Delmhorst 43-E Electrode, Moisture, Clamp Type

Model: 43-E

Delmhorst 43-E Electrode, Moisture, Clamp Type

Model: 43-E

Clamp type for testing thin sheet stock. The sample tested is compressed between two smooth discs.

Clamp type for testing thin sheet stock. The sample tested is compressed between two smooth discs.

Your Price $325.00 USD
Availability 5 Days
Quantity

Delmhorst 43-E Offers

Features

  • Measures current up to 100Arms
  • Measures up to 600VAC/DC
  • Measures Hz on either V or A inputs
  • Measures Resistance and Continuity
  • Hold feature freezes Value
  • Max feature keeps track of highest measured In-rush value
  • Zero button ideal for measuring relative values
  • Filter to isolate 50/60Hz fundamental from harmonics
  • Compatible with VDE 0404

Specifications

  • mA AC Current (TRMS, Auto-Ranging)
  • Measurement Range: 0 to 600mA
  • Resolution: 60mA 0.01mA (10µA)
  • 600mA 0.1mA (100µA)
  • Accuracy: 50 to 60Hz 1.2% of Reading ± 5cts
  • 50 to 500Hz 2.5% of Reading ± 5cts
  • 500Hz to 3kHz 3.5% of Reading ± 10cts
  • AC Current (TRMS, Auto-Ranging)
  • Measurement Range: 10 to 100A
  • Resolution 10A 0.001A (1mA)
  • 100A 0.01A (10mA)
  • Accuracy: 50 to 60Hz 1.2% of Reading ± 5cts
  • 50 to 500Hz 2.5% of Reading ± 5cts
  • 500Hz to 3kHz 3.5% of Reading ± 10cts
  • AC Voltage (TRMS)
  • Measurement Range: 0 to 600V
  • Resolution 0.1V
  • Accuracy: 50 to 60Hz 1.0% of Reading ± 5cts
  • 50 to 500Hz 1.2% of Reading ± 5cts
  • 500Hz to 3kHz 2.5% of Reading ± 10cts
  • DC Voltage
  • Measurement Range: 0 to 600V
  • Resolution: 0.1V
  • Accuracy: 1.0% of Reading ± 3cts
  • Frequency (Auto-Ranging) Sensitivity: 10mArms min 5Vrms min
  • Accuracy: 0.5% of Reading ± 2cts
  • Resistance
  • Measurement Range: 0 to1kΩ
  • Resolution: 0.1Ω
  • Accuracy: 1.0% of Reading ± 3cts
  • Continuity
  • Measurement Range: 0 to1kΩ
  • Resolution: 0.1Ω
  • Buzzer: <35Ω ± 25Ω
  • Overload Protection: 660Vrms/150Arms Ð is displayed and buzzer will sound
  • Nominal Sample Rate: Two measurements per second (approx.)
  • MAX Sample Rate: 100ms
  • Filter On (50/60Hz only); Off (Full frequency range)
  • In-Rush Max: 100ms sample time
  • Power Source: Two 1.5V AAA batteries
  • Battery Life: 45 hrs (approx.)
  • Power-Off: 10 min approx with user override
  • Low Battery Indication: Displayed when battery voltage is low
  • Dimensions: 8.5 x 2.5 x 1.18" (218 x 64 x 30mm)
  • Jaw Opening: 1.10" (28mm)
  • Maximum Conductor Size: 1" (26mm)
  • Weight: 10 oz (280g) with batteries
  • Display Type: Four digit LCD
  • Backlight: LED with 180 sec Auto-OffAL
  • Operating Temperature: 32° to 104°F (0° to 40°C); <80% RH (non-condensing)
  • Storage Temperature: 14° to 140°F (-10° to 60°C); <70% RH (non-condensing)
  • Safety Rating: EN 61010-1 Ed. 2001, EN 61010-2-032 Ed. 2003, 600V, Cat. III
  • Double Insulation
  • CE Mark

What's included with the Delmhorst 43-E

  • Delmhorst 43-E Electrode, Moisture, Clamp Type

Ask a question about Delmhorst 43-E Electrode, Moisture, Clamp Type

Customer Reviews for the Delmhorst 43-E

Delmhorst 43-E Offers

Features

  • Measures current up to 100Arms
  • Measures up to 600VAC/DC
  • Measures Hz on either V or A inputs
  • Measures Resistance and Continuity
  • Hold feature freezes Value
  • Max feature keeps track of highest measured In-rush value
  • Zero button ideal for measuring relative values
  • Filter to isolate 50/60Hz fundamental from harmonics
  • Compatible with VDE 0404

Specifications

  • mA AC Current (TRMS, Auto-Ranging)
  • Measurement Range: 0 to 600mA
  • Resolution: 60mA 0.01mA (10µA)
  • 600mA 0.1mA (100µA)
  • Accuracy: 50 to 60Hz 1.2% of Reading ± 5cts
  • 50 to 500Hz 2.5% of Reading ± 5cts
  • 500Hz to 3kHz 3.5% of Reading ± 10cts
  • AC Current (TRMS, Auto-Ranging)
  • Measurement Range: 10 to 100A
  • Resolution 10A 0.001A (1mA)
  • 100A 0.01A (10mA)
  • Accuracy: 50 to 60Hz 1.2% of Reading ± 5cts
  • 50 to 500Hz 2.5% of Reading ± 5cts
  • 500Hz to 3kHz 3.5% of Reading ± 10cts
  • AC Voltage (TRMS)
  • Measurement Range: 0 to 600V
  • Resolution 0.1V
  • Accuracy: 50 to 60Hz 1.0% of Reading ± 5cts
  • 50 to 500Hz 1.2% of Reading ± 5cts
  • 500Hz to 3kHz 2.5% of Reading ± 10cts
  • DC Voltage
  • Measurement Range: 0 to 600V
  • Resolution: 0.1V
  • Accuracy: 1.0% of Reading ± 3cts
  • Frequency (Auto-Ranging) Sensitivity: 10mArms min 5Vrms min
  • Accuracy: 0.5% of Reading ± 2cts
  • Resistance
  • Measurement Range: 0 to1kΩ
  • Resolution: 0.1Ω
  • Accuracy: 1.0% of Reading ± 3cts
  • Continuity
  • Measurement Range: 0 to1kΩ
  • Resolution: 0.1Ω
  • Buzzer: <35Ω ± 25Ω
  • Overload Protection: 660Vrms/150Arms Ð is displayed and buzzer will sound
  • Nominal Sample Rate: Two measurements per second (approx.)
  • MAX Sample Rate: 100ms
  • Filter On (50/60Hz only); Off (Full frequency range)
  • In-Rush Max: 100ms sample time
  • Power Source: Two 1.5V AAA batteries
  • Battery Life: 45 hrs (approx.)
  • Power-Off: 10 min approx with user override
  • Low Battery Indication: Displayed when battery voltage is low
  • Dimensions: 8.5 x 2.5 x 1.18" (218 x 64 x 30mm)
  • Jaw Opening: 1.10" (28mm)
  • Maximum Conductor Size: 1" (26mm)
  • Weight: 10 oz (280g) with batteries
  • Display Type: Four digit LCD
  • Backlight: LED with 180 sec Auto-OffAL
  • Operating Temperature: 32° to 104°F (0° to 40°C); <80% RH (non-condensing)
  • Storage Temperature: 14° to 140°F (-10° to 60°C); <70% RH (non-condensing)
  • Safety Rating: EN 61010-1 Ed. 2001, EN 61010-2-032 Ed. 2003, 600V, Cat. III
  • Double Insulation
  • CE Mark

What's included with the Delmhorst 43-E

  • Delmhorst 43-E Electrode, Moisture, Clamp Type

Ask a question about Delmhorst 43-E Electrode, Moisture, Clamp Type