Autonics MT4W Series Digital Panel Meter, 100 to 240 V AC/50/60 Hz, 3 relay/4 to 20 mA outputs

Model: MT4W-DA-40

Autonics MT4W Series Digital Panel Meter, 100 to 240 V AC/50/60 Hz, 3 relay/4 to 20 mA outputs

Model: MT4W-DA-40

Measure and monitor many industrial processes with this panel meter which features a high/low-limit display scale, AC frequency measurement, zero-point adjustment, and PV transmission output scale function. In addition, this meter features a 100 to 240 V AC ~ 50/60 Hz power supply, 4 to 20 mA, and three relay outputs.

Measure and monitor many industrial processes with this panel meter which features a high/low-limit display scale, AC frequency measurement, zero-point adjustment, and PV transmission output scale function. In addition, this meter features a 100 to 240 V AC ~ 50/60 Hz power supply, 4 to 20 mA, and three relay outputs.

Your Price $216.00 USD
Availability 2 to 3 Weeks
Quantity

Autonics MT4W-DA-40 Offers

Features

  • Display method: frequency; It measures input signal frequency when it is AC input
  • High-limit display value gradient correction; This function is to correct a gradient of high/low-limit scale value and also can be used as correction function of high-limit scale value
  • High/low-limit scale value; This function is to display setting of particular high/low-limit value in order to display high/low-limit value of measured input
  • Zero adjustment; It adjusts the display value of the optional configured input value as zero by force
  • Error correction; It corrects display value error of measured input
  • Startup compensation time; This time function limits the operation of an output until the measured input (overvoltage or inrush current) is stable at moment of power on, all outputs are OFF during startup compensation time setting after power is applied
  • Display cycle; In some applications the measured input may fluctuate which in turn causes the display to fluctuate, by adjusting the display cycle delay function time the operator can adjust the display time
  • Maximum/minimum peak value; It monitors maximum/minimum peak value of display value based on the current displays value and then displays the data at the parameters
  • Transmission (DC 4 to 20 mA) output scale adjustment; It sets transmission output for the display value at the output current DC 4 to 20 mA and it sets display value for 4 mA at low-limit value of transmission output and 20 mA at high-limit value of transmission output
  • Output operation mode; H.SET or L.SET is displayed according to the output operation mode setting, in case of output operation mode as OFF, H.SET and L.SET are not displayed

Autonics MT4W-DA-40 Specifications

Input Type DC current
Maximum Allowable Input 110% F.S. for each measured input range
Display Method: 4-digit 7-segment red LED
Character height: 0.55" (14.2 mm)
Maximum range: -1999 to 9999

Accuracy (Dependent on the ambient temperature):
73.4°F ±41°F (23°C ±5°C) - F.S. ±0.1% rdg ±2-digit, F.S. +0.3% rdg ±3-digit maximum only for 5 A terminal
14 to 122°F (-10 to 50°C) - F.S. ±0.5% rdg ±3-digit
A/D Conversion Method ΣΔ (Sigma Delta) A DC
Sampling Cycle 50 ms
Preset Output None (indicator)/relay/NPN open collector/PNP open collector output mode
Relay Contact capacity: 250 V AC 3 A, 30 V DC 3 A
Contact composition: N.O (1a)
NPN/PNP Open Collector Output capacity: ≤12 to 24 V DC ±2 V DC, 50 mA resistive load
Sub Output None (indicator)/BCD dynamic/transmission (DC 4 to 20 mA)/low speed serial/RS485 communication output model
BCD Dynamic/Low speed serial NPN open collector output
Output capacity: ≤12 to 24 V DC, 50 mA resistive load
Transmission (DC 4 to 20 mA) Resolution: 1/12,000 (load resistance: ≤600 Ω)
Response time: ≤450 ms
RS485 Communication Protocol: Modbus RTU
Insulation Resistance Between external terminal and case: ≥100 MΩ (500 V DC megger)
Dielectric Strength Between external terminal and case: 2000 V AC 50/60 Hz for 1 minute
Noise Immunity ±2 kV square wave noise (pulse width: 1 μs) by the noise simulator
Vibration 0.029" (0.75 mm) double amplitude at frequency of 10 to 55 Hz (for 1 minute) in each X, Y, Z direction for 1 hour
Malfunction: 0.019" (0.5 mm) double amplitude at frequency of 10 to 55 Hz (for 1 minute) in each X, Y, Z direction for 10 minute
Shock 300 m/s² (≈ 30 G) in each X, Y, Z direction for 3 times
Malfunction: 100 m/s² (≈ 10 G) in each X, Y, Z direction for 3 times
Input Specification 0 to 5 A, 0 to 2 A, 0 to 500 mA, 0 to 200 mA, 0 to 50 mA, 4 to 20 mA, 0 to 5 mA, 0 to 2 mA
Output Main output (comparative value): Relay (hi, go, lo)
Sub output (display value) PV transmission (DC 4 to 20 mA)
Hold Function Includes (external hold function)
Environment Ambient temperature: 14 to 122°F (-10 to 50°C), storage: -4 to 140°F (-20 to 60°C)
Ambient humidity: 35 to 85% RH, storage: 35 to 85% RH
Insulation Type Double insulation or reinforced insulation (mark: dielectric strength between the measuring input part and the power part: 1 kV)
Power Supply: 100 to 240 V AC ~ 50/60 Hz
Consumption: 5 V A
Dimensions 3.77 x 1.88" (96 x 48 mm)
Weight 0.29 lbs (134 g)

What's included with the Autonics MT4W-DA-40

  • Panel Meter
  • 2 x Bracket
  • Unit Sticker
  • Instruction Manual

Ask a question about Autonics MT4W Series Digital Panel Meter, 100 to 240 V AC/50/60 Hz, 3 relay/4 to 20 mA outputs

Customer Reviews for the Autonics MT4W-DA-40

Autonics MT4W-DA-40 Offers

Features

  • Display method: frequency; It measures input signal frequency when it is AC input
  • High-limit display value gradient correction; This function is to correct a gradient of high/low-limit scale value and also can be used as correction function of high-limit scale value
  • High/low-limit scale value; This function is to display setting of particular high/low-limit value in order to display high/low-limit value of measured input
  • Zero adjustment; It adjusts the display value of the optional configured input value as zero by force
  • Error correction; It corrects display value error of measured input
  • Startup compensation time; This time function limits the operation of an output until the measured input (overvoltage or inrush current) is stable at moment of power on, all outputs are OFF during startup compensation time setting after power is applied
  • Display cycle; In some applications the measured input may fluctuate which in turn causes the display to fluctuate, by adjusting the display cycle delay function time the operator can adjust the display time
  • Maximum/minimum peak value; It monitors maximum/minimum peak value of display value based on the current displays value and then displays the data at the parameters
  • Transmission (DC 4 to 20 mA) output scale adjustment; It sets transmission output for the display value at the output current DC 4 to 20 mA and it sets display value for 4 mA at low-limit value of transmission output and 20 mA at high-limit value of transmission output
  • Output operation mode; H.SET or L.SET is displayed according to the output operation mode setting, in case of output operation mode as OFF, H.SET and L.SET are not displayed

Autonics MT4W-DA-40 Specifications

Input Type DC current
Maximum Allowable Input 110% F.S. for each measured input range
Display Method: 4-digit 7-segment red LED
Character height: 0.55" (14.2 mm)
Maximum range: -1999 to 9999

Accuracy (Dependent on the ambient temperature):
73.4°F ±41°F (23°C ±5°C) - F.S. ±0.1% rdg ±2-digit, F.S. +0.3% rdg ±3-digit maximum only for 5 A terminal
14 to 122°F (-10 to 50°C) - F.S. ±0.5% rdg ±3-digit
A/D Conversion Method ΣΔ (Sigma Delta) A DC
Sampling Cycle 50 ms
Preset Output None (indicator)/relay/NPN open collector/PNP open collector output mode
Relay Contact capacity: 250 V AC 3 A, 30 V DC 3 A
Contact composition: N.O (1a)
NPN/PNP Open Collector Output capacity: ≤12 to 24 V DC ±2 V DC, 50 mA resistive load
Sub Output None (indicator)/BCD dynamic/transmission (DC 4 to 20 mA)/low speed serial/RS485 communication output model
BCD Dynamic/Low speed serial NPN open collector output
Output capacity: ≤12 to 24 V DC, 50 mA resistive load
Transmission (DC 4 to 20 mA) Resolution: 1/12,000 (load resistance: ≤600 Ω)
Response time: ≤450 ms
RS485 Communication Protocol: Modbus RTU
Insulation Resistance Between external terminal and case: ≥100 MΩ (500 V DC megger)
Dielectric Strength Between external terminal and case: 2000 V AC 50/60 Hz for 1 minute
Noise Immunity ±2 kV square wave noise (pulse width: 1 μs) by the noise simulator
Vibration 0.029" (0.75 mm) double amplitude at frequency of 10 to 55 Hz (for 1 minute) in each X, Y, Z direction for 1 hour
Malfunction: 0.019" (0.5 mm) double amplitude at frequency of 10 to 55 Hz (for 1 minute) in each X, Y, Z direction for 10 minute
Shock 300 m/s² (≈ 30 G) in each X, Y, Z direction for 3 times
Malfunction: 100 m/s² (≈ 10 G) in each X, Y, Z direction for 3 times
Input Specification 0 to 5 A, 0 to 2 A, 0 to 500 mA, 0 to 200 mA, 0 to 50 mA, 4 to 20 mA, 0 to 5 mA, 0 to 2 mA
Output Main output (comparative value): Relay (hi, go, lo)
Sub output (display value) PV transmission (DC 4 to 20 mA)
Hold Function Includes (external hold function)
Environment Ambient temperature: 14 to 122°F (-10 to 50°C), storage: -4 to 140°F (-20 to 60°C)
Ambient humidity: 35 to 85% RH, storage: 35 to 85% RH
Insulation Type Double insulation or reinforced insulation (mark: dielectric strength between the measuring input part and the power part: 1 kV)
Power Supply: 100 to 240 V AC ~ 50/60 Hz
Consumption: 5 V A
Dimensions 3.77 x 1.88" (96 x 48 mm)
Weight 0.29 lbs (134 g)

What's included with the Autonics MT4W-DA-40

  • Panel Meter
  • 2 x Bracket
  • Unit Sticker
  • Instruction Manual

Ask a question about Autonics MT4W Series Digital Panel Meter, 100 to 240 V AC/50/60 Hz, 3 relay/4 to 20 mA outputs

Customer Reviews for the Autonics MT4W-DA-40