Electrical Specifications | |
Temperature Scale | Celsius or Fahrenheit user-selectable |
Measurement Range | Pt385 (100&Ohm;) -328 to 1472°F (-200 to 800°C) Pt3916/Pt3926 (100&Ohm;) -328 to 1166°F (-200 to 630°C) |
Resolution | 0.2°F or 0.1°C |
Accuracy | Accuracy is specified for operating temperatures over the range of 64 to 82°F (18 to 28°C), for 1 year, not including thermocouple error. ±(0.05% rdg +0.2°C) on °C scale ±(0.05% rdg+0.4°F) on °F scale |
Temperature | 0.1 times the applicable accuracy |
Coefficient | Specification per °C from 32 to 64°F and 82 to 122°F (0 to 18°C and 28 to 50°C) |
Input Protection | 24 V DC or 24 V AC rms maximum input voltage on any combination of input pins |
Input | Accepts for 3 wires or 4 wires Mini-Din |
Connector | Plug and the meter is designed for standard. The other probes 2.3 wires will cause measuring tolerance due to cable resistance |
General Specifications | |
Frequency Range | 910 to 920 MHz Low current consumption less than 1 mA The transmitting distance can reach 25 m without magnetic interference |
Display | 4½ digit liquid crystal display (LCD) with maximum reading of 19999 |
Polarity | Automatic, positive implied, negative polarity indication |
Measurement Rate | 1 times/second |
Auto Power Off | 30 minutes |
Environment | Operating: 32 to 122°F (0 to 50°C) at <70% R.H. Storage: -4 to 140°F (-20 to 60°C), 0 to 80% R.H. with battery removed from meter |
Accuracy | Stated accuracy at 23°C ±5°C, <75% R.H. |
Battery | 1.5 V x 4 pcs AAA size |
Battery Life | 200 hours typical |
Dimensions | 9.5 x 6.22 x 3" (241.3 x 158 x 76.2 mm) |
Weight | Approximately 0.67 lbs (304 g) including batteries and packaging box |
Electrical Specifications | |
Temperature Scale | Celsius or Fahrenheit user-selectable |
Measurement Range | Pt385 (100&Ohm;) -328 to 1472°F (-200 to 800°C) Pt3916/Pt3926 (100&Ohm;) -328 to 1166°F (-200 to 630°C) |
Resolution | 0.2°F or 0.1°C |
Accuracy | Accuracy is specified for operating temperatures over the range of 64 to 82°F (18 to 28°C), for 1 year, not including thermocouple error. ±(0.05% rdg +0.2°C) on °C scale ±(0.05% rdg+0.4°F) on °F scale |
Temperature | 0.1 times the applicable accuracy |
Coefficient | Specification per °C from 32 to 64°F and 82 to 122°F (0 to 18°C and 28 to 50°C) |
Input Protection | 24 V DC or 24 V AC rms maximum input voltage on any combination of input pins |
Input | Accepts for 3 wires or 4 wires Mini-Din |
Connector | Plug and the meter is designed for standard. The other probes 2.3 wires will cause measuring tolerance due to cable resistance |
General Specifications | |
Frequency Range | 910 to 920 MHz Low current consumption less than 1 mA The transmitting distance can reach 25 m without magnetic interference |
Display | 4½ digit liquid crystal display (LCD) with maximum reading of 19999 |
Polarity | Automatic, positive implied, negative polarity indication |
Measurement Rate | 1 times/second |
Auto Power Off | 30 minutes |
Environment | Operating: 32 to 122°F (0 to 50°C) at <70% R.H. Storage: -4 to 140°F (-20 to 60°C), 0 to 80% R.H. with battery removed from meter |
Accuracy | Stated accuracy at 23°C ±5°C, <75% R.H. |
Battery | 1.5 V x 4 pcs AAA size |
Battery Life | 200 hours typical |
Dimensions | 9.5 x 6.22 x 3" (241.3 x 158 x 76.2 mm) |