TSI/Alnor AXD620 Compact Micromanometer

Model: AXD620

TSI/Alnor AXD620 Compact Micromanometer

Model: AXD620

Sale Price $959.00 USD
Regular Price $1065.00 USD
Availability 4 to 5 Weeks
Quantity

Traceable In-House Calibration Certificate for your AXD620 Compact Micromanometer

Traceable In-House Calibration Certificate for your AXD620 Compact Micromanometer

TSI/Alnor AXD620 Offers

With its compact and rugged design, this comprehensive micromanometer is ideal for pressure measurements. With the pitot tubes, the unit can measure velocity and also calculate flow rates with user–input duct size and shape.

Features

  • Measure differential and static pressure from -15 to 15 inH2O (-3735 to 3735 Pa)
  • Calculates and displays velocity when using a pitot tube (sold separately)
  • Calculates volumetric flow rate in duct from velocity and user-input duct size and shape
  • Records data points in duct traverse using sampling function
  • Data logging with time and date stamp
  • Programmable K factor
  • Preset up to 5 round and rectangular duct sizes
  • Data logging with time and date stamp

Applications

  • HVAC/R commissioning and troubleshooting
  • Testing and balancing
  • Pitot tube duct traverses
  • Static pressure measurements
  • Differential pressure measurements

TSI/Alnor AXD620 Specifications

Static/Differential Pressure Range: -15 to 15 inH2O (-28 to 28 mmHg, -3735 to 3735 Pa)
Accuracy: ±1% of reading ±0.005 inH2O (±1 Pa, ±0.01 mmHg)
Resolution: 0.001 inH2O (0.1 Pa, 0.01 mmHg)
Velocity From a Pitot Tube Range: 250 to 15,500 ft/min (1.27 to 78.7 m/s)
Accuracy: ±1.5% at 2000 ft/min (10.16 m/s)
Resolution: 1 ft/min (0.1 m/s)
Duct Size Dimensions 1 to 250” in increments of 0.1” (1 to 635 cm in increments of 0.1 cm)
Volumetric Flow Rate Actual range is a function of velocity, pressure, duct size, and K factor
Temperature Range Operating: 40 to 113°F (5 to 45°C)
Storage: -4 to 140°F (-20 to 60°C)
Data Storage Capabilities 12,700+ samples and 100 test IDs
Logging Interval 1 second to 1 hour
Time Constant User selectable
Power Requirement 4 x AA-size batteries or AC adapter
Dimensions 3.3 x 7.0 x 1.8” (8.4 x 17.8 x 4.4 cm)
Weight 0.6 lbs (0.27 kg)
Click here for complete specifications on the TSI/Alnor AXD620

What's included with the TSI/Alnor AXD620

  • Micromanometer
  • NIST Calibration Certificate
  • Pressure Tubing
  • 2 x Rubber Tubes
  • Static Pressure Tip
  • USB Cable
  • 4 x Alkaline Batteries
  • Carrying Case
  • CD-ROM with LogDat2™ Downloading Software
  • Operation and Service Manual

Ask a question about TSI/Alnor AXD620 Compact Micromanometer

Customer Reviews for the TSI/Alnor AXD620

TSI/Alnor AXD620 Offers

With its compact and rugged design, this comprehensive micromanometer is ideal for pressure measurements. With the pitot tubes, the unit can measure velocity and also calculate flow rates with user–input duct size and shape.

Features

  • Measure differential and static pressure from -15 to 15 inH2O (-3735 to 3735 Pa)
  • Calculates and displays velocity when using a pitot tube (sold separately)
  • Calculates volumetric flow rate in duct from velocity and user-input duct size and shape
  • Records data points in duct traverse using sampling function
  • Data logging with time and date stamp
  • Programmable K factor
  • Preset up to 5 round and rectangular duct sizes
  • Data logging with time and date stamp

Applications

  • HVAC/R commissioning and troubleshooting
  • Testing and balancing
  • Pitot tube duct traverses
  • Static pressure measurements
  • Differential pressure measurements

TSI/Alnor AXD620 Specifications

Static/Differential Pressure Range: -15 to 15 inH2O (-28 to 28 mmHg, -3735 to 3735 Pa)
Accuracy: ±1% of reading ±0.005 inH2O (±1 Pa, ±0.01 mmHg)
Resolution: 0.001 inH2O (0.1 Pa, 0.01 mmHg)
Velocity From a Pitot Tube Range: 250 to 15,500 ft/min (1.27 to 78.7 m/s)
Accuracy: ±1.5% at 2000 ft/min (10.16 m/s)
Resolution: 1 ft/min (0.1 m/s)
Duct Size Dimensions 1 to 250” in increments of 0.1” (1 to 635 cm in increments of 0.1 cm)
Volumetric Flow Rate Actual range is a function of velocity, pressure, duct size, and K factor
Temperature Range Operating: 40 to 113°F (5 to 45°C)
Storage: -4 to 140°F (-20 to 60°C)
Data Storage Capabilities 12,700+ samples and 100 test IDs
Logging Interval 1 second to 1 hour
Time Constant User selectable
Power Requirement 4 x AA-size batteries or AC adapter
Dimensions 3.3 x 7.0 x 1.8” (8.4 x 17.8 x 4.4 cm)
Weight 0.6 lbs (0.27 kg)
Click here for complete specifications on the TSI/Alnor AXD620

What's included with the TSI/Alnor AXD620

  • Micromanometer
  • NIST Calibration Certificate
  • Pressure Tubing
  • 2 x Rubber Tubes
  • Static Pressure Tip
  • USB Cable
  • 4 x Alkaline Batteries
  • Carrying Case
  • CD-ROM with LogDat2™ Downloading Software
  • Operation and Service Manual

Ask a question about TSI/Alnor AXD620 Compact Micromanometer

Customer Reviews for the TSI/Alnor AXD620

More TSI/Alnor Products

Calibration Lab