Measure and monitor various industrial processes with this digital panel meter which features a high/low-limit display scale, AC frequency measurement, zero-point adjustment, and PV transmission output scale function. In addition, this meter features a 100 to 240 V AC ~ 50/60 Hz power supply and indicator output.
Measure and monitor various industrial processes with this digital panel meter which features a high/low-limit display scale, AC frequency measurement, zero-point adjustment, and PV transmission output scale function. In addition, this meter features a 100 to 240 V AC ~ 50/60 Hz power supply and indicator output.
Features
Input Type | DC current |
Maximum Allowable Input | 110% F.S. for each measured input range |
Display | Method: 4-digit 7-segment red LED Character height: 0.55" (14.2 mm) Maximum range: -1999 to 9999 Accuracy (Dependent on the ambient temperature): 73.4°F ±41°F (23°C ±5°C) - F.S. ±0.1% rdg ±2-digit, F.S. +0.3% rdg ±3-digit maximum only for 5 A terminal 14 to 122°F (-10 to 50°C) - F.S. ±0.5% rdg ±3-digit |
A/D Conversion Method | ΣΔ (Sigma Delta) A DC |
Sampling Cycle | 50 ms |
Preset Output | None (indicator)/relay/NPN open collector/PNP open collector output mode |
Relay | Contact capacity: 250 V AC 3 A, 30 V DC 3 A Contact composition: N.O (1a) |
NPN/PNP Open Collector | Output capacity: ≤12 to 24 V DC ±2 V DC, 50 mA resistive load |
Sub Output | None (indicator)/BCD dynamic/transmission (DC 4 to 20 mA)/low speed serial/RS485 communication output model |
BCD Dynamic/Low speed serial | NPN open collector output Output capacity: ≤12 to 24 V DC, 50 mA resistive load |
Transmission (DC 4 to 20 mA) | Resolution: 1/12,000 (load resistance: ≤600 Ω) Response time: ≤450 ms |
RS485 Communication | Protocol: Modbus RTU |
Insulation Resistance | Between external terminal and case: ≥100 MΩ (500 V DC megger) |
Dielectric Strength | Between external terminal and case: 2000 V AC 50/60 Hz for 1 minute |
Noise Immunity | ±2 kV square wave noise (pulse width: 1 μs) by the noise simulator |
Vibration | 0.029" (0.75 mm) double amplitude at frequency of 10 to 55 Hz (for 1 minute) in each X, Y, Z direction for 1 hour Malfunction: 0.019" (0.5 mm) double amplitude at frequency of 10 to 55 Hz (for 1 minute) in each X, Y, Z direction for 10 minute |
Shock | 300 m/s² (≈ 30 G) in each X, Y, Z direction for 3 times Malfunction: 100 m/s² (≈ 10 G) in each X, Y, Z direction for 3 times |
Input Specification | 0 to 5 A, 0 to 2 A, 0 to 500 mA, 0 to 200 mA, 0 to 50 mA, 4 to 20 mA, 0 to 5 mA, 0 to 2 mA |
Output | Main output (comparative value): Indicator |
Hold Function | Includes (external hold function) |
Environment | Ambient temperature: 14 to 122°F (-10 to 50°C), storage: -4 to 140°F (-20 to 60°C) Ambient humidity: 35 to 85% RH, storage: 35 to 85% RH |
Insulation Type | Double insulation or reinforced insulation (mark: dielectric strength between the measuring input part and the power part: 1 kV) |
Power | Supply: 100 to 240 V AC ~ 50/60 Hz Consumption: 5 V A |
Dimensions | 3.77 x 1.88" (96 x 48 mm) |
Weight | 0.29 lbs (134 g) |
Input Type | DC current |
Maximum Allowable Input | 110% F.S. for each measured input range |
Display | Method: 4-digit 7-segment red LED Character height: 0.55" (14.2 mm) Maximum range: -1999 to 9999 Accuracy (Dependent on the ambient temperature): 73.4°F ±41°F (23°C ±5°C) - F.S. ±0.1% rdg ±2-digit, F.S. +0.3% rdg ±3-digit maximum only for 5 A terminal 14 to 122°F (-10 to 50°C) - F.S. ±0.5% rdg ±3-digit |
A/D Conversion Method | ΣΔ (Sigma Delta) A DC |
Sampling Cycle | 50 ms |
Preset Output | None (indicator)/relay/NPN open collector/PNP open collector output mode |
Relay | Contact capacity: 250 V AC 3 A, 30 V DC 3 A Contact composition: N.O (1a) |
NPN/PNP Open Collector | Output capacity: ≤12 to 24 V DC ±2 V DC, 50 mA resistive load |
Sub Output | None (indicator)/BCD dynamic/transmission (DC 4 to 20 mA)/low speed serial/RS485 communication output model |
BCD Dynamic/Low speed serial | NPN open collector output Output capacity: ≤12 to 24 V DC, 50 mA resistive load |
Transmission (DC 4 to 20 mA) | Resolution: 1/12,000 (load resistance: ≤600 Ω) Response time: ≤450 ms |
RS485 Communication | Protocol: Modbus RTU |
Insulation Resistance | Between external terminal and case: ≥100 MΩ (500 V DC megger) |
Dielectric Strength | Between external terminal and case: 2000 V AC 50/60 Hz for 1 minute |
Noise Immunity | ±2 kV square wave noise (pulse width: 1 μs) by the noise simulator |
Vibration | 0.029" (0.75 mm) double amplitude at frequency of 10 to 55 Hz (for 1 minute) in each X, Y, Z direction for 1 hour Malfunction: 0.019" (0.5 mm) double amplitude at frequency of 10 to 55 Hz (for 1 minute) in each X, Y, Z direction for 10 minute |
Shock | 300 m/s² (≈ 30 G) in each X, Y, Z direction for 3 times Malfunction: 100 m/s² (≈ 10 G) in each X, Y, Z direction for 3 times |
Input Specification | 0 to 5 A, 0 to 2 A, 0 to 500 mA, 0 to 200 mA, 0 to 50 mA, 4 to 20 mA, 0 to 5 mA, 0 to 2 mA |
Output | Main output (comparative value): Indicator |
Hold Function | Includes (external hold function) |
Environment | Ambient temperature: 14 to 122°F (-10 to 50°C), storage: -4 to 140°F (-20 to 60°C) Ambient humidity: 35 to 85% RH, storage: 35 to 85% RH |
Insulation Type | Double insulation or reinforced insulation (mark: dielectric strength between the measuring input part and the power part: 1 kV) |
Power | Supply: 100 to 240 V AC ~ 50/60 Hz Consumption: 5 V A |
Dimensions | 3.77 x 1.88" (96 x 48 mm) |
Weight | 0.29 lbs (134 g) |