AEMC PEL 103 Power/Energy Data Logger Kit with LCD

Model: PEL 103 | Order No: 2137.52 | UPC: 685338220476

AEMC PEL 103 Power/Energy Data Logger Kit with LCD

Model: PEL 103 | Order No: 2137.52 | UPC: 685338220476

Innovative and reliable, this single-, dual- (split-phase) and three-phase power/energy data logger accurately measures, records, and analyzes vital energy data for 50 Hz, 60 Hz, 400 Hz, and DC distribution systems. Ideal for system monitoring, this data logger has USB, LAN, Ethernet, and Bluetooth communications.

Innovative and reliable, this single-, dual- (split-phase) and three-phase power/energy data logger accurately measures, records, and analyzes vital energy data for 50 Hz, 60 Hz, 400 Hz, and DC distribution systems. Ideal for system monitoring, this data logger has USB, LAN, Ethernet, and Bluetooth communications.

Sale Price $2370.25 USD
Regular Price $2495.00 USD
Availability 6 to 7 Weeks
Quantity

AEMC Instruments PEL 103 Offers

Energy costs can be calculated and displayed quickly and easily by simply inputting the unit cost for a kilowatt hour into the software. Data is stored on a removable SD card. Data can be retrieved using a USB, Bluetooth and/or Ethernet (local or internet) connection by transporting the SD card back to a PC. The comprehensive DataView®software (included) provides the ability to view data from several hundred PEL 100 series instruments on a local network or over the internet allowing the user to evaluate energy usage in a department or facility basis, a remote site, or even in a city, anywhere in the world. DataView®allows measurements to be viewed in real-time on a PC and stored data to be downloaded for analysis and report generation.

Features

  • Measurement of RMS voltages and currents at 128 times per cycle and stored every second
  • Measurement of VA, W and var power values (total and per phase) stored every second
  • Measurement of VAh, Wh and varh energy values (total and per phase) per second with source/load indication
  • Calculation of the cos φ Displacement Power Factor (DPF) and the Power Factor (PF) stored every second
  • Calculation of Total Harmonic Distortion (THD)
  • Measurement, calculation and display of the harmonics up to the 50th order for 50/60 Hz and 7th order for 400Hz
  • Measurement of the DC quantities (RMS calculation)
  • Display Measurements
  • Electrical network quantities are stored on a removable SD-Card
  • Automatic recognition of the connected current sensors
  • DataView software for configuration, data retrieval and real-time viewing of measurements with a PC
  • Compact and rugged case
  • Versatile communication interface choices built in (USB, Ethernet, Bluetooth)

Applications

  • Measure efficiency, find areas for potential savings
  • Track Sub-billing occupants for energy costs
  • Assign energy costs to departments or operations within a department
  • Track peak demand periods and find opportunities for surcharge reductions
  • Determine present capacity and circumvent unnecessary electrical expansion costs
  • Verify the reliability and operation of electrical machinery
  • Improve response time to solve power related problems
  • Track energy availability and reliability of supply
  • Reduce field service time at sub-stations

AEMC Instruments PEL 103 Specifications

General
Sampling Frequency 128 samples per cycle; 50/60Hz (16 samples/cycle 400Hz)
Data Storage Rate 1 per second
Demand Period Storage Rate User selectable (1, 2, 3, 4, 5, 6, 10, 12, 15, 20, 30 and 60 minutes)
Recorded Parameters (Single- and Poly-Phase) V, I, W, VA, var, PF, Tan, Wh, Vah, varh, THD (V and I)
Individual harmonics (from 1 through 50 per phase); Crest Factor (CF), Cos f/DPF
Event Log Tracks and records status changes and error messages along with recorded data
Front Panel Indicator LEDs Bluetooth active, recording in progress, phase connection reversal, overload, battery charging and SD Card status
Storage Capacity 2GB SD card (included) is used for storage. SD cards (up to 2GB); SDHC cards (4 to 32GB) formatted FAT32 are supported
Inputs Voltage: 3 voltage input channels via 4mm safety banana jacks
Current: 3 current input channels via custom 4 pin jacks that accept AEMC® probes and sensors
Mechanical
Communication Ports USB 2.0, Ethernet (RJ45), Wireless Bluetooth Class
Case and Index of Protection Double insulated, rubber over-molded, polycarbonate UL94 V1 rated
IP54 non operating
Mounting and Security Embedded magnets on back side, keyhole slot on back side
Kensington anti-theft system
Safety Rating and CE Rating Complies with IEC 61010-1:Ed3, and IEC 61010-2-030:Ed1 for 1000 V CAT III
600 V CAT IV, Pollution Degree 2, yes
Dimensions 10.08 x 4.92 x 1.46" (256 x 125 x 37mm)
Weight 2.2 lbs (1 kg)
Click here for complete specifications on the AEMC Instruments PEL 103

What's included with the AEMC Instruments PEL 103

  • Power and Energy Logger
  • 3 x Sensors
  • 4 x Black Test Leads
  • Alligator Clips
  • 12 x Color-Coded ID Markers
  • 8 GB SD-CArd with USB-SD-Card Reader
  • USB Drive
  • USB Cable
  • Power Cord
  • Small Carrying Case
  • Printed Quick Start Guide
  • Safety and Compliance Sheets
  • DataView® Software
  • Two-Year Warranty

PEL 100 Series Relaunch

Click on a category to view a selection of compatible accessories with the AEMC PEL 103 Power/Energy Data Logger Kit with LCD.

AEMC 2136.80 Replacement USB Cable for the 8510 & C.A 6116, 10ft 2136.80
Replacement USB Cable for use with the AEMC DTR Models 8510 & C.A 6116.




AEMC 5000.45 Replacement USB SD Card Adapter for the AEMC PEL 102 and 103 5000.45
Replacement USB SD-Card Adapter for AEMC Power Energy Logger PEL 102 and PEL 103.




AEMC 5000.44 MultiFix Mounting System 5000.44
Universal Mounting System, for use with the AEMC 5212, 5215, 5217, 5231, & 5233. Replacement for PEL 102 & PEL 103.




AEMC 5000.43 Magnetized Voltage Probes, Colour Coded, Set of 2 5000.43
Set of 2, Red and Black Magnetized Voltage Probes. Rated 600V CAT IV, 1000V CAT III. For use with the AEMC 3945-B, 8220, 8230, 8335 and PEL Series.




AEMC MA193-10-BK MiniFlex Sensor, 100 mA to 3000 A, 10" MA193-10-BK
Compatible with all PowerPads and PEL 100 series of power quality analyzers, this sensor features a measurement range of 100 mA to 3000 A and a clamping diameter of 2.75" (70 mm).




AEMC SL261 AC/DC Current Probe, BNC, 100mV/A-10A Peak & 10mV/A-100A Peak SL261
This portable 100A peak current probe is insulated with a BNC output cable.




AEMC MR193-BK AC Current Probe for THE PowerPad and PEL Series MR193-BK
For use with AEMC 3945 PowerPad, 8220 & 8230 PowerPad Jr.




AEMC SR193-BK AC Current Probe, 1200 A SR193-BK
Designed for use with 3945/3945B/8220/8230/8333/8335/8336 power quality analyzers, PEL 102/103/105 power and energy loggers, and L104/L564 simple loggers II. Features a current range of 1200 A, and a clamping diameter of 2" (52 mm).




AEMC MN93-BK AC Current Probe, 200 A, 10' MN93-BK
Features 10' lead and 200 A capacity, this probe is designed for use with 3945/3945-B, 8220, 8230, 8333, 8335, 8336, PEL Series, L104, and L564.




AEMC MN193-BK Current Transformer for the L104, L564, PowerPad, and PEL Series MN193-BK
For use with AEMC Power Quality Instruments 8220, 8230, and 3945.




AEMC 193-36-BK AmpFlex Current Transformer, 6500A, 36" 193-36-BK
For use with the AEMC 3945/3945-B, 8220, 8230 & 8335. Features a 36" long cable.




AEMC 193-24-BK AmpFlex Current Transformer, 6500A, 24" 193-24-BK
Single 24" flexible sensor for use with the 3945/3945-B, this AmpFlex sensor model measures current, most typically in a conductor or bus bar, without opening the circuit. In addition, this insulated sensor protects users from dangerous voltages running through that circuit.




AEMC 2133.72 Small Classic Tool Bag, 13.0 x 9.8 x 9.5" 2133.72
Compact tool bag for field use by contractors, engineers, carpenters, plumbers, HVAC/R repairmen, maintenance personnel, architects, inspectors and other professionals.




AEMC 2140.40 BNC Adapter for the SL261 AC/DC Current Probe 2140.40
BNC Adapter for use with the SL261, 8220, 8333, 8335, and 8336 AC/DC Current Probes.




Ask a question about AEMC PEL 103 Power/Energy Data Logger Kit with LCD

Customer Reviews for the AEMC Instruments PEL 103

AEMC Instruments PEL 103 Offers

Energy costs can be calculated and displayed quickly and easily by simply inputting the unit cost for a kilowatt hour into the software. Data is stored on a removable SD card. Data can be retrieved using a USB, Bluetooth and/or Ethernet (local or internet) connection by transporting the SD card back to a PC. The comprehensive DataView®software (included) provides the ability to view data from several hundred PEL 100 series instruments on a local network or over the internet allowing the user to evaluate energy usage in a department or facility basis, a remote site, or even in a city, anywhere in the world. DataView®allows measurements to be viewed in real-time on a PC and stored data to be downloaded for analysis and report generation.

Features

  • Measurement of RMS voltages and currents at 128 times per cycle and stored every second
  • Measurement of VA, W and var power values (total and per phase) stored every second
  • Measurement of VAh, Wh and varh energy values (total and per phase) per second with source/load indication
  • Calculation of the cos φ Displacement Power Factor (DPF) and the Power Factor (PF) stored every second
  • Calculation of Total Harmonic Distortion (THD)
  • Measurement, calculation and display of the harmonics up to the 50th order for 50/60 Hz and 7th order for 400Hz
  • Measurement of the DC quantities (RMS calculation)
  • Display Measurements
  • Electrical network quantities are stored on a removable SD-Card
  • Automatic recognition of the connected current sensors
  • DataView software for configuration, data retrieval and real-time viewing of measurements with a PC
  • Compact and rugged case
  • Versatile communication interface choices built in (USB, Ethernet, Bluetooth)

Applications

  • Measure efficiency, find areas for potential savings
  • Track Sub-billing occupants for energy costs
  • Assign energy costs to departments or operations within a department
  • Track peak demand periods and find opportunities for surcharge reductions
  • Determine present capacity and circumvent unnecessary electrical expansion costs
  • Verify the reliability and operation of electrical machinery
  • Improve response time to solve power related problems
  • Track energy availability and reliability of supply
  • Reduce field service time at sub-stations

AEMC Instruments PEL 103 Specifications

General
Sampling Frequency 128 samples per cycle; 50/60Hz (16 samples/cycle 400Hz)
Data Storage Rate 1 per second
Demand Period Storage Rate User selectable (1, 2, 3, 4, 5, 6, 10, 12, 15, 20, 30 and 60 minutes)
Recorded Parameters (Single- and Poly-Phase) V, I, W, VA, var, PF, Tan, Wh, Vah, varh, THD (V and I)
Individual harmonics (from 1 through 50 per phase); Crest Factor (CF), Cos f/DPF
Event Log Tracks and records status changes and error messages along with recorded data
Front Panel Indicator LEDs Bluetooth active, recording in progress, phase connection reversal, overload, battery charging and SD Card status
Storage Capacity 2GB SD card (included) is used for storage. SD cards (up to 2GB); SDHC cards (4 to 32GB) formatted FAT32 are supported
Inputs Voltage: 3 voltage input channels via 4mm safety banana jacks
Current: 3 current input channels via custom 4 pin jacks that accept AEMC® probes and sensors
Mechanical
Communication Ports USB 2.0, Ethernet (RJ45), Wireless Bluetooth Class
Case and Index of Protection Double insulated, rubber over-molded, polycarbonate UL94 V1 rated
IP54 non operating
Mounting and Security Embedded magnets on back side, keyhole slot on back side
Kensington anti-theft system
Safety Rating and CE Rating Complies with IEC 61010-1:Ed3, and IEC 61010-2-030:Ed1 for 1000 V CAT III
600 V CAT IV, Pollution Degree 2, yes
Dimensions 10.08 x 4.92 x 1.46" (256 x 125 x 37mm)
Weight 2.2 lbs (1 kg)
Click here for complete specifications on the AEMC Instruments PEL 103

What's included with the AEMC Instruments PEL 103

  • Power and Energy Logger
  • 3 x Sensors
  • 4 x Black Test Leads
  • Alligator Clips
  • 12 x Color-Coded ID Markers
  • 8 GB SD-CArd with USB-SD-Card Reader
  • USB Drive
  • USB Cable
  • Power Cord
  • Small Carrying Case
  • Printed Quick Start Guide
  • Safety and Compliance Sheets
  • DataView® Software
  • Two-Year Warranty

PEL 100 Series Relaunch

Click on a category to view a selection of compatible accessories with the AEMC PEL 103 Power/Energy Data Logger Kit with LCD.

AEMC 2136.80 Replacement USB Cable for the 8510 & C.A 6116, 10ft 2136.80
Replacement USB Cable for use with the AEMC DTR Models 8510 & C.A 6116.




AEMC 5000.45 Replacement USB SD Card Adapter for the AEMC PEL 102 and 103 5000.45
Replacement USB SD-Card Adapter for AEMC Power Energy Logger PEL 102 and PEL 103.




AEMC 5000.44 MultiFix Mounting System 5000.44
Universal Mounting System, for use with the AEMC 5212, 5215, 5217, 5231, & 5233. Replacement for PEL 102 & PEL 103.




AEMC 5000.43 Magnetized Voltage Probes, Colour Coded, Set of 2 5000.43
Set of 2, Red and Black Magnetized Voltage Probes. Rated 600V CAT IV, 1000V CAT III. For use with the AEMC 3945-B, 8220, 8230, 8335 and PEL Series.




AEMC MA193-10-BK MiniFlex Sensor, 100 mA to 3000 A, 10" MA193-10-BK
Compatible with all PowerPads and PEL 100 series of power quality analyzers, this sensor features a measurement range of 100 mA to 3000 A and a clamping diameter of 2.75" (70 mm).




AEMC SL261 AC/DC Current Probe, BNC, 100mV/A-10A Peak & 10mV/A-100A Peak SL261
This portable 100A peak current probe is insulated with a BNC output cable.




AEMC MR193-BK AC Current Probe for THE PowerPad and PEL Series MR193-BK
For use with AEMC 3945 PowerPad, 8220 & 8230 PowerPad Jr.




AEMC SR193-BK AC Current Probe, 1200 A SR193-BK
Designed for use with 3945/3945B/8220/8230/8333/8335/8336 power quality analyzers, PEL 102/103/105 power and energy loggers, and L104/L564 simple loggers II. Features a current range of 1200 A, and a clamping diameter of 2" (52 mm).




AEMC MN93-BK AC Current Probe, 200 A, 10' MN93-BK
Features 10' lead and 200 A capacity, this probe is designed for use with 3945/3945-B, 8220, 8230, 8333, 8335, 8336, PEL Series, L104, and L564.




AEMC MN193-BK Current Transformer for the L104, L564, PowerPad, and PEL Series MN193-BK
For use with AEMC Power Quality Instruments 8220, 8230, and 3945.




AEMC 193-36-BK AmpFlex Current Transformer, 6500A, 36" 193-36-BK
For use with the AEMC 3945/3945-B, 8220, 8230 & 8335. Features a 36" long cable.




AEMC 193-24-BK AmpFlex Current Transformer, 6500A, 24" 193-24-BK
Single 24" flexible sensor for use with the 3945/3945-B, this AmpFlex sensor model measures current, most typically in a conductor or bus bar, without opening the circuit. In addition, this insulated sensor protects users from dangerous voltages running through that circuit.




AEMC 2133.72 Small Classic Tool Bag, 13.0 x 9.8 x 9.5" 2133.72
Compact tool bag for field use by contractors, engineers, carpenters, plumbers, HVAC/R repairmen, maintenance personnel, architects, inspectors and other professionals.




AEMC 2140.40 BNC Adapter for the SL261 AC/DC Current Probe 2140.40
BNC Adapter for use with the SL261, 8220, 8333, 8335, and 8336 AC/DC Current Probes.




Ask a question about AEMC PEL 103 Power/Energy Data Logger Kit with LCD

Customer Reviews for the AEMC Instruments PEL 103

More AEMC Instruments Products


Calibration Lab