AEMC L261 Simple Logger II AC/DC Voltage Data Logger, 600 V

Model: L261 | Order No: 2126.05 | UPC: 685338140361

AEMC L261 Simple Logger II AC/DC Voltage Data Logger, 600 V

Model: L261 | Order No: 2126.05 | UPC: 685338140361

One channel logger for voltage measuring, monitoring and troubleshooting. True RMS voltage recording up to 600V AC/DC. Stores up to 240,000 measurements.

One channel logger for voltage measuring, monitoring and troubleshooting. True RMS voltage recording up to 600V AC/DC. Stores up to 240,000 measurements.

Sale Price $493.05 USD
Regular Price $519.00 USD
Availability 2 in Stock
Quantity

Traceable In-House Calibration Certificate for your L261 Simple Logger II AC/DC Voltage Data Logger

Traceable In-House Calibration Certificate for your L261 Simple Logger II AC/DC Voltage Data Logger

AEMC L261 Offers

The AEMC L261 Simple Logger II is a one channel recording device powered by an alkaline battery pack. Line tracking is performed such that 64 samples over one line cycle are taken. Frequency tracking is performed over the range of ±2Hz around the nominal line frequency (50 or 60Hz). Harmonic measurements are calculated from these 64 samples (Harmonics are only available from the Simple Logger® II Control Panel within the DataView® software).

The Simple Logger® II records TRMS at a rate of up to eight times per second. The measurement process is performed no more than eight times per second. TRMS calculations are performed on a single line cycle. This means that the input(s) are ignored between measurement intervals.

The main advantage of the logger is its ability to perform a variety of recording tasks with easy and intuitive setup from a computer using DataView® software.

Analog information on the input is sampled and converted to a digital signal. This digital signal is processed and stored along with scale and time information. An optically isolated Universal Serial Bus (USB) port provides for the transfer of data from the instrument’s internal memory to the computer for analysis.

Features

  • TRMS voltage recording up to 600V AC/DC
  • 64 samples per cycle
  • Programmable storage rates from 8 every second to 1 every day
  • 4 user selectable storage modes
  • Stores up to 240,000 measurements in non-volatile memory
  • Powered by standard Alkaline batteries
  • Lightweight, compact, fits anywhere
  • 5 LED indicators quickly and clearly display logger status
  • Includes FREE DataView® software for data storage, real-time display, analysis and report generation
  • Isolated USB 2.0 communication cable included
  • EN 61010-1; 300V CAT IV; 600V CAT III

Applications

  • Surge and Sag recording
  • Long term supply monitoring
  • Industrial, commercial, residential monitoring
  • Monitor voltage harmonics
  • Find intermittent voltage problems
  • Machine monitoring

AEMC L261 Specifications

Channels One
Input Connection Two recessed 4mm safety banana jacks
Measurement Range 0 to 600V AC/DC
Resolution 0.1V
Accuracy (50/60Hz) 0 to 5V: unspecified
5 to 50V: ± (0.5% of Reading + 1V)
50 to 600V: ± (0.5% of Reading + 0.5V)
Input Impedance 40MΩ
Sample Rate 64 samples/cycle
Storage Rate Programmable from 8 every second to 1 every day
Storage Modes Start/Stop, FIFO, Extended Recording Mode (XRM™)* and Alarm
Recording Length 15 minutes to 8 weeks, programmable using DataView®
Memory 240,000 measurements (512KB)
Data is stored in non-volatile memory and retained if the battery is low or removed
Communication USB 2.0 optically isolated
Power Source 2 x 1.5V AA-cell Alkaline batteries (included)
Battery Life 100 hours to >45 days
(dependent on sample rate and recording length)
Click here for complete specifications on the AEMC Instruments L261

What's included with the AEMC L261

  • L261 Simple Logger II True RMS Datalogger
  • USB cable
  • DataView software
  • 2 x 1.5V AA-cell alkaline batteries
  • Set of leads
  • Set of alligator clips
  • Manual

Click on a category to view a selection of compatible accessories with the AEMC L261 Simple Logger II AC/DC Voltage Data Logger, 600 V.

AEMC 2118.49 Outlet Adapter with 4mm Banana Plugs, 110V 2118.49
For use with the AEMC L230, L260, L261, L481, L562, 8220, and 8230.




AEMC 2133.72 Small Classic Tool Bag, 13.0 x 9.8 x 9.5" 2133.72
Compact tool bag for field use by contractors, engineers, carpenters, plumbers, HVAC/R repairmen, maintenance personnel, architects, inspectors and other professionals.




AEMC 2140.63 Test Leads with Alligator Clips, Set of 2, Colour Coded, 10ft 2140.63
Set of 2, Color-coded 10ft (3m) with color-coded alligator clips (red/black). Rated 600V CAT IV, 15A. Replacement set for the AEMC 8220 and 8230.




AEMC 2126.49 Replacement USB Cable Type A to 5-pin Mini-B for Simple Logger II, DL-1080, and DL-1081 2126.49
Type A to 5-pin mini-B USB cable. For use with the AEMC Simple Logger II series and Models DL-1080 and DL-1081.




AEMC 2126.46 Type K Thermocouple Needle Probe for the SLII L642 & CA863, 7.25 x 0.5" 2126.46
K-Type Thermocouple Needle for use with the AEMC SLII L642 & CA863. 7.5x0.5", -58° to 1292°F.








Ask a question about AEMC L261 Simple Logger II AC/DC Voltage Data Logger, 600 V

Customer Reviews for the AEMC Instruments L261

AEMC L261 Offers

The AEMC L261 Simple Logger II is a one channel recording device powered by an alkaline battery pack. Line tracking is performed such that 64 samples over one line cycle are taken. Frequency tracking is performed over the range of ±2Hz around the nominal line frequency (50 or 60Hz). Harmonic measurements are calculated from these 64 samples (Harmonics are only available from the Simple Logger® II Control Panel within the DataView® software).

The Simple Logger® II records TRMS at a rate of up to eight times per second. The measurement process is performed no more than eight times per second. TRMS calculations are performed on a single line cycle. This means that the input(s) are ignored between measurement intervals.

The main advantage of the logger is its ability to perform a variety of recording tasks with easy and intuitive setup from a computer using DataView® software.

Analog information on the input is sampled and converted to a digital signal. This digital signal is processed and stored along with scale and time information. An optically isolated Universal Serial Bus (USB) port provides for the transfer of data from the instrument’s internal memory to the computer for analysis.

Features

  • TRMS voltage recording up to 600V AC/DC
  • 64 samples per cycle
  • Programmable storage rates from 8 every second to 1 every day
  • 4 user selectable storage modes
  • Stores up to 240,000 measurements in non-volatile memory
  • Powered by standard Alkaline batteries
  • Lightweight, compact, fits anywhere
  • 5 LED indicators quickly and clearly display logger status
  • Includes FREE DataView® software for data storage, real-time display, analysis and report generation
  • Isolated USB 2.0 communication cable included
  • EN 61010-1; 300V CAT IV; 600V CAT III

Applications

  • Surge and Sag recording
  • Long term supply monitoring
  • Industrial, commercial, residential monitoring
  • Monitor voltage harmonics
  • Find intermittent voltage problems
  • Machine monitoring

AEMC L261 Specifications

Channels One
Input Connection Two recessed 4mm safety banana jacks
Measurement Range 0 to 600V AC/DC
Resolution 0.1V
Accuracy (50/60Hz) 0 to 5V: unspecified
5 to 50V: ± (0.5% of Reading + 1V)
50 to 600V: ± (0.5% of Reading + 0.5V)
Input Impedance 40MΩ
Sample Rate 64 samples/cycle
Storage Rate Programmable from 8 every second to 1 every day
Storage Modes Start/Stop, FIFO, Extended Recording Mode (XRM™)* and Alarm
Recording Length 15 minutes to 8 weeks, programmable using DataView®
Memory 240,000 measurements (512KB)
Data is stored in non-volatile memory and retained if the battery is low or removed
Communication USB 2.0 optically isolated
Power Source 2 x 1.5V AA-cell Alkaline batteries (included)
Battery Life 100 hours to >45 days
(dependent on sample rate and recording length)
Click here for complete specifications on the AEMC Instruments L261

What's included with the AEMC L261

  • L261 Simple Logger II True RMS Datalogger
  • USB cable
  • DataView software
  • 2 x 1.5V AA-cell alkaline batteries
  • Set of leads
  • Set of alligator clips
  • Manual

Click on a category to view a selection of compatible accessories with the AEMC L261 Simple Logger II AC/DC Voltage Data Logger, 600 V.

AEMC 2118.49 Outlet Adapter with 4mm Banana Plugs, 110V 2118.49
For use with the AEMC L230, L260, L261, L481, L562, 8220, and 8230.




AEMC 2133.72 Small Classic Tool Bag, 13.0 x 9.8 x 9.5" 2133.72
Compact tool bag for field use by contractors, engineers, carpenters, plumbers, HVAC/R repairmen, maintenance personnel, architects, inspectors and other professionals.




AEMC 2140.63 Test Leads with Alligator Clips, Set of 2, Colour Coded, 10ft 2140.63
Set of 2, Color-coded 10ft (3m) with color-coded alligator clips (red/black). Rated 600V CAT IV, 15A. Replacement set for the AEMC 8220 and 8230.




AEMC 2126.49 Replacement USB Cable Type A to 5-pin Mini-B for Simple Logger II, DL-1080, and DL-1081 2126.49
Type A to 5-pin mini-B USB cable. For use with the AEMC Simple Logger II series and Models DL-1080 and DL-1081.




AEMC 2126.46 Type K Thermocouple Needle Probe for the SLII L642 & CA863, 7.25 x 0.5" 2126.46
K-Type Thermocouple Needle for use with the AEMC SLII L642 & CA863. 7.5x0.5", -58° to 1292°F.








Ask a question about AEMC L261 Simple Logger II AC/DC Voltage Data Logger, 600 V

Customer Reviews for the AEMC Instruments L261

More AEMC Instruments Products