This multi-channel thermometer incorporates 4 discrete temperature channels with the temperature differential between any 2 of the 4 inputs, min/max, scan and data record functions. Powered by one 9V alkaline battery (included), the unit is designed for portability, yet can still be powered via an optional 110V power supply.
This multi-channel thermometer incorporates 4 discrete temperature channels with the temperature differential between any 2 of the 4 inputs, min/max, scan and data record functions. Powered by one 9V alkaline battery (included), the unit is designed for portability, yet can still be powered via an optional 110V power supply.
Discontinued!
This product has been discontinued and is no longer available. There are no replacement options.
We can help you find what you need:
Measurement capabilities include pressure, superheat, sub-cooling, relative humidity, wet bulb, dry bulb and dew point with a range of highly accurate, job-specific probes and sensors.
Features
Pressure Range | -14.7psig to 725psig (-100 to 5,000kPa) |
Pressure Accuracy | ±1% of reading or ±0.5psig (±3.5 kPa) |
Pressure Units | psig, kPa, bar, Hg, kg/cm2 |
Proof Pressure | 1,000psi (7,000KPa) |
Dew or Bubble Saturation Temperature | ±1.8°F (±1°C) |
Measurement Temperature Range | -40 to 300°F (-40 to 150°C) Actual temp range depends on the probe being used |
Temperature Resolution | ±0.1°F or °C |
Superheat/Subcool Accuracy | ±0.4°F/±0.2°C from 14 to 158°F (-10 to 70°C); 0.6°F/0.3°C elsewhere in the range |
RH Range | 0 to 100%RH |
RH Accuracy (TMX3RH) | ±1.8%RH from 10 to 90%RH; ±3% elsewhere in the range |
DB Accuracy (TMX3RH) | ±1.2% of reading ±1.0°F from -40 to 200°F (±1.2% of reading ±0.5°C from -40 to 90°C) |
Power Source | 9V alkaline battery or optional TMX3PS AC adapter for 100 to 240VAC (40 to 60Hz) - USA Plug |
Battery Life | 30hr continuous use |
Automatic Power Off | After 10 minutes of inactivity |
Dimensions | 12 x 10 x 3in (30.5 x 25.4 x 7.6cm) |
Weight | 3lb (1.4kg) with probes |
Warranty | 1 year |
Pressure Range | -14.7psig to 725psig (-100 to 5,000kPa) |
Pressure Accuracy | ±1% of reading or ±0.5psig (±3.5 kPa) |
Pressure Units | psig, kPa, bar, Hg, kg/cm2 |
Proof Pressure | 1,000psi (7,000KPa) |
Dew or Bubble Saturation Temperature | ±1.8°F (±1°C) |
Measurement Temperature Range | -40 to 300°F (-40 to 150°C) Actual temp range depends on the probe being used |
Temperature Resolution | ±0.1°F or °C |
Superheat/Subcool Accuracy | ±0.4°F/±0.2°C from 14 to 158°F (-10 to 70°C); 0.6°F/0.3°C elsewhere in the range |
RH Range | 0 to 100%RH |
RH Accuracy (TMX3RH) | ±1.8%RH from 10 to 90%RH; ±3% elsewhere in the range |
DB Accuracy (TMX3RH) | ±1.2% of reading ±1.0°F from -40 to 200°F (±1.2% of reading ±0.5°C from -40 to 90°C) |
Power Source | 9V alkaline battery or optional TMX3PS AC adapter for 100 to 240VAC (40 to 60Hz) - USA Plug |
Battery Life | 30hr continuous use |
Automatic Power Off | After 10 minutes of inactivity |
Dimensions | 12 x 10 x 3in (30.5 x 25.4 x 7.6cm) |
Weight | 3lb (1.4kg) with probes |
Warranty | 1 year |