ACR 01-0010 SmartReader Plus

Model: ACR 01-0010 | Order No: 01-0010

ACR 01-0010 SmartReader Plus

Model: ACR 01-0010 | Order No: 01-0010

SmartReader Plus 32KB, 4 channel temperature data logger. Capable of storing up to 21,500 measurements.

SmartReader Plus 32KB, 4 channel temperature data logger. Capable of storing up to 21,500 measurements.

Discontinued!

This product has been discontinued and is no longer available.
This is the direct replacement:

ACR 01-0014 SmartReader Plus 7 Data Logger-

ACR 01-0014 SmartReader Plus 7 Data Logger

Model: ACR 01-0014 | Order No: 01-0014

Designed for easy recording of common process signal variables. Additionally, this smartreader data logger is ideal for monitoring a wide variety of measurement parameters.


SmartReader Plus 3, 32KB, Eight Channel Data Logger

The SmartReader Plus 3 easily and accurately records AC Current and Voltage (requires separate transducer). Simply connect the logger to ACR's current probes which are then clamped around the conductors, wire the voltage transducer option and begin recording. From this data, total energy consumption (kWh) can be determined for a given period using TrendReader software.


Features:

  • Eight channels
  • Monitor current and voltage (single or 3-phase)
  • Determine energy consumption

Applications:

  • Energy Usage Profile - Real Power (kW)
  • Power Consumption Monitor - Energy Delivered (kWh)
  • Electrical Load Study - Apparent Power (kVA)
  • 2 or 3 Phase Balancing - Amperage (A)

Specifications:

GENERAL SPECIFICATIONS
Catalog Number (SRP-003) 01-0010
Catalog Number (SRP-003-128K) 01-0114
Catalog Number (SRP-003-1.5M) 01-0143
Size 107mm x 74mm x 22mm (4.2" x 2.9" x 0.9")
Weight 110 g (3.75 oz)
Case Material Noryl® Plastic
Battery 3.6 volt Lithium, 1 Amp-Hour
Resolution 12-bit (1 part in 4096)
Mounting Magnetic backing or locking eyelet
Clock Accuracy ± 2 seconds per day
Sampling Methods Continuous (First-in First-out), Stop When Full (Fill-then-stop)
*Not available with sample rates faster than eight seconds.
Operating Limits -40°C to 70°C (-40°F to 158°F) and 0 to 95% RH (non-condensing)
PC Requirements Windows PC with at least one free USB or serial port (depending on interface)
Software Requirements TrendReader® 2 (Compatible with Windows 2000 SP4, XP SP1 and Vista 32 bit)
Memory Size
(3 models available)
128 KB (capable of storing up to 87,000 readings
1.5MB (capable of storing up to 1,048,000 readings)
Sampling Rates User selectable rates from 25 per second to once every eight hours
(BP-101 battery pack or PS-201 power supply required for sampling rates faster than eight seconds)
Number of Channels Eight (8):
  • One (1) for internal temperature
  • Four (4) for AC current
  • Three (3) 0-5V DC inputs for use with ACR's voltage transducer to monitor 3-phase voltage
SENSOR SPECIFICATIONS
Internal Temperature Sensor
Type NTC Thermistor - 10,000 Ohm @ 25°C (77°F)
Range -40°C to 70°C (-40°F to 158°F)
Accuracy ±0.2°C over the range of 0°C to 70°C (± 0.3°F over the range of 32°F to 158°F)
Resolution 0.03°C (0.05°F) @ 25°C; better than 0.07°C (0.12°F) between -25°C and 70°C
(-13°F and 158°F); better than 0.13°C (0.23°F) between -40°C and -25°C
(-40°F and -13°F)
Current Sensors Range Catalog Number
A60FL (60 Hz) 5, 25, 100, 250 Amps 35-0004
A65FL (50 Hz) 5, 25, 100, 250 Amps 35-0006
A70FL (60 Hz) 10, 50, 250, 500 Amps 35-0005
A75FL (50 Hz) 10, 50, 250, 500 Amps 35-0007
Nominal Voltage Ranges Accuracy
120V (1 phase, 60 Hz) Current channels: ±3.0% of full scale above 10% of range
480V 3 phase, 60Hz) Voltage channels: ±0.5% of full scale
Click here for complete specifications on the ACR ACR 01-0010

What's included with the ACR ACR 01-0010

  • ACR 01-0010 SmartReader Plus

Click on a category to view a selection of compatible accessories with the ACR 01-0010 SmartReader Plus.

ACR Fast Sampling Battery Pack BP-101 ACR 01-0078
Portable power supply for SmartReader Plus data loggers to allow them to sample faster than 8 seconds.




ACR 29-0013 Terminal Block Strain Relief ACR 29-0013
Strain relief for sensors attached to SmartReader/SmartReader Plus 11-pin terminal blocks.




ACR 01-0171 SmartReader Plus Display Module ACR 01-0171
Portable Real-time Display Module for any SmartReader Plus Data Logger (2 AA batteries and 1 foot cable included).




ACR 01-0098 Network Y Splitter - Stereo (YA-200) ACR 01-0098
Allows a SmartReader Plus logger to be added to an ACR-stereo type network. 1 male and 2 female ends. Includes 1ft male to male adapter cable.




ACR 01-0167 Alarm Module - 100 - NA ACR 01-0167
Alarm module, stereo Y-adapter, 1ft male-male stereo cable, and 120V NA power supply for SmartReader Plus loggers.




ACR 01-0168 Alarm Module - 100 - EU ACR 01-0168
Alarm module, stereo Y-adapter, 1ft male-male stereo cable, and 240V Cont. Europe power supply for SmartReader Plus loggers.




ACR 35-0000 Therm Penetration Probe - Low Temp ACR 35-0000
Stainless steel, 3 1/2in penetration probe w/handle. Thermistor type. Range: -60 to 55°C (-75 to 130°F). Length: 10ft (3 meters).




ACR 35-0001 Thermal Probe - General Purpose Temperature ACR 35-0001
Stainless Steel, 1 X 3/16in probe. Thermistor type. Range: -35 to 95°C (-30 to 200°F). Length: 20ft (6 meters).




ACR 35-0002 Therm-Probe - GP Tip - 80C - SR SRP ACR 35-0002
Stainless Steel, 1 X 3/16in probe. Thermistor type. Range: 10 to 170°C (50 to 335°F). Length: 20ft (6 meters).




ACR 35-0003 Thermal Probe - Oven Temperature ACR 35-0003
Stainless steel, 1 X 3/16in probe. Thermistor type. Range: 70 to 255°C (155 to 490°F). Length: 20ft (6 meters).




ACR 35-0020 Skin Surface Thermal Probe - Human Temperature ACR 35-0020
Stainless steel, 1/3 X 9/64in probe. Thermistor type. Range: 20 to 40°C (68 to 104°F). Length: 5ft (1.5 meters).




ACR 35-0025 Pipe Surface Thermal Probe - General Purpose ACR 35-0025
Stainless steel, 1 X 3/16in probe. Thermistor type. Range: -35 to 95°C (-30 to 200°F). Length: 20ft (6 meters).




ACR 01-0165 Net Fast Sample Power Supply - 120V N A ACR 01-0165
120V AC to 5V DC power supply for SmartReader Plus networks with a minimum of three loggers or >50ft of network cable. Includes inYin splitter (YA-200).




ACR 01-0057 Weatherproof Logger Box ACR 01-0057
NEMA 4X clear-faced weatherproof box for all ACR loggers, Size: 18 x 13 x 10cm (7 x 5 x 4").




ACR Systems SC-100 General Purpose Logger Storage Case ACR 01-0106
General Purpose Logger Storage Case, Briefcase style, locking, customizable logger and accessory storage case.




ACR 01-0077 Logger-PC Interface Cable (IC-101) ACR 01-0077
9-pin PC serial port to logger interface cable. Compatible with SmartReader and SmartReader Plus loggers.




ACR 01-0088 Logger-PC Interface Cable, 4' ACR 01-0088
Connect the SmartReader Plus data logger to PC computer through a USB port with this interface cable which measures 4' (1.22 m). In addition, this interface cable has a 0.138" (3.5 mm) stereo jack connection.




ACR 29-0004 Terminal Block - 11 Pin ACR 29-0004
11-pin female teminal block for SmartReader/SmartReader Plus sensor inputs.




Ask a question about ACR 01-0010 SmartReader Plus

Customer Reviews for the ACR ACR 01-0010

SmartReader Plus 3, 32KB, Eight Channel Data Logger

The SmartReader Plus 3 easily and accurately records AC Current and Voltage (requires separate transducer). Simply connect the logger to ACR's current probes which are then clamped around the conductors, wire the voltage transducer option and begin recording. From this data, total energy consumption (kWh) can be determined for a given period using TrendReader software.


Features:

  • Eight channels
  • Monitor current and voltage (single or 3-phase)
  • Determine energy consumption

Applications:

  • Energy Usage Profile - Real Power (kW)
  • Power Consumption Monitor - Energy Delivered (kWh)
  • Electrical Load Study - Apparent Power (kVA)
  • 2 or 3 Phase Balancing - Amperage (A)

Specifications:

GENERAL SPECIFICATIONS
Catalog Number (SRP-003) 01-0010
Catalog Number (SRP-003-128K) 01-0114
Catalog Number (SRP-003-1.5M) 01-0143
Size 107mm x 74mm x 22mm (4.2" x 2.9" x 0.9")
Weight 110 g (3.75 oz)
Case Material Noryl® Plastic
Battery 3.6 volt Lithium, 1 Amp-Hour
Resolution 12-bit (1 part in 4096)
Mounting Magnetic backing or locking eyelet
Clock Accuracy ± 2 seconds per day
Sampling Methods Continuous (First-in First-out), Stop When Full (Fill-then-stop)
*Not available with sample rates faster than eight seconds.
Operating Limits -40°C to 70°C (-40°F to 158°F) and 0 to 95% RH (non-condensing)
PC Requirements Windows PC with at least one free USB or serial port (depending on interface)
Software Requirements TrendReader® 2 (Compatible with Windows 2000 SP4, XP SP1 and Vista 32 bit)
Memory Size
(3 models available)
128 KB (capable of storing up to 87,000 readings
1.5MB (capable of storing up to 1,048,000 readings)
Sampling Rates User selectable rates from 25 per second to once every eight hours
(BP-101 battery pack or PS-201 power supply required for sampling rates faster than eight seconds)
Number of Channels Eight (8):
  • One (1) for internal temperature
  • Four (4) for AC current
  • Three (3) 0-5V DC inputs for use with ACR's voltage transducer to monitor 3-phase voltage
SENSOR SPECIFICATIONS
Internal Temperature Sensor
Type NTC Thermistor - 10,000 Ohm @ 25°C (77°F)
Range -40°C to 70°C (-40°F to 158°F)
Accuracy ±0.2°C over the range of 0°C to 70°C (± 0.3°F over the range of 32°F to 158°F)
Resolution 0.03°C (0.05°F) @ 25°C; better than 0.07°C (0.12°F) between -25°C and 70°C
(-13°F and 158°F); better than 0.13°C (0.23°F) between -40°C and -25°C
(-40°F and -13°F)
Current Sensors Range Catalog Number
A60FL (60 Hz) 5, 25, 100, 250 Amps 35-0004
A65FL (50 Hz) 5, 25, 100, 250 Amps 35-0006
A70FL (60 Hz) 10, 50, 250, 500 Amps 35-0005
A75FL (50 Hz) 10, 50, 250, 500 Amps 35-0007
Nominal Voltage Ranges Accuracy
120V (1 phase, 60 Hz) Current channels: ±3.0% of full scale above 10% of range
480V 3 phase, 60Hz) Voltage channels: ±0.5% of full scale
Click here for complete specifications on the ACR ACR 01-0010

What's included with the ACR ACR 01-0010

  • ACR 01-0010 SmartReader Plus

Click on a category to view a selection of compatible accessories with the ACR 01-0010 SmartReader Plus.

ACR Fast Sampling Battery Pack BP-101 ACR 01-0078
Portable power supply for SmartReader Plus data loggers to allow them to sample faster than 8 seconds.




ACR 29-0013 Terminal Block Strain Relief ACR 29-0013
Strain relief for sensors attached to SmartReader/SmartReader Plus 11-pin terminal blocks.




ACR 01-0171 SmartReader Plus Display Module ACR 01-0171
Portable Real-time Display Module for any SmartReader Plus Data Logger (2 AA batteries and 1 foot cable included).




ACR 01-0098 Network Y Splitter - Stereo (YA-200) ACR 01-0098
Allows a SmartReader Plus logger to be added to an ACR-stereo type network. 1 male and 2 female ends. Includes 1ft male to male adapter cable.




ACR 01-0167 Alarm Module - 100 - NA ACR 01-0167
Alarm module, stereo Y-adapter, 1ft male-male stereo cable, and 120V NA power supply for SmartReader Plus loggers.




ACR 01-0168 Alarm Module - 100 - EU ACR 01-0168
Alarm module, stereo Y-adapter, 1ft male-male stereo cable, and 240V Cont. Europe power supply for SmartReader Plus loggers.




ACR 35-0000 Therm Penetration Probe - Low Temp ACR 35-0000
Stainless steel, 3 1/2in penetration probe w/handle. Thermistor type. Range: -60 to 55°C (-75 to 130°F). Length: 10ft (3 meters).




ACR 35-0001 Thermal Probe - General Purpose Temperature ACR 35-0001
Stainless Steel, 1 X 3/16in probe. Thermistor type. Range: -35 to 95°C (-30 to 200°F). Length: 20ft (6 meters).




ACR 35-0002 Therm-Probe - GP Tip - 80C - SR SRP ACR 35-0002
Stainless Steel, 1 X 3/16in probe. Thermistor type. Range: 10 to 170°C (50 to 335°F). Length: 20ft (6 meters).




ACR 35-0003 Thermal Probe - Oven Temperature ACR 35-0003
Stainless steel, 1 X 3/16in probe. Thermistor type. Range: 70 to 255°C (155 to 490°F). Length: 20ft (6 meters).




ACR 35-0020 Skin Surface Thermal Probe - Human Temperature ACR 35-0020
Stainless steel, 1/3 X 9/64in probe. Thermistor type. Range: 20 to 40°C (68 to 104°F). Length: 5ft (1.5 meters).




ACR 35-0025 Pipe Surface Thermal Probe - General Purpose ACR 35-0025
Stainless steel, 1 X 3/16in probe. Thermistor type. Range: -35 to 95°C (-30 to 200°F). Length: 20ft (6 meters).




ACR 01-0165 Net Fast Sample Power Supply - 120V N A ACR 01-0165
120V AC to 5V DC power supply for SmartReader Plus networks with a minimum of three loggers or >50ft of network cable. Includes inYin splitter (YA-200).




ACR 01-0057 Weatherproof Logger Box ACR 01-0057
NEMA 4X clear-faced weatherproof box for all ACR loggers, Size: 18 x 13 x 10cm (7 x 5 x 4").




ACR Systems SC-100 General Purpose Logger Storage Case ACR 01-0106
General Purpose Logger Storage Case, Briefcase style, locking, customizable logger and accessory storage case.




ACR 01-0077 Logger-PC Interface Cable (IC-101) ACR 01-0077
9-pin PC serial port to logger interface cable. Compatible with SmartReader and SmartReader Plus loggers.




ACR 01-0088 Logger-PC Interface Cable, 4' ACR 01-0088
Connect the SmartReader Plus data logger to PC computer through a USB port with this interface cable which measures 4' (1.22 m). In addition, this interface cable has a 0.138" (3.5 mm) stereo jack connection.




ACR 29-0004 Terminal Block - 11 Pin ACR 29-0004
11-pin female teminal block for SmartReader/SmartReader Plus sensor inputs.




Ask a question about ACR 01-0010 SmartReader Plus

Customer Reviews for the ACR ACR 01-0010

More ACR Products

Calibration Lab