Ideal for industrial process applications, this digital RTD thermometer features a dual input function and a resolution of 0.2°F (0.1°C). Additionally, it maintains stability for many years while offering greater accuracy when compared to thermocouples.
Ideal for industrial process applications, this digital RTD thermometer features a dual input function and a resolution of 0.2°F (0.1°C). Additionally, it maintains stability for many years while offering greater accuracy when compared to thermocouples.
The RTD probes are preferred for industrial process applications.
They typically provide higher accuracy than thermocouples and maintain stability for many years.
Features
Applications
Electrical Specifications | |
Temperature Scale | Fahrenheit or Celsius user-selectable |
Measurement Range | Pt385 (100Ω): -328 to 1472°F (-200 to 800°C) Pt3916/Pt3926 (100Ω): -328 to 1166°F (-200 to 630°C) |
Resolution | 0.2°F or 0.1°C |
Accuracy | Accuracy is specified for operating temperatures over the range of 64 to 82°F (18 to 28°C), for 1 year (not including thermocouple error) ±(0.05%rdg+0.4°F) on °F scale and ±(0.05%rdg+0.2°C) on °C scale |
Temperature | 0.1 times the applicable accuracy |
Coefficient | Specification per °F: 32 to 64°F and 82 to 122°F (°C: from 0 to 18°C and 28 to 50°C) |
Input | Accepts for 3 wires or 4 wires Mini-Din Protection: 24 V DC or 24 V aAC rms maximum input voltage on any combination of input pins |
Connector | Plug and the meter is designed for standard. The other probes 2.3 wires will cause measuring tolerance due to cable resistance |
General Specifications | |
Display | 4½ digit liquid crystal display (LCD) with maximum reading of 19999 |
Polarity | Automatic, positive implied, negative polarity indication |
Low Battery Indication | Displayed when the battery voltage drops below the operating level |
Measurement Rate | 1 times/second |
Auto Power Off | 30 minutes |
Accuracy | Stated accuracy at 23°C ±5°C, <75% R.H. |
Battery | 4 x AAA 1.5 V Battery life: 200 hours typical |
Environmental Conditions | Operating: 32 to 122°F (0 to 50°C) at <70% R.H. Storage: -4 to 140°F (-20 to 60°C), 0 to 80% R.H. with battery removed from meter |
Dimensions | 9.5 x 6.22 x 3" (241.3 x 158 x 76.2 mm) |
Weight | 0.63 lbs (285.76 g) approximatelly, including batteries and packaging box |
Electrical Specifications | |
Temperature Scale | Fahrenheit or Celsius user-selectable |
Measurement Range | Pt385 (100Ω): -328 to 1472°F (-200 to 800°C) Pt3916/Pt3926 (100Ω): -328 to 1166°F (-200 to 630°C) |
Resolution | 0.2°F or 0.1°C |
Accuracy | Accuracy is specified for operating temperatures over the range of 64 to 82°F (18 to 28°C), for 1 year (not including thermocouple error) ±(0.05%rdg+0.4°F) on °F scale and ±(0.05%rdg+0.2°C) on °C scale |
Temperature | 0.1 times the applicable accuracy |
Coefficient | Specification per °F: 32 to 64°F and 82 to 122°F (°C: from 0 to 18°C and 28 to 50°C) |
Input | Accepts for 3 wires or 4 wires Mini-Din Protection: 24 V DC or 24 V aAC rms maximum input voltage on any combination of input pins |
Connector | Plug and the meter is designed for standard. The other probes 2.3 wires will cause measuring tolerance due to cable resistance |
General Specifications | |
Display | 4½ digit liquid crystal display (LCD) with maximum reading of 19999 |
Polarity | Automatic, positive implied, negative polarity indication |
Low Battery Indication | Displayed when the battery voltage drops below the operating level |
Measurement Rate | 1 times/second |
Auto Power Off | 30 minutes |
Accuracy | Stated accuracy at 23°C ±5°C, <75% R.H. |
Battery | 4 x AAA 1.5 V Battery life: 200 hours typical |
Environmental Conditions | Operating: 32 to 122°F (0 to 50°C) at <70% R.H. Storage: -4 to 140°F (-20 to 60°C), 0 to 80% R.H. with battery removed from meter |
Dimensions | 9.5 x 6.22 x 3" (241.3 x 158 x 76.2 mm) |
Weight | 0.63 lbs (285.76 g) approximatelly, including batteries and packaging box |