This Current Probe is designed for use in utility and industrial environments. The unique ergonomic design allows it to easily clamp onto cables or small bus bars. It is assembled to the highest safety and performance standards including the CE Mark and is UL approved for Canada and United States.
This Current Probe is designed for use in utility and industrial environments. The unique ergonomic design allows it to easily clamp onto cables or small bus bars. It is assembled to the highest safety and performance standards including the CE Mark and is UL approved for Canada and United States.
This AC Current probe is range selectable and offers 3 switch selectable ranges of 20, 200 or 2000AAC. Measurement range of 100mA to 1200A AC. Large jaw opening accommodates conductors up to two 500MCM conductors. This probe has a voltage output proportional at the current measured in the jaw of the probe. The SR661 has an integral 6.5 ft (1.98m) lead terminated by BNC connector. The high accuracy and wide frequency response makes this probe an excellent choice for use with oscilloscopes.
Features
Applications
Nominal Range | 20Apk, 200Apk, 2000Apk |
Measurement Range | 0.1 to 2000Apk |
Transformation Ratio | Voltage output |
Output Signal | mV output signal (2V Peak max), 3 range switch selectable on handle 100mV/A: 10mA to 20A Peak 10mV/A: 0.1A to 200A Peak 1mV/A: 1A to 2000A Peak |
Accuracy (10A Range) | 0.1 to 12A: ≤3% ± 10mV |
Phase Shift (10A Range) | 2 to 10A: ≤15°; 10 to 12A: ≤15° |
Accuracy (100A Range) | 0.1 to 120A: ≤2% ± 5mV |
Phase Shift (100A Range) | 5 to 20A: ≤15° 20 to 100A: ≤10° 100 to 120A: ≤5° |
Accuracy (1000A Range) | 1 to 1200A: ≤1% ± 1mV |
Phase Shift (1000A Range) | 50 to 200A: ≤3° 200 to 1000A: ≤2° 1000 to 1200A: ≤1° |
Overload | 12A and 120A continuous/1200A for 40 min ON, 20 min OFF |
Frequency Range | 1Hz to 100kHz (at -3dB) See typical response curves |
Load Impedance | 1MΩ at 47 pF |
Working/Common Mode Voltage | 600V Cat. III |
Output Termination | 6.5ft BNC |
Nominal Range | 20Apk, 200Apk, 2000Apk |
Measurement Range | 0.1 to 2000Apk |
Transformation Ratio | Voltage output |
Output Signal | mV output signal (2V Peak max), 3 range switch selectable on handle 100mV/A: 10mA to 20A Peak 10mV/A: 0.1A to 200A Peak 1mV/A: 1A to 2000A Peak |
Accuracy (10A Range) | 0.1 to 12A: ≤3% ± 10mV |
Phase Shift (10A Range) | 2 to 10A: ≤15°; 10 to 12A: ≤15° |
Accuracy (100A Range) | 0.1 to 120A: ≤2% ± 5mV |
Phase Shift (100A Range) | 5 to 20A: ≤15° 20 to 100A: ≤10° 100 to 120A: ≤5° |
Accuracy (1000A Range) | 1 to 1200A: ≤1% ± 1mV |
Phase Shift (1000A Range) | 50 to 200A: ≤3° 200 to 1000A: ≤2° 1000 to 1200A: ≤1° |
Overload | 12A and 120A continuous/1200A for 40 min ON, 20 min OFF |
Frequency Range | 1Hz to 100kHz (at -3dB) See typical response curves |
Load Impedance | 1MΩ at 47 pF |
Working/Common Mode Voltage | 600V Cat. III |
Output Termination | 6.5ft BNC |