Measures voltage, current via clamp, power, waveforms, and harmonics.
Measures voltage, current via clamp, power, waveforms, and harmonics.
Features
Continuity/Resistance | |
I Rated/Range/Resolution | I > 200 mA / 39.99 Ω / 0.01 Ω / ±(1.5% of measurement + 2cts) 12 mA / 39.99 Ω & 399.9 Ω / 0.01 & 0.1 Ω / ±(1.5% of measurement + 5cts) with beep |
Range/Resolution/Accuracy | 4 kΩ / 1 Ω /±(1.5% of measurement + 5cts) 40 to 400 kΩ / 10 to 100 Ω / ±(1.5% of measurement + 2cts) |
Insulation | |
Rated Voltage | 50/100/250/500/1000 V DC |
Range/Resolution/Accuracy | 0.01 MΩ to 2 GΩ / 10 kΩ to 1 MΩ / ±(5% of measurement + 3cts) |
Short-Circuit Current | ≤3 mA |
Ground Resistance | |
3-Point Range/Resolution/Accuracy | 0.50 to 40 Ω / 0.01 Ω / ±(2% of measurement + 10cts) 40 Ω to 15 kΩ / 0.1 to 1 Ω / ±(2% of measurement + 2cts) 15 to 40 k Ω / 10 Ω / ±(10% of measurement + 2cts) |
3-Point Ufk | Complies with SEV 3569 |
1-Point Selective Range/Resolution/Accuracy | 0.20 to 39.99 Ω – 40 to 399.9 Ω / 0.01 to 0.1 Ω / ±(10% of measurement + 10cts) (ISel via clamp) |
Loop Impedance (ZS (L-PE) & ZI (L-N OR L-L))/1-Point Live Ground | |
Live Ground Installation Voltage/Frequency | 90 to 500 V / 15.8 to 17.5 Hz – 45 to 65 Hz |
High-Current Mode Range/Resolution/Accuracy | Max. Test Current: 7.5 A (0.050) 0.100 to 0.5 Ω / 0.001 Ω / ±(10% of measurement + 20cts) 0.5 to 3.999 Ω / 0.001 Ω / ±(5% of measurement + 20cts) 3.999 to 39.99 Ω / 0.01 Ω / ±(5% of measurement + 2cts) 39.99 to 399.99 Ω / 0.1 Ω / ±(5% of measurement + 2cts) |
Continuity/Resistance | |
I Rated/Range/Resolution | I > 200 mA / 39.99 Ω / 0.01 Ω / ±(1.5% of measurement + 2cts) 12 mA / 39.99 Ω & 399.9 Ω / 0.01 & 0.1 Ω / ±(1.5% of measurement + 5cts) with beep |
Range/Resolution/Accuracy | 4 kΩ / 1 Ω /±(1.5% of measurement + 5cts) 40 to 400 kΩ / 10 to 100 Ω / ±(1.5% of measurement + 2cts) |
Insulation | |
Rated Voltage | 50/100/250/500/1000 V DC |
Range/Resolution/Accuracy | 0.01 MΩ to 2 GΩ / 10 kΩ to 1 MΩ / ±(5% of measurement + 3cts) |
Short-Circuit Current | ≤3 mA |
Ground Resistance | |
3-Point Range/Resolution/Accuracy | 0.50 to 40 Ω / 0.01 Ω / ±(2% of measurement + 10cts) 40 Ω to 15 kΩ / 0.1 to 1 Ω / ±(2% of measurement + 2cts) 15 to 40 k Ω / 10 Ω / ±(10% of measurement + 2cts) |
3-Point Ufk | Complies with SEV 3569 |
1-Point Selective Range/Resolution/Accuracy | 0.20 to 39.99 Ω – 40 to 399.9 Ω / 0.01 to 0.1 Ω / ±(10% of measurement + 10cts) (ISel via clamp) |
Loop Impedance (ZS (L-PE) & ZI (L-N OR L-L))/1-Point Live Ground | |
Live Ground Installation Voltage/Frequency | 90 to 500 V / 15.8 to 17.5 Hz – 45 to 65 Hz |
High-Current Mode Range/Resolution/Accuracy | Max. Test Current: 7.5 A (0.050) 0.100 to 0.5 Ω / 0.001 Ω / ±(10% of measurement + 20cts) 0.5 to 3.999 Ω / 0.001 Ω / ±(5% of measurement + 20cts) 3.999 to 39.99 Ω / 0.01 Ω / ±(5% of measurement + 2cts) 39.99 to 399.99 Ω / 0.1 Ω / ±(5% of measurement + 2cts) |