AALBORG GFC17A-VAL6-A0-3NC-07-SS Mass Flow Controller, 0 to 1 LPM N2, 1/4"

Model: GFC17A-VAL6-A0-3NC-07-SS | Order No: GFCS-011984

AALBORG GFC17A-VAL6-A0-3NC-07-SS Mass Flow Controller, 0 to 1 LPM N2, 1/4"

Model: GFC17A-VAL6-A0-3NC-07-SS | Order No: GFCS-011984

Mass flow controllers designed to indicate and control flow rates of gases. Advanced straight tube sensor combined with flow passage elements constructed of aluminum and brass for non-corrosive gases. Features a Max Pressure Differential of 50 psi (3.4 bar).

Mass flow controllers designed to indicate and control flow rates of gases. Advanced straight tube sensor combined with flow passage elements constructed of aluminum and brass for non-corrosive gases. Features a Max Pressure Differential of 50 psi (3.4 bar).

Your Price $1412.00 USD
Availability 1 to 2 Weeks
Quantity

AALBORG GFC17A-VADL2-E0-07-N2 Mass Flow Controller Offers

Features

  • Zero and span adjustments are accessible from the outside of transmitters
  • Metered gases are divided into two laminar flow paths, one through the primary flow conduit, and the other through a capillary sensor tube
  • Both conduits are designed to ensure laminar flows and there-fore the ratio of their flow rates is constant
  • Two precision temperature sensing windings on the sensor tube are heated, and when flow takes place, gas carries heat from the upstream to the downstream windings
  • Resultant temperature differential is proportional to the change in resistance of the sensor windings
  • Wheatstone bridge design is used to monitor the temperature dependent resistance gradient on the sensor windings which is nearly proportional to the instantaneous rate of flow
  • Output signals of 0 to 5Vdc and 4 to 20mA are generated indicating mass molecular based flow rates of the metered gas
  • The combined gas streams flow through a proportionating electromagnetic valve with an appropriately selected orifice
  • The closed loop control circuit continuously monitors the mass flow
  • output and maintains it at the set flow rate
  • Flow setpoints are controlled either locally or remotely
  • LCD readout built into the top of the transmitters is tilt-able over 90° to provide optimal reading comfort
  • LCD readout is connected to the transducer by a standard modular plug, and is readily removable for remote reading installations
  • Transducers without LCD readout are also available
  • Available with flow ranges from 10 sccm to 1000 l/min
  • Gases are connected by means of 1/4", 3/8" or optional 1/8" compression fittings and 3/4" FNPT fittings
  • Transducer power supply ports are fuse and polarity protected

AALBORG GFC17A-VADL2-E0-07-N2 Specifications

Accuracy ±1.5% f.s. incl. linearity for gas temperatures of 59 to 77°F (15 to 25°C)
Pressures of 5 to 60 psia (0.4 to 4.1 bar)
Repeatability ±0.5% f.s.
Response Time Generally 2s to within ±2% of actual flow rate over 25 to 100% f.s.
Temp. Coefficient 0.15% f.s./°C
Pressure Coefficient 0.01% f.s./psi (0.07 bar)
Optimum Gas Press. 25 psig (1.73 bar)
Max. Gas Pressure 1000 psig (70 bar)
Max. Pressure Diff. GFC17, GFC37: 50 psi (3.4 bar)
GFC47: 40 psi (2.7 bar)
Gas Temperature 41 to 122°F (5 to 50°C)
Leak Integrity 1 x 10-7 ml/sec of helium maximum to the outside environment
Materials Fluid Contact Anodized aluminum, 316 stainless steel, brass & Viton O-rings 
Attitude Sensitivity No greater than ±15° rotation from horizontal to vertical
Output Signals Linear 0-5 Vdc (1000Ω min. load impedance); 4-20 mA (0-500Ω loop resistance); max. noise ±20mV
Command Signals Analog 0-5 Vdc or 4-20 mA for remote set point mode; NPN compatible purge/valve off
Input Power +12 Vdc, 800mA; +24 Vdc, 650mA option
Connections GFC17 & 37: 1/4" compression fittings
GFC47: 3/8" compression fittings
GFC67: 1/2" compression fittings 
Display 3-1/2 digit LCD, 0.5" high characters
Click here for complete specifications on the AALBORG GFC17A-VAL6-A0-3NC-07-SS

What's included with the AALBORG GFC17A-VAL6-A0-3NC-07-SS

  • AALBORG GFC17A-VAL6-A0-3NC-07-SS Mass Flow Controller, 0 to 1 LPM N2, 1/4"

Click on a category to view a selection of compatible accessories with the AALBORG GFC17A-VAL6-A0-3NC-07-SS Mass Flow Controller, 0 to 1 LPM N2, 1/4".

AALBORG PS-GFC-110NA-2 Power Supply for AALBORG Mass Flow Controllers PS-GFC-110NA-2
This US plug is has an 120V AC input and is for use with the AALBORG Aluminum Flow Controllers.




Ask a question about AALBORG GFC17A-VAL6-A0-3NC-07-SS Mass Flow Controller, 0 to 1 LPM N2, 1/4"

Customer Reviews for the AALBORG GFC17A-VAL6-A0-3NC-07-SS

AALBORG GFC17A-VADL2-E0-07-N2 Mass Flow Controller Offers

Features

  • Zero and span adjustments are accessible from the outside of transmitters
  • Metered gases are divided into two laminar flow paths, one through the primary flow conduit, and the other through a capillary sensor tube
  • Both conduits are designed to ensure laminar flows and there-fore the ratio of their flow rates is constant
  • Two precision temperature sensing windings on the sensor tube are heated, and when flow takes place, gas carries heat from the upstream to the downstream windings
  • Resultant temperature differential is proportional to the change in resistance of the sensor windings
  • Wheatstone bridge design is used to monitor the temperature dependent resistance gradient on the sensor windings which is nearly proportional to the instantaneous rate of flow
  • Output signals of 0 to 5Vdc and 4 to 20mA are generated indicating mass molecular based flow rates of the metered gas
  • The combined gas streams flow through a proportionating electromagnetic valve with an appropriately selected orifice
  • The closed loop control circuit continuously monitors the mass flow
  • output and maintains it at the set flow rate
  • Flow setpoints are controlled either locally or remotely
  • LCD readout built into the top of the transmitters is tilt-able over 90° to provide optimal reading comfort
  • LCD readout is connected to the transducer by a standard modular plug, and is readily removable for remote reading installations
  • Transducers without LCD readout are also available
  • Available with flow ranges from 10 sccm to 1000 l/min
  • Gases are connected by means of 1/4", 3/8" or optional 1/8" compression fittings and 3/4" FNPT fittings
  • Transducer power supply ports are fuse and polarity protected

AALBORG GFC17A-VADL2-E0-07-N2 Specifications

Accuracy ±1.5% f.s. incl. linearity for gas temperatures of 59 to 77°F (15 to 25°C)
Pressures of 5 to 60 psia (0.4 to 4.1 bar)
Repeatability ±0.5% f.s.
Response Time Generally 2s to within ±2% of actual flow rate over 25 to 100% f.s.
Temp. Coefficient 0.15% f.s./°C
Pressure Coefficient 0.01% f.s./psi (0.07 bar)
Optimum Gas Press. 25 psig (1.73 bar)
Max. Gas Pressure 1000 psig (70 bar)
Max. Pressure Diff. GFC17, GFC37: 50 psi (3.4 bar)
GFC47: 40 psi (2.7 bar)
Gas Temperature 41 to 122°F (5 to 50°C)
Leak Integrity 1 x 10-7 ml/sec of helium maximum to the outside environment
Materials Fluid Contact Anodized aluminum, 316 stainless steel, brass & Viton O-rings 
Attitude Sensitivity No greater than ±15° rotation from horizontal to vertical
Output Signals Linear 0-5 Vdc (1000Ω min. load impedance); 4-20 mA (0-500Ω loop resistance); max. noise ±20mV
Command Signals Analog 0-5 Vdc or 4-20 mA for remote set point mode; NPN compatible purge/valve off
Input Power +12 Vdc, 800mA; +24 Vdc, 650mA option
Connections GFC17 & 37: 1/4" compression fittings
GFC47: 3/8" compression fittings
GFC67: 1/2" compression fittings 
Display 3-1/2 digit LCD, 0.5" high characters
Click here for complete specifications on the AALBORG GFC17A-VAL6-A0-3NC-07-SS

What's included with the AALBORG GFC17A-VAL6-A0-3NC-07-SS

  • AALBORG GFC17A-VAL6-A0-3NC-07-SS Mass Flow Controller, 0 to 1 LPM N2, 1/4"

Click on a category to view a selection of compatible accessories with the AALBORG GFC17A-VAL6-A0-3NC-07-SS Mass Flow Controller, 0 to 1 LPM N2, 1/4".

AALBORG PS-GFC-110NA-2 Power Supply for AALBORG Mass Flow Controllers PS-GFC-110NA-2
This US plug is has an 120V AC input and is for use with the AALBORG Aluminum Flow Controllers.




Ask a question about AALBORG GFC17A-VAL6-A0-3NC-07-SS Mass Flow Controller, 0 to 1 LPM N2, 1/4"

Customer Reviews for the AALBORG GFC17A-VAL6-A0-3NC-07-SS

More AALBORG Products

Calibration Lab