AEMC 607 Power Clamp Meter/Data Logger, 1000 V AC/DC, 2000 A AC/3000 A DC

Model: 607 | Order No: 2139.61 | UPC: 685338220445

AEMC 607 Power Clamp Meter/Data Logger, 1000 V AC/DC, 2000 A AC/3000 A DC

Model: 607 | Order No: 2139.61 | UPC: 685338220445

This power clamp meter measures power parameters of single- and three-phase systems, including in rush current and frequency. Records up to 1000 measurements and is enabled with wireless Bluetooth communication.

This power clamp meter measures power parameters of single- and three-phase systems, including in rush current and frequency. Records up to 1000 measurements and is enabled with wireless Bluetooth communication.

Sale Price $636.50 USD
Regular Price $670.00 USD
Availability 7 to 8 Weeks
Quantity

Traceable In-House Calibration Certificate for your 607 Power Clamp Meter/Data Logger

Traceable In-House Calibration Certificate for your 607 Power Clamp Meter/Data Logger

Recommended Accessories

AEMC 2139.73 Carrying Case-

AEMC 607 Offers

The AEMC 607 TRMS Clamp-On Meter provides a new standard for safety and measurement capability not available in any other clamp meter sold today. It's ergonomically designed and easily used by one hand, including function selection and button pushing even with a glove on. In addition to the standard measurement of volts, amps, frequency, resistance, diode checking and continuity, the AEMC 607 offers several unequaled functions.

True InRush®
Unlike other instruments which only measure the InRush when the installation is first powered up, the AEMC 607 measures all types of InRush, even those due to load increases on and installation which is already up and running. This is an exclusive AEMC feature. Both peak and RMS InRush values are captured at a 1ms sample rate and 100ms duration windows.

Power Measurements are available for Watts, VARs, and VA, including Min and Max tracking. The AEMC 607 also has the capability to display single- and three-phase power measurements. Total Harmonic Distortion both total and referenced to the fundamental are also available taking in harmonic frequencies to the 25th order.

Harmonic Analysis on individual harmonics is available up to the 25th harmonic of either 50 or 60Hz fundamental and up to the 7th harmonic on a 400Hz fundamental.

Data Logging is a standard feature on the AEMC 607. Up to 1000 measurements can be stored from any of the function positions. Max, Min and present values are stored each time. Storage rate is programmable from 1 per second to 1 every 600 seconds. Communication to the PC is wireless via Bluetooth. Graphing analysis of the data is accomplished by a comprehensive software package called DataView®.

Other functions include Power Factor, Min/Max monitoring of measurement from any function position and peak +/- display is available. A hold function is provided to retain the last reading on any of the functions. A truly unique meter focused on user safety as well as measurement performance.

Features

  • 1000V CAT IV Rated
  • UL 94 flame retardant self-extinguishing
  • IP54 Rated
  • 10,000-count blue electroluminescent backlit display
  • Measures up to 1000V AC (1400V peak), 1000V DC and AC+DC with resolution to 10mV
  • Measures up to 1000A AC and 2000A DC
  • Measures single- and three-phase power (real, reactive and apparent) up to 3MW with resolution to 1W
  • Measures frequency to 20kHz with 0.1Hz resolution
  • Auto selects AC or DC measurement voltage
  • True InRush current measurement with 1mS capture
  • Records up to 1000 measurements
  • Wireless Bluetooth communications
  • Jaw opening up to 1.89"
  • Leads are constructed with a flexible silicone material

Applications

  • General purpose electrical troubleshooting
  • Motor start up analysis
  • Voltage troubleshooting
  • Bond and continuity checking
  • Phase sequence checking
  • Harmonic analysis
  • Power monitoring
  • Aircraft and ship board troubleshooting

AEMC 607 Specifications

Current AC (rms) 2000A
Current DC 3000A
Current AC+DC 3000A Peak
Voltage AC (rms) 1000V
Voltage DC 1000V
Voltage AC+DC 1000V
Ohms 100kΩ
Continuity (Buzzer) Yes (< 40Ω)
Voltage Frequency (Hz) 20kHz
Current Frequency (Hz) 1kHz
Records 1000
Jaw Opening Size (Diameter) 2.36"
Protection Index Housing: IP54 (per standard IEC-60529)
Jaws: IP40
Click here for complete specifications on the AEMC Instruments 607

What's included with the AEMC 607

  • True RMS Power Clamp-on Meter with Phase Rotation
  • Set of two color coded silicone insulated test leads
  • Test probes and alligator clips
  • Hard carrying case
  • Four AA Batteries
  • Safety Information sheet
  • DataView Software
  • Bluetooth adapter

Click on a category to view a selection of compatible accessories with the AEMC 607 Power Clamp Meter/Data Logger, 1000 V AC/DC, 2000 A AC/3000 A DC.

AEMC 2139.73 Carrying Case 2139.73
Replacement Carrying Case for use with Clamp-on Meter Models 407 & 608




Ask a question about AEMC 607 Power Clamp Meter/Data Logger, 1000 V AC/DC, 2000 A AC/3000 A DC

Customer Reviews for the AEMC Instruments 607

AEMC 607 Offers

The AEMC 607 TRMS Clamp-On Meter provides a new standard for safety and measurement capability not available in any other clamp meter sold today. It's ergonomically designed and easily used by one hand, including function selection and button pushing even with a glove on. In addition to the standard measurement of volts, amps, frequency, resistance, diode checking and continuity, the AEMC 607 offers several unequaled functions.

True InRush®
Unlike other instruments which only measure the InRush when the installation is first powered up, the AEMC 607 measures all types of InRush, even those due to load increases on and installation which is already up and running. This is an exclusive AEMC feature. Both peak and RMS InRush values are captured at a 1ms sample rate and 100ms duration windows.

Power Measurements are available for Watts, VARs, and VA, including Min and Max tracking. The AEMC 607 also has the capability to display single- and three-phase power measurements. Total Harmonic Distortion both total and referenced to the fundamental are also available taking in harmonic frequencies to the 25th order.

Harmonic Analysis on individual harmonics is available up to the 25th harmonic of either 50 or 60Hz fundamental and up to the 7th harmonic on a 400Hz fundamental.

Data Logging is a standard feature on the AEMC 607. Up to 1000 measurements can be stored from any of the function positions. Max, Min and present values are stored each time. Storage rate is programmable from 1 per second to 1 every 600 seconds. Communication to the PC is wireless via Bluetooth. Graphing analysis of the data is accomplished by a comprehensive software package called DataView®.

Other functions include Power Factor, Min/Max monitoring of measurement from any function position and peak +/- display is available. A hold function is provided to retain the last reading on any of the functions. A truly unique meter focused on user safety as well as measurement performance.

Features

  • 1000V CAT IV Rated
  • UL 94 flame retardant self-extinguishing
  • IP54 Rated
  • 10,000-count blue electroluminescent backlit display
  • Measures up to 1000V AC (1400V peak), 1000V DC and AC+DC with resolution to 10mV
  • Measures up to 1000A AC and 2000A DC
  • Measures single- and three-phase power (real, reactive and apparent) up to 3MW with resolution to 1W
  • Measures frequency to 20kHz with 0.1Hz resolution
  • Auto selects AC or DC measurement voltage
  • True InRush current measurement with 1mS capture
  • Records up to 1000 measurements
  • Wireless Bluetooth communications
  • Jaw opening up to 1.89"
  • Leads are constructed with a flexible silicone material

Applications

  • General purpose electrical troubleshooting
  • Motor start up analysis
  • Voltage troubleshooting
  • Bond and continuity checking
  • Phase sequence checking
  • Harmonic analysis
  • Power monitoring
  • Aircraft and ship board troubleshooting

AEMC 607 Specifications

Current AC (rms) 2000A
Current DC 3000A
Current AC+DC 3000A Peak
Voltage AC (rms) 1000V
Voltage DC 1000V
Voltage AC+DC 1000V
Ohms 100kΩ
Continuity (Buzzer) Yes (< 40Ω)
Voltage Frequency (Hz) 20kHz
Current Frequency (Hz) 1kHz
Records 1000
Jaw Opening Size (Diameter) 2.36"
Protection Index Housing: IP54 (per standard IEC-60529)
Jaws: IP40
Click here for complete specifications on the AEMC Instruments 607

What's included with the AEMC 607

  • True RMS Power Clamp-on Meter with Phase Rotation
  • Set of two color coded silicone insulated test leads
  • Test probes and alligator clips
  • Hard carrying case
  • Four AA Batteries
  • Safety Information sheet
  • DataView Software
  • Bluetooth adapter

Click on a category to view a selection of compatible accessories with the AEMC 607 Power Clamp Meter/Data Logger, 1000 V AC/DC, 2000 A AC/3000 A DC.

AEMC 2139.73 Carrying Case 2139.73
Replacement Carrying Case for use with Clamp-on Meter Models 407 & 608




Ask a question about AEMC 607 Power Clamp Meter/Data Logger, 1000 V AC/DC, 2000 A AC/3000 A DC

Customer Reviews for the AEMC Instruments 607

More AEMC Instruments Products

Calibration Lab