology (Optional): Internal antenna with 10-100 ft range (typical). Requires Bluetooth wireless technology adapter on Windows PC. Adapter must support the Serial Port Profile (SPP).
  • Wi-Fi Adapter (Optional): Wi-Fi option available as two separate configurations: Internal antenna: typical range 75-300 ft. or External 3 dbi antenna: typical range 150-300 ft.

Mechanical Specifications:

  • Operating Temperature: -7 to + 60°C (20 to 140°F)
  • Operating Humidity: 5% to 95% non-condensing
  • Enclosure Type: ABS plastic, 94-V0 flammability rating
  • Weight: 340 g (12 ounces)
  • Dimensions: 21.6 x 6.3 x 4.7 cm (8.5" x 2.5" x 1.9")

Dent EXC-I-N-C Specifications

Technical
Service Type Single phase (two wire or three wire), three phase-four wire (WYE), three phase-three wire (Delta), DC systems (solar/battery)
Voltage Channels 3 channels, CAT III, 0 to 600 VAC (line-to-line) or 600 VDC
Current Channels 4 channels, 0.67 VAC max, +/- 1 VDC
Ideal for 333 mV full scale CTs
Maximum Current Input External transducer dependent
200% of current transducer rating (mV CTs)
Measure up to 6000 A with RoCoil CTs.
Measurement Type True RMS using high-speed digital signal processing (DSP)
Line Frequency DC/50/60/400 Hz*
Waveform Sampling 12 kHz
Channel Sampling Rate 0.125 seconds
Integration Period 1, 3, 15, 30 seconds; 1, 2, 5, 10, 15, 20, and 30 minutes; 1 and 12 hours, 1 day
Energy Measurements Volts, Amps, Amp-Hrs (Ah), kW, kWh, kVAR, kVARh, kVA, kVAh, Displacement Power Factor (dPF). All parameters for each phase and for system total
Analog Measurements 0 to 10 V, 0 or 4 to 20 mA current loop
Non-isolated, external power for current loop. User scaling for sensor reporting in physical units
Accuracy Better than 1% (<0.2% typical) for V, A, kW, kVAR, kVA, PF, Analog
Resolution 0.01 A, 0.1 V, 1 W, 1 VAR, 1 VA, 0.01 PF, 0.01 ANA
LED Indicators Tri-color (red, green, blue): 1 LED indicates communication (blue for wireless, Bluetooth® or Ethernet), 4 LEDs for correct phasing (PhaseChek™).
Power
Line-Power From L1 Phase to L2 Phase. 80 to 600 V (AC or DC) CAT III DC/50/60/400 Hz, 125 mA, 5 W, or 10 VA max
Non-user replaceable 0.5 A internal fuse protection.
Power In 6 to 10 VDC, 500 mA
Power Out 6 VDC, 200 mA max
Communications
USB (Standard) USB standard (type B)
6' (1.8 m) A-to-B USB cable (included)
Ethernet (Standard) Standard RJ-45 connector supports 10/100 MB Ethernet over Cat 5 or better
Configure for DHCP or static IP
Bluetooth Wireless Technology (Optional) Internal antenna with 10 to 100' range (typical)
Requires Bluetooth® wireless technology adapter on Windows PC
Adapter must support the Serial Port Profile (SPP).
Wi-Fi Adapter† (optional) Wi-Fi option available as two separate configurations:
  • Internal antenna: typical range 75 to 300'
  • External 3 dbi antenna: typical range 150 to 300'
Mechanical
Operating Temperature 20 to 140 °F (-7 to 60 °C)
Operating Humidity 5 to 95% non-condensing
Enclosure Type ABS plastic, 94-V0 flammability rating
Weight 12 ounces (340 g)
Dimensions 8.5 x 2.5 x 1.9" (21.6 x 6.3 x 4.7 cm)

* Performance varies at 400 Hz operation. Contact the factory for details.
† ELITEpro XC loggers that are equipped with a Wi-Fi package contain an internal antenna. An external antenna is optional. You may toggle between using the internal and external antenna (if it is available on your logger) by checking or unchecking the Use External Antenna checkbox in ELOG.
US/NORTH AMERICAN ELITEpro XC configuration includes 4 color (black, blue, red, white) voltage leads and croc clips. INTERNATIONAL ELITEpro XC configuration includes 3 black voltage lead connections, 1 white connection (neutral) and 5 color (black, blue, red, white, yellow) voltage leads and croc clips.

Click here for complete specifications on the Dent EXC-I-N-C

Connect to a remote ELITEpro XC using Port Forwarding

What happens if your ELITEpro XC is on a local area network at a remote project site, but you're hundreds of miles away, at your office, and need to download data off the meter? Port Forwarding makes it possible to complete the download and, with a little planning, you probably already have everything you need to successfully download your data.

Port forwarding is a name given to the combined technique of:

  1. Translating the address and/or port number of a packet to a new destination
  2. Possibly accepting such packets in a packet filter (firewall)
  3. Forwarding the packet according to the routing table

Port forwarding allows remote computers (for example, computers on the Internet) to connect to a specific computer or service within a private local area network (LAN). In the case of the ELITEpro XC (or ELITEpro SP) with Ethernet, port forwarding allows remote connection between the ELITEpro XC and a computer on another network through the firewall via ELOG software.

For instance, if the ELITEpro XC is on the local area network at a remote project site, but you wish to download data off the meter from the office, you can remotely access the ELITEpro XC from any computer with an Internet connection through ELOG.

Requirements

Prior to beginning, confirm the following information:

  • Know the external IP address of the router on the network with the ELITEpro XC. This address is usually assigned by the ISP and is typically static. However, it may be dynamic, changing the address every other day. This can be easily found by someone inside the network by visiting www.whatsmyip.com
  • Confirm that your router can be configured for port forwarding. Verify this with your router's documentation or by visiting the manufacturer's website
  • Know the ELITEpro XC meter's IP address

Note: The ELITEpro XC itself does not need to be configured for Port Forwarding. All the configuration takes place on the router.

Each router manufacturer uses slightly different software. Check your router's documentation for specific directions on how to port forward with your router's software. Regardless of what software is on your router, you'll be required to enter the same general information.

  1. A text field where you can type the name of the application or service (in this case, it's helpful to reference the "ELITEpro XC" or the EXC's serial number)
  2. Incoming port the router should watch for
  3. The protocol to watch for: TCP or UDP. Choose "both" if you're unsure
  4. The IP address that is the destination for this port's request (i.e., the EXC's IP address)
  5. Which port the request should be targeted to on the destination IP. The default is 3001

Instructions

Here are the steps to connecting your networked ELITEpro XC from a different network:

  1. Obtain an internal IP address that is routable to an external IP address. If you are unsure of which IP address to use, check with your IT department
  2. The external IP address gets forwarded to the internal IP address. For instance, the external IP address 212.45.67.89 may be forwarded to internal IP address 192.168.1.50.
  3. Determine which port should e used to connect to the ELITEpro XC. The default port is 3001. Check with your IT department if you are unsure
  4. Using ELOG on the remote PC, go through the menu: Logger > Communication > Network Connect
  5. Enter the external IP address for the network you wish to connect to in the Network IP address box
  6. Enter the Port Number for the logger you wish to connect to
  7. Click OK
  8. You should now be connected to the remote ELITEpro XC
elitepro port forwarding

What's included with the Dent EXC-I-N-C

  • Dent ElitePro EXC-I-N-C Energy Data Logger, Int'l, USB/Ethernet

Click on a category to view a selection of compatible accessories with the Dent ElitePro EXC-I-N-C Energy Data Logger, Int'l, USB/Ethernet.

Dent LD SKTSPYEL Replacement Unterminated Voltage Lead for the ElitePro Series, Yellow, 10" LD SKTSPYEL
Featuring an unterminated yellow voltage lead that connects to the 2M voltage leads on the ElitePro Power Meters to provide an unterminated, tinned end for hard-wiring to the electrical panel. For use in place of croc or shark clips.




Dent LD SKTSPWHT Replacement Unterminated Voltage Lead for the ElitePro Series, White, 10" LD SKTSPWHT
Featuring an unterminated white voltage lead that connects to the 2M voltage leads on the ElitePro Power Meters to provide an unterminated, tinned end for hard-wiring to the electrical panel. For use in place of croc or shark clips.




Dent LD SKTSPRED Replacement Unterminated Voltage Lead for the ElitePro Series, Red, 10" LD SKTSPRED
Featuring an unterminated red voltage lead that connects to the 2M voltage leads on the ElitePro Power Meters to provide an unterminated, tinned end for hard-wiring to the electrical panel. For use in place of croc or shark clips.




Dent LD SKTSPBLU Replacement Unterminated Voltage Lead for the ElitePro Series, Blue, 10" LD SKTSPBLU
Featuring an unterminated blue voltage lead that connects to the 2M voltage leads on the ElitePro Power Meters to provide an unterminated, tinned end for hard-wiring to the electrical panel. For use in place of croc or shark clips.




Dent LD SKTSPBLK Replacement Unterminated Voltage Lead for the ElitePro Series, Black, 10" LD SKTSPBLK
Featuring an unterminated black voltage lead that connects to the 2M voltage leads on the ElitePro Power Meters to provide an unterminated, tinned end for hard-wiring to the electrical panel. For use in place of croc or shark clips.




Dent LD 2M ESP YEL Replacement Voltage Lead for the ElitePro XC or ElitePro SP, Yellow, 2 m LD 2M ESP YEL
Featuring an individual, 2-meter yellow voltage lead for the ElitePro XC or ElitePro SP Power Meters. It is UL rated, 1000V, CATIII.




Dent LD 2M ESP WHT Replacement Voltage Lead for the ElitePro XC or ElitePro SP, White, 2 m LD 2M ESP WHT
Featuring an individual, 2-meter white voltage lead for the ElitePro XC or ElitePro SP Power Meters. It is UL rated, 1000V, CATIII.




Dent LD 2M ESP RED Replacement Voltage Lead for the ElitePro XC or ElitePro SP, Red, 2 m LD 2M ESP RED
Featuring an individual, 2-meter red voltage lead for the ElitePro XC or ElitePro SP Power Meters. It is UL rated, 1000V, CATIII.




Dent LD 2M ESP BLU Replacement Voltage Lead for the ElitePro XC or ElitePro SP, Blue, 2 m LD 2M ESP BLU
Featuring an individual, 2-meter blue voltage lead for the ElitePro XC or ElitePro SP Power Meters. It is UL rated, 1000V, CATIII.




Dent LD 2M ESP BLK Replacement Voltage Lead for the ElitePro XC or ElitePro SP, Black, 2 m LD 2M ESP BLK
Featuring an individual, 2-meter black voltage lead for the ElitePro XC or ElitePro SP Power Meters. It is UL rated, 1000V, CATIII.




Dent CT-HSC-020-U Mini Hinged Current Transformer, 20A CT-HSC-020-U
Features a high accuracy over a wide range with a superior phase shift that is ideal for areas where space is limited such as when metering multiples loads within an electrical panel. Offers a 20A amp rating.




Dent CT-HSC-050-U Mini Hinged Current Transformer, 50A CT-HSC-050-U
Features a high accuracy over a wide range with a superior phase shift that is ideal for areas where space is limited such as when metering multiples loads within an electrical panel. Offers a 50A amp rating.




Dent CT-HMC-0100-U Midi Hinged Current Transformer, 100A CT-HMC-0100-U
Features a high accuracy over a wide range with a superior phase shift that is ideal for areas where space is limited such as when metering multiples loads within an electrical panel. Offers a 100A amp rating.




Dent CT-HMC-0200-U Midi Hinged Current Transformer, 200A CT-HMC-0200-U
Features a high accuracy over a wide range with a superior phase shift that is ideal for areas where space is limited such as when metering multiples loads within an electrical panel. Offers a 200A amp rating.




Dent CONN 8POS PLUG 3.81MM eight position connector for exc analog input channels CONN 8POS PLUG 3.81MM
Eight position connector for EXC analog input channels.




Dent EXC-UG-WI wifi with internal antenna module upgrade for ElitePro XC EXC-UG-WI
Wifi with internal antenna module upgrade for ElitePro XC. Please note that all DENT software is compatible with Windows 7 and newer operating systems. It is not compatible with macOS.




Dent CT-R47-A4-U RoCoil Flexible Current Transformer, 47" CT-R47-A4-U
Designed for accurate non-intrusive measurement of AC current, pulsed DC or distorted waveforms where conventional rigid core CTs are unsuitable. This type of sensor may be used to measure AC current over a wide dynamic range and from 20 Hz to 5 kHz. It features a length of 47".




Dent CT-R36-A4-U RoCoil Flexible Current Transformer, 35" CT-R36-A4-U
Designed for accurate non-intrusive measurement of AC current, pulsed DC or distorted waveforms where conventional rigid core CTs are unsuitable. This type of sensor may be used to measure AC current over a wide dynamic range and from 20 Hz to 5 kHz. It features a length of 35".




Dent CT-R24-A4-U RoCoil Flexible Current Transformer, 24" CT-R24-A4U
Designed for accurate non-intrusive measurement of AC current, pulsed DC or distorted waveforms where conventional rigid core CTs are unsuitable. This type of sensor may be used to measure AC current over a wide dynamic range and from 20 Hz to 5 kHz. It features a length of 24".




Dent CT-R16-A4-U RoCoil Flexible Current Transformer, 16" CT-R16-A4U
Designed for accurate non-intrusive measurement of AC current, pulsed DC or distorted waveforms where conventional rigid core CTs are unsuitable. This type of sensor may be used to measure AC current over a wide dynamic range and from 20 Hz to 5 kHz. It features a length of 16".




Dent CT-CON-0150EZ-U Current Transformer CT-CON-0150EZ-U
Clamp-On Current Transformer. 1" (25Mm) Round Opening.




Dent CT-SCM-0400-U Medium Split Core Current Transformer, 400A CT-SCM-0400-U
Provides a linear output voltage that is proportional to the input current that is safe and easy to install over existing electrical power lines without disconnection or interruption. Features a window size of 1.25" and offers a 400A amp rating.




Dent CT-SCM-0600-U Medium Split Core Current Transformer, 600A CT-SCM-0600-U
Provides a linear output voltage that is proportional to the input current that is safe and easy to install over existing electrical power lines without disconnection or interruption. Features a window size of 1.25" and offers a 600A amp rating.




Dent CT-SCL-1000-U Large Split Core Current Transformer, 1000A CT-SCL-1000-U
Provides a linear output voltage that is proportional to the input current that is safe and easy to install over existing electrical power lines without disconnection or interruption. Features a window size of 2.0" and offers a 1000A amp rating.
















































Ask a question about Dent ElitePro EXC-I-N-C Energy Data Logger, Int'l, USB/Ethernet

Customer Reviews for the Dent EXC-I-N-C

More Dent Products

Calibration Lab